cs.LGJul 4, 2026

Conservative Subject Invariant EMG-based Gesture Recognition

Authors: Hamed RafieiAli Mousavi

Abstract

Cross-subject generalization remains a fundamental challenge in surface electromyography (sEMG)-based gesture recognition. Although deep learning methods have improved within-subject performance, they often rely on subject-specific data and struggle to balance invariance and discriminability. In this work, we propose a conservative multi-objective learning framework for subject-invariant sEMG gesture recognition. The proposed model adopts a multi-head architecture that jointly optimizes gesture classification, adversarial subject confusion through gradient reversal, and triplet-based metric learning to encourage discriminative and subject-invariant representations. To improve optimization stability, a Lipschitz-inspired adaptive weighting mechanism is introduced to dynamically balance the auxiliary objectives according to their relative magnitudes during training. The proposed method is evaluated on two benchmark datasets: UCI EMG (36 subjects, 6 gestures) and NinaPro DB5 (10 subjects, 10 gestures). On the UCI EMG dataset, the method achieves 84.48% accuracy compared to 78.2% reported by state-of-the-art methods. On NinaPro DB5, it achieves 61.44% accuracy versus 41.30%, corresponding to a 49% relative improvement. In addition, the proposed framework reduces cross-subject prediction variance and produces more structured latent representations. These results indicate that jointly enforcing invariance and discriminability through adaptive multi-objective optimization leads to more stable training and improved cross-subject generalization in sEMG-based gesture recognition systems.

Explore similar work

Jun 30, 2026eess.SP

PGUDA: Pressure-Guided Unsupervised Domain Adaptation with Cross-Modal Knowledge Distillation for sEMG-Based Gesture Recognition

Surface electromyography (sEMG)-based gesture recognition has emerged as a promising technology for natural human-computer interaction. However, its practical deployment remains challenging due to severe performance degradation caused by feature distribution discrepancies across different subjects and recording sessions. Although domain adaptation (DA) techniques are commonly employed to mitigate such discrepancies, conventional methods often struggle to effectively aligning sEMG features, primarily due to their inherent stochasticity and the scarcity of labeled data. To address these limitations, this paper proposes a novel Pressure-Guided Unsupervised Domain Adaptation (PGUDA) framework, which leverages the robustness and stability of pressure signals to introduce a cross-modal knowledge distillation strategy that transfers consistent physical semantics across modalities. Specifically, a teacher network trained on pressure signals guides an sEMG student network on unlabeled target domains, thereby regularizing the representation learning process with transferable and modality-invariant knowledge. Extensive experiments conducted on a self-collected multimodal dataset involving eleven subjects validate the effectiveness of the proposed PGUDA framework. The results demonstrate that our proposed PGUDA achieves leading performance in both cross-subject and cross-session classification tasks, achieving average accuracies of 58.08% and substantially outperforming existing DA approaches. Notably, PGUDA exhibits remarkable label efficiency: it attains classification accuracy comparable to fully supervised benchmarks while requiring only 5% of labeled data for teacher network training. This framework offers a robust and data-efficient solution that can significantly reduce the calibration burden in practical sEMG-based gesture recognition systems.
Yurui Liu, Xiao-Cong Zhong, Qisong Wang +3
Jul 24, 2026cs.LG

Multimodal Surface EMG Hand Gesture Recognition Using Query-Based Transformers for Prosthetic Control

Hand gesture recognition via surface electromyography (sEMG) is fundamental to prosthetic control. In this field, deep learning approaches have become the gold standard. However, current architectures struggle to scale; model performance typically decreases as the number of hand movements increases. Performance degradation is tied to the increased statistical complexity of decoding expanded gesture sets and compounded by the limitations of state-of-the-art methods, which primarily rely on low-latency unimodal convolutional architectures. Convolutions operate locally, limiting model's ability to capture long-range sequential patterns. Unimodal setups cannot leverage complementary information from coordinated signals characterizing movement execution, such as inertial and eye-tracking data. These limitations motivate architectures that integrate local and global features across multimodal physiological sequences. To bridge this gap, this study introduces EMG-CrossFormer, an end-to-end hybrid convolutional-transformer for seamless multimodal integration. EMG-CrossFormer combines representations from an arbitrary number of unimodal encoders through cascaded cross-attention fusion layers, and decodes the fused representations using learnable gesture queries. EMG-CrossFormer was evaluated on four NinaPro datasets (DB2, DB3, DB7, and DB10) and benchmarked against six state-of-the-art models using an increasing number of modalities. Using only sEMG, EMG-CrossFormer achieved mean accuracies of 72.33%, 52.48%, 79.16%, and 73.49% on DB2, DB3, DB7, and DB10, respectively. Incorporating inertial signals improved performance to 90.66%, 80.40%, 92.79%, and 92.06%. These results show that joint local-global feature modeling improves sEMG-only decoding and that multimodal fusion substantially amplifies this benefit, underscoring the value of both design principles for complex hand gesture recognition.
Federico Del Pup, Elisa Tentori, Manfredo Atzori
Jan 7, 2026cs.LG

Lightweight Test-Time Adaptation for EMG-Based Gesture Recognition

Reliable long-term decoding of gestures from surface electromyography (EMG) is hindered by signal drift caused by electrode displacement, muscle fatigue, and/or posture changes. Although modern models achieve high intra-session accuracy, their performance often degrades substantially across recording sessions. Existing approaches to mitigate this problem typically rely on large training datasets or computationally intensive pipelines that are unsuitable for energy-efficient wearable devices. We propose a lightweight test-time adaptation framework for EMG decoding. The framework includes three complementary adaptation strategies: (i) causal adaptive batch normalization for online statistical alignment, (ii) Gaussian Mixture Model alignment with experience replay to mitigate forgetting, and (iii) meta-learning for rapid few-shot calibration. We evaluate these methods on the multi-session NinaPro DB6 dataset. All approaches substantially improve inter-session robustness relative to a non-adaptive baseline while maintaining low computational overhead. Replay-regularized statistical alignment provides the most stable adaptation under limited data, while meta-learning achieves the highest accuracy when sparse calibration labels are available. Overall, our self-supervised test-time adaptation methods reach up to 82% inter-session accuracy, significantly improving upon prior approaches while maintaining resource-efficient operation. These results demonstrate that lightweight test-time adaptation can enable robust, long-term EMG decoding for wearable or prosthetic applications.
Nia Touko, Matthew O A Ellis, Cristiano Capone +3