cs.CVJul 6, 2026

CenSynCMB: Centre Maps and Physics-Guided Synthesis for Microbleed Detection

Authors: Lucas HeHanyuan ZhangKrinos LiAdama Fatima SaccohSilvia IngalaRafael RehwaldMarleen de BruijneFrederik Barkhof+2 more

Abstract

Cerebral microbleeds (CMBs) are MRI markers of small vessel disease and the microbleed component of amyloid related imaging abnormalities (ARIA-H), but their small size, sparsity, and similarity to vessels, calcification-like foci, and artefacts make automated detection difficult. We propose CenSynCMB, a centre-guided and mimic-aware framework combining a 3D Attention U-Net, auxiliary centre-map supervision, false-negative-driven reweighting, and fold-wise physics-guided synthesis of positive CMBs and labelled hard negatives. Synthetic data expose the detector to compact lesions and common mimics without validation or test leakage. On VALDO Task 2, CenSynCMB achieved the best local-comparison lesion-level F1 (74.3%, p = 0.020); on external AIBL SWI, it achieved the highest local-comparison recall (88.5%, p = 0.0058) and F1 (65.0%, p = 0.0016). Together, these results support scalable CMB candidate extraction in large, unlabelled MRI cohorts, while highlighting cohort-specific calibration as the next step toward reliable burden estimation.

Explore similar work

Jul 8, 2026cs.CV

AA-ViT: Anatomically Aware Vision Transformer with Structural and Frequency Guidance for Contrast Enhanced Brain MRI Synthesis

Accurate tumour localization and diagnosis is a critical component of clinical care for brain cancers. Magnetic Resonance Imaging (MRI) is the most commonly used imaging modality due to its superior soft-tissue contrast. However, standard MRI often exhibits limited contrast and imaging artifacts, which necessitates the use of contrast agents to enhance lesion visibility. The administration of chemical contrast agents is not always feasible and may be contraindicated in patients with renal impairment or other health conditions. As a result, developing accurate and non-invasive contrast enhanced MRI (CEMRI) synthesis methods has clinical importance. In recent years, numerous approaches for CEMRI synthesis have been proposed, predominantly relying on generative artificial intelligence models. While these methods demonstrate promising performance, their dependence on implicit feature learning often limits their ability to preserve anatomical boundaries and tumour-specific fine structures. To address these challenges, we propose an anatomically aware frequency-and-structure-guided vision transformer (AA-ViT), for CEMRI synthesis using pre-contrast MRI modalities (T1, T2, and FLAIR). Experiments on the BraTS 2021 dataset demonstrate that the proposed method preserves anatomical and lesion boundaries, achieving higher PSNR and SSIM than state-of-the-art approaches. Clinical evaluation by three neuroradiologists and a neurosurgeon on 19 randomly selected cases across diverse gliomas yielded a mean score of 3.94/5, providing preliminary clinical validation rarely seen in prior studies. Synthetic post-contrast scans from our model could lower scanning costs, shorten imaging time, and avoid the potential risks of using gadolinium-based contrast agents.
Talha Meraj, Tom Flannery, Charlie Cummins +6
Jun 5, 2026eess.IV

Impact of Synthetic Lesional MR Images in Automated Focal Cortical Dysplasia Detection in Low-Data Scenarios

Background and Purpose: Automated detection of focal cortical dysplasia (FCD) requires large volumes of voxelwise lesion-delineated MRI data, which are difficult to acquire. This study aims to generate synthetic MRI data exhibiting FCD, assess their realism, and evaluate their impact on automated FCD detection, particularly in reducing the need for manual annotations. Methods: T1-weighted (T1w) and T2-weighted Fluid-Attenuated Inversion Recovery (FLAIR) MRI scans from 131 FCD patients and 90 healthy controls from multiple (3) sites were retrospectively studied. Synthetic MRIs were generated by conditioning a generative network on binary FCD masks. Two neuroradiologists identified real images from a random set of 14 real and 14 synthetic scans. Three nnU-Net models were trained to detect FCD using: (i) real-only (35 FCD / 35 controls), (ii) real (35 FCD / 35 controls) plus synthetic augmentation, and (iii) expanded real data (70 FCD / 70 controls). Results: Experts showed limited ability to distinguish real from synthetic images, with classification accuracy of 60% for T1w and 70% for FLAIR (inter-rater agreement kappa = 0.86). Augmenting automated FCD detection with synthetic data increased sensitivity by 8.14% (p = 0.12) and improved model confidence at true lesion sites (0.83 +/- 0.11 to 0.89 +/- 0.12; p = 0.02). The expanded real-data model further improved sensitivity to 73.8% (p < 0.001) and confidence to 0.90 +/- 0.14 (p = 0.01). Conclusion: Conditional generative networks can generate realistic synthetic FCD-MRIs, reducing labeled data needs by approximately 20% while maintaining equivalent sensitivity. Equivalent amounts of real data, when available, remain more effective than synthetic augmentation.
Prabhjot Kaur, Hakim Ouaalam, Sedat Kandemirli +2
Jun 13, 2026cs.CV

Lesion-DDPM: Lesion-Enhanced 3D Diffusion for MS MRI Synthesis

3D FLAIR MRI is widely recommended as one of the standard MRI sequences for brain imaging in multiple sclerosis (MS), but publicly available MS datasets remain relatively small and vary across scanners, acquisition protocols, and lesion patterns. This scarcity and variability hinder the development of robust neuroimaging machine learning models and are particularly challenging for generative models that aim to synthesize images while preserving small, sparse lesions. We propose Lesion-DDPM, a 3D conditional diffusion framework for lesion-aware FLAIR synthesis that incorporates multi-level anatomical mask injection together with a lesion-weighted reconstruction loss to emphasize lesion voxels while maintaining global brain structure. Using a curated subset of the MSLesSeg dataset, we compare Lesion-DDPM with representative state-of-the-art GAN- and diffusion-based models, assessing both image-generation metrics and downstream 3D U-Net segmentation. In our experiments, Lesion-DDPM achieved the lowest lesion-region reconstruction error among all methods. In a downstream 3D U-Net lesion segmentation task, a model trained only on Lesion-DDPM-generated scans and evaluated on real MRIs reached a Dice score of 0.616 compared with 0.569 for the best competing synthetic dataset. When Lesion-DDPM images were added to the real training set, the Dice score further increased to 0.685.
Weidong Zhang, Yongchan Jung, Shafayat Mowla Anik +5