cs.CVJun 30, 2026

Temporal Training Strategies for Left Atrium and Left Atrial Appendage Segmentation in Dynamic Contrast 4DCT

Authors: David Montalvo-GarcíaLauren SeveranceElliot R. McVeighMaría J. Ledesma-Carbayo

Abstract

Dynamic contrast-enhanced cardiac CT enables time-resolved analysis of contrast filling and washout in the left atrium (LA) and left atrial appendage (LAA), with potential applications for assessing blood stasis in atrial fibrillation (AF). Accurate segmentation across all frames is required for such analysis but is challenging due to large temporal contrast variations and the use of a single annotation per registered sequence. This creates a trade-off between training for robustness and limiting label noise. In this study, we investigate how temporal training-set design affects nnUNet-based segmentation of the LA and LAA in dynamic 4DCT. We compare training using a minimal two-frame dataset reflecting standard clinical practice, a physiologically selected subset of frames, and the full 27-frame sequence. We further evaluate the impact of foreground-based normalization. Training with all frames yielded the best performance in early low-contrast phases. However, the physiologically selected subset achieved comparable performance from the filling phase onward. Applying normalization parameters derived from the full dataset improved performance of reduced datasets in low-contrast frames, but did not fully close the gap. These findings highlight the importance of temporal diversity in training data for robust segmentation in dynamic CT, while indicating that carefully selected frame subsets may provide an effective trade-off between performance and efficiency for downstream applications.

Explore similar work

Aug 12, 2026cs.CV

A Neighborhood Attention Transformer Network for Enhanced 3D Segmentation of the Left Anterior Descending Artery

Background: Accurate segmentation of the Left Anterior Descending (LAD) artery in 3D free-breathing, non-contrast CT is critical for cardiac dose sparing in thoracic radiotherapy. The LAD is extremely small, has poor soft-tissue contrast, and varies substantially across patients; even manual contours show limited inter-observer agreement, underscoring the ambiguity of the vessel boundaries. Purpose: To develop a transformer-based framework that improves LAD delineation in low-contrast, imbalanced CT through local-global context modeling and uncertainty-guided optimization. Methods: We propose NA-UNETR, a 3D transformer-based segmentation model whose Neighborhood Attention (NA) and Dilated NA (DiNA) blocks jointly capture fine structural detail and long-range context. Given the scarcity of annotated LAD data, the model is pretrained on 1,000 CTA volumes of general coronary anatomy and fine-tuned with LoRA-based parameter-efficient adaptation on 20 free-breathing institutional CT scans. A composite Dice-Focal and Hausdorff loss, dynamically balanced via homoscedastic uncertainty, improves overlap and boundary accuracy. Results: NA-UNETR reached 45.64% Dice, 38.16 mm HD95, and 10.01 mm ASD, improving Dice by 3.10 percentage points over nnU-Net and reducing HD95 by 2.96 mm relative to Swin UNETR, with the strongest boundary accuracy among all models and improved centerline stability. On ImageCAS it achieved 79.49% Dice, 8.89 mm HD95, and 1.02 mm ASD. Ablations confirmed that residual blocks, variable kernels, and uncertainty-weighted loss each contributed. Conclusions: NA-UNETR balances local precision and global context for thin, low-contrast LAD structures, offering a computationally efficient framework for substructure-level cardiac segmentation in radiotherapy planning.
Rafi Ibn Sultan, Chengyin Li, Yiannos Demetriou +6
Jun 22, 2026eess.IV

Promise and challenges of heart chamber segmentation from non-contrast CT scans using contrastive unpaired image translation: a feasibility study

Purpose: To evaluate the feasibility and challenges of heart chamber segmentation from non-contrast CT scans using contrastive unpaired image translation and deep learning-based segmentation. Approach: We developed ChameleonNet, a framework utilizing the Contrastive Unpaired Translation (CUT) network with decoupled contrastive learning (DCL) loss to synthesize non-contrast CT from contrast CT scans. Using annotations of four heart chambers (left atrium (LA), left ventricle (LV), right atrium (RA), and right ventricle (RV)) from contrast scans, we trained a Hausdorff distance loss-enhanced nnU-Net on synthesized non-contrast images. The translation model was trained with 35,538 contrast-enhanced and 37,197 non-contrast CT slices. The segmentation model was trained with 292 synthesized non-contrast scans. Performance was evaluated using Dice similarity coefficient (DSC) and 95th Hausdorff distance (HD95) on 36 synthesized non-contrast scans, and volume agreement on 36 real non-contrast CT scans was assessed using Pearson correlation, mean absolute percentage error (MAPE), and mean percentage error (MPE). Results: The segmentation model achieved DSC of 0.94 (0.01), 0.91 (0.04), 0.92 (0.03), 0.93 (0.02), and HD95 of 3.63 (1.49), 5.74 (4.08), 5.18 (1.77), 5.51 (3.21) mm on synthesized non-contrast images for LA, LV, RA, and RV, respectively. On real non-contrast CT scans, Pearson correlations were 0.93, 0.82, 0.87, and 0.89 (all p<0.001), with MAPE ranging from 9.22% to 20.79%, and MPE ranging from -12.52% to 4.67%. Conclusions: ChameleonNet demonstrated feasibility for heart chamber segmentation from non-contrast CT without manual non-contrast annotations. However, volume errors, particularly for LV and RV, indicate that further refinement and validation are needed before clinical use.
Jing Wang, Tong Yu, Hao-En Lu +5
Jun 30, 2026cs.CV

Self-Supervised Temporal Regularization for Landmark-Based Cardiac Segmentation with Automatic AHA Regional Mapping

Graph-based cardiac segmentation with implicit anatomical correspondences provides topological guarantees and population-level analysis capabilities, but models trained on independent frames of image sequences exhibit temporal discontinuities that affect reliable clinical measurements, particularly in cardiac ultrasound. In this work, we introduce self-supervised temporal regularization as a post-training refinement stage that exploits the temporal coherence in image sequences to enforce consistent cardiac segmentation and motion estimation over time, without requiring per-frame annotations. By penalizing velocity and acceleration discontinuities across consecutive frames, our method achieves temporally consistent segmentations while maintaining the learned anatomical correspondences. We further leverage these correspondences to automatically map landmarks to the AHA 17-segment clinical standard, enabling standardized regional assessment and detection of pathological myocardial motion patterns. Validation on CAMUS dataset demonstrates the clinical utility of combining temporal consistency with automatic regional mapping. The code is publicly available at https://github.com/david-montalvoo/MaskHybridGNet-TempReg
David Montalvo-García, Nicolás Gaggion, María J. Ledesma-Carbayo +1