Multi-zone HVAC control is a spatial decision problem in which indoor thermal evolution and control decisions depend not only on outdoor conditions and internal heat gains but also on zone layout, physical adjacency, and delayed thermal interactions across the building. Recent LLM-based HVAC controllers have shown that prompt-based control is feasible. However, these methods typically rely on task descriptions, observation values, short textual feedback, or unstructured retrieval, which limits their ability to reason about zone coupling, thermal response, and building dynamics. This paper presents a thermodynamics-aware LLM control framework for a five-zone EnergyPlus building simulation. The controller is grounded in a physics-informed spatial knowledge graph derived from Brick-style building semantics and linked with recent interaction history. At each control step, the model receives the current building state, graph-structured spatial context, and recent environment-controller history, enabling it to make decisions that reflect both building structure and short-term thermal evolution. We evaluate the framework against standard control baselines and several LLM-based alternatives. Results show that the proposed approach achieves the best overall energy-comfort trade-off and the lowest PMV violation while maintaining energy-efficient operation.
Optimizing HVAC (Heating, Ventilation and Air Conditioning) can enhance a building's energy efficiency while providing comfort levels for its occupants. Using conventional control systems to maintain HVAC functions is often difficult because of the nonlinear characteristics of a building envelope as it experiences stochastic load variations over time. This paper presents a new approach to optimizing HVAC systems through the use of Deep Reinforcement Learning (DRL) algorithms and the Proximal Policy Optimization (PPO) algorithm implemented in a custom Python performance environment. The DRL system uses a second order resistor-capacitor thermal model and an integrated dynamic mass balance of CO2 to replicate the complex physics associated with buildings. One major innovation of this study is a "Hierarchical Flow Logic," which provides the means to ensure that indoor air quality (IAQ) is maintained by overriding the accepted actions of the agent that cause CO2 to exceed 1000 ppm. In addition, an enthalpy-based economiser is used to create free cooling from the outdoor environment. The experimental data shows that compared to PID controllers tuned by GA or traditional On-Off controls, a PPO agent has better temperature stability and energy efficiency overall. An end-to-end pipeline provides an avenue for robust and generalized solutions to help implement smart building energy management within the context of real hardware implementation.
This paper proposes a contextual quality-diversity evolutionary reinforcement-learning controller, CQD-ERL, for the supervisory control of a tropical, water-cooled chiller plant and its associated air side. Rather than converging to a single scalarised policy, the controller maintains a product archive of specialised policies indexed jointly by a data- driven operating context, a cluster of daily weather and load regime, and a context-invariant behaviour descriptor, filled by a gradient-free evolutionary operator and a soft-actor-critic policy-gradient operator that share one replay buffer. Every action is filtered through a deterministic safety shield before execution. The controller is trained on a two-tier reduced-order environment representing the latent load, cooling-tower approach and humidity constraints of a Singapore commercial building, and is evaluated over a full annual backtest against an ASHRAE Guideline 36 baseline.
Buildings are expected to shift cooling loads in response to grid conditions. Thermal energy storage (TES) enables this shift, but scheduling it well requires planning hours ahead under storage constraints. Model predictive control (MPC) and reinforcement learning are difficult to scale across buildings. This study instead adapts an open-weight reasoning model through reinforcement learning with verifiable rewards (RLVR). We convert exact offline dynamic-programming (DP) action values into dense rewards for every candidate action. Using only 30 training prompts, reinforcement fine-tuning (RFT) trains the model as an upper-level scheduler that outputs hourly heat-pump setpoints from text-based states and forecasts. Evaluation uses a deliberately simple office-building TES benchmark where exact DP is tractable and the optimum is known. RFT reduces the open-weight model's emissions from 70.5 to 61.2 kg-CO2, close to the DP optimum of 60.8 kg-CO2. GPT-5 nearly matches DP and MPC without task-specific training, while GPT-4o, a non-reasoning LLM, produces higher emissions than the no-storage baseline, so inference-time reasoning appears important. Trace analysis shows that RFT mainly stabilizes observable planning patterns (candidate comparison, look-ahead, and feasibility checking) rather than creating a new strategy. Robustness and generalization tests clarify what transfers: the reinforced planning patterns persist under forecast errors and an unseen TES condition and carry over to a battery task, but its different structure limits the gains. DP-based verifiable rewards offer a practical way to adapt open-weight reasoning models to building storage scheduling. These results motivate higher-fidelity tests of whole-building control and scalable verifiers for city-scale energy management.