Organizations: Division of Radiology and Biomedical Engineering, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan · Department of Computational Diagnostic Radiology and Preventive Medicine, The University of Tokyo Hospital, Tokyo, Japan · Department of Radiology, Kanazawa University Hospital, Ishikawa, Japan · Faculty of Medicine, The University of Tokyo, Tokyo, Japan · Department of Radiology, School of Medicine, Jichi Medical University, Tochigi, Japan · Department of Radiology, The University of Tokyo Hospital, Tokyo, Japan
Purpose: To evaluate whether large language model (LLM)-assisted label cleaning can identify label-report discordance in CT-RATE, a large-scale public chest CT dataset. Materials and Methods: After report-level deduplication, 24,446 unique radiology reports were identified. Twelve reports were excluded from the primary GPT-5.4 analysis because of Microsoft Azure AI Foundry content-safety filtering, leaving 24,434 reports and 439,812 label instances across 18 abnormality categories. GPT-5.4-derived binary labels were generated from report text using structured JSON output and compared with existing CT-RATE labels. Discordant instances were adjudicated by radiologists. In addition, 100 randomly sampled reports were manually annotated to compare CT-RATE labels, individual LLM-derived labels, and multi-LLM majority-vote labels against radiologist-annotated reference labels. Results: Overall agreement between GPT-5.4-derived and CT-RATE labels was 96.4%, with Cohen's kappa of 0.884. Lymphadenopathy showed the lowest agreement and kappa. In discordance review, radiologist adjudication supported GPT-5.4-derived labels in 72 of 97 (74.2%) general discordant instances and 91 of 99 (91.9%) targeted lymphadenopathy discordant instances. Against radiologist-annotated reference labels, multi-LLM majority-vote labels achieved the highest label-macro-averaged F1 score and Cohen's kappa. Conclusion: LLM-assisted label cleaning identified clinically meaningful label-report discordance in CT-RATE and may support scalable quality improvement of public imaging datasets. The cleaned dataset will be made publicly available to support future research.
Interpreting quantitative CT biomarkers, such as organ volume and tissue attenuation, requires large-scale healthy reference distributions. However, creating these is challenging because clinical datasets are often heavily enriched with pathology. Here, we develop an evidence-grounded, cross-verified large language model (LLM) ensemble to filter pathological findings from radiology reports, enabling the construction of pathology-reduced cohorts from over 350,000 CT examinations. Five LLMs, first, flag structure-level abnormality candidates grounded in verbatim report evidence and, second, resolve disagreements via cross-verification. Using distribution-aware generalized additive models for location, scale, and shape, we establish comprehensive whole-body reference charts for 106 anatomical structures (volumes and attenuation) across adulthood, accounting for age, sex, contrast enhancement, and acquisition parameters. Longitudinal analyses reveal structure- and contrast-dependent changes distinct from cross-sectional trends. These resources facilitate covariate-adjusted centile scoring from routine CT, supporting standardized quantitative phenotyping, multi-site imaging studies, and scalable opportunistic screening research.
Christian Wachinger, Bernhard Renger, Christopher Späth +2
Purpose: Accurate CT protocol selection is critical for diagnostic quality and patient safety, yet the current process is manual, time-consuming, and prone to inconsistencies. Prior Machine Learning methods using keywords or bag-of-words lack contextual understanding and perform poorly on rare protocols. We propose a decision support system using large language model (LLM) features to recommend protocols from free-text clinical indications, capturing clinical nuance and phrasing variation for more consistent, efficient selection. Methods: In this REB-approved retrospective study, 285,123 chest CT imaging requests from a large academic medical center (2017-2024) were split into training (228,099, 80%) and held-out test (57,024, 20%) sets. Each request included procedure names, clinical indication, HIS comments, and the selected protocol. Clinical text was embedded using a fine-tuned LLM, Meta's LLaMA-3.1-70B; these features input a logistic regression classifier predicting 18 protocol labels (e.g., PE, LDCT). Results: The pipeline achieved a weighted precision of 0.84, weighted F1-score of 0.81, and overall accuracy of 79% across 18 CT protocols. On 300 independent cases with expert consensus, the LLM reached an overall accuracy of 80% versus 83% for radiologists, with no significant difference (p = 0.263). Performance was comparable across most classes, with the LLM exceeding radiologists for some challenging categories, and entropy analyses indicated more balanced protocol use, suggesting reduced variability. Conclusion: An LLM-based recommendation system can leverage general knowledge from a large natural-text corpus to accurately assign chest CT protocols from free-text imaging requests, and may serve as a viable foundation for protocol recommendation tools where inputs require language understanding.
Errors in radiology reports can adversely affect patient treatment, yet automated report quality assurance remains challenging because errors are often subtle and require domain expertise to detect. Although large language models (LLMs) have recently been proposed for radiology report verification, their ability to detect clinically meaningful errors beyond chest X-ray datasets remains under-explored. To this end, we present the first systematic evaluation of language models for PET/CT report error detection, comparing compact domain-specific models with SOTA open-weight LLMs. We collected 30,633 oncology FDG PET/CT reports from 23 radiologists over 10 years. We trained domain-specific BERT models to detect clinically motivated synthetic reporting errors and evaluated alongside zero-/few-shot Qwen3-32B, Gemma-3-27B and Llama-3.3-70B on a held-out benchmark of 11,500 reports. A 15M-parameter model achieved 94.4% balanced accuracy with a 5.8% false-positive rate, compared with 84.0% for the strongest prompted LLM. Task-specific adaptation of Llama-3.3-70B closed this performance gap (94.4%) but retained substantially greater computational requirements. Our results suggest that domain-specific training matters more than model scale for PET/CT report error detection, supporting compact models as an accurate and computationally efficient approach to automated radiology report quality assurance.
Hermione Warr, Harry Anthony, Lilli J Freischem +3