cs.CVJul 7, 2026

Harrison.Rad 1.5 Technical Report: A radiology foundation model that can draft reports from images, priors and clinical context

Authors: Suneeta MallVladimir NekrasovAshnil KumarSajith KarunasenaAiden NibaliAlix BirdMateo Diaz ShineJarrel Seah

Abstract

Imaging demand is growing faster than the radiology workforce can expand, and reporting backlogs cannot be resolved through training and recruitment alone. The most direct opportunity is reducing the time and effort radiologists spend producing reports, a task that requires interpreting images, integrating clinical history and prior studies, and drafting structured findings. We present Harrison.Rad 1.5 (HR1.5), a radiology-specific multimodal large language model that accepts interleaved text and visual inputs and generates structured and unstructured text across plain-film radiology, spanning computed radiography, chest, musculoskeletal, abdominal, spine, and pelvic x-rays, and mammography. HR1.5 is trained through a three-stage pipeline: domain adaptation of a base language model on radiology reports, contrastive vision-encoder training with curriculum-based hard negatives on ~6 million image-report instances, and visual-question-answering fine-tuning on multi-turn conversations. We evaluate it with a Findings-Diagnosis scoring framework that extends RadGraph-XL entity extraction with ontology-based synonym matching and polarity-contradiction detection, benchmarked on RadBench, a simulated FRCR 2B Short Case examination scored against Angoff-method thresholds, ReXGradient, and internal multi-modality datasets. HR1.5 is the only system evaluated to meet the simulated FRCR passing standard and achieves the highest accuracy on closed-format clinical questions, across anatomical regions, on internal multi-body-part and mammography reporting, and on the primary clinically-aligned score for public chest reporting. We further examine explainability and model behaviour, including question-sensitive Grad-CAM heatmaps, attention analysis, and confidence estimation, to support responsible future evaluation toward clinical use, and a framework for clinically grounded assessment of report quality.

Explore similar work

Jul 4, 2026cs.CV

CogRad: A Cognitively-Inspired Multi-Agent Framework for Radiology Report Generation

Automated radiology report generation (RRG) can ease radiologist workload, yet most existing systems produce a report in a single forward pass, with no mechanism to check a claim against the image or revisit a finding once stated. We present CogRad, a cognitively inspired multi-agent framework that structures generation around four stages of a radiologist's reading process. A Scout agent discovers anatomical regions directly from image patches via slot attention and assigns region and disease-level triage scores; an Investigator agent concentrates representational capacity on the regions Scout flags as suspicious; a Writer agent compiles these signals into a disease gated visual prefix for a large language model; and a Verifier agent supervises training with a visual entailment loss and, at inference, re-examines its own draft sentence by sentence, regenerating any report it judges insufficiently grounded. On CheXpert Plus, CogRad attains a BLEU-4 of 0.316 and a CIDEr of 0.322, the best scores among the methods we compare against. On IU X-Ray, it attains a BLEU-4 of 0.201 and a CIDEr of 0.724, leading every baseline on every standard NLG metric. We further evaluate CogRad with RadGraph F1, CheXbert F1, and a hallucination analysis to assess clinical accuracy beyond standard text-overlap metrics, complemented by ablation studies and Grad-CAM-based visualizations that characterize each agent's contribution and the model's visual grounding.
Saif Ur Rehman Khan, Hasaan Maqsood, Sebastian Vollmer +2
Mar 11, 2024cs.CV

Multimodal Large Language Model driven Radiology Report Generation with Clinical Knowledge Enhancement

Radiology report generation (RRG) has attracted significant attention due to its potential to reduce the workload of radiologists. The performance of current RRG approaches remains unsatisfactory against clinical standards. This paper introduces a novel RRG method, MLLM-RRG, that integrates multimodal large language models (MLLMs) with various types of clinical knowledge to generate accurate and comprehensive chest X-ray reports. Our method first designs a referring anatomical feature extractor that leverages anatomical knowledge to analyze different regions of the chest X-ray image and extract visual features without explicitly detecting regions. Next, based on the MLLM's decoder, we develop a multimodal report generator that leverages multimodal prompts constructed from dedicated visual features and textual instructions to produce the radiology report in an auto-regressive way. Finally, we introduce a disease-oriented clinical classification and alignment scheme in a multi-task learning manner to leverage disease knowledge to better preserve the clinical relevance among the generated reports. Once the model is trained, we also introduce a novel clinical quality reinforcement learning strategy to enhance the MLLM with report knowledge, further refining the tones of the generated reports towards radiologists. Extensive experiments on the MIMIC-CXR and IU X-Ray datasets demonstrate the superiority of our method over the state of the art. Our codes will be available at https://github.com/viscom-tongji/MLLM-RRG.
Miaojing Shi, Tianyu Cen, Zijie Yue +3
Apr 30, 2026cs.CV

RIHA: Report-Image Hierarchical Alignment for Radiology Report Generation

Radiology report generation (RRG) has emerged as a promising approach to alleviate radiologists' workload and reduce human errors by automatically generating diagnostic reports from medical images. A key challenge in RRG is achieving fine-grained alignment between complex visual features and the hierarchical structure of long-form radiology reports. Although recent methods have improved image-text representation learning, they often treat reports as flat sequences, overlooking their structured sections and semantic hierarchies. This simplification hinders precise cross-modal alignment and weakens RRG accuracy. To address this challenge, we propose RIHA (Report-Image Hierarchical Alignment Transformer), a novel end-to-end framework that performs multi-level alignment between radiological images and their corresponding reports across paragraph, sentence, and word levels. This hierarchical alignment enables more precise cross-modal mapping, essential for capturing the nuanced semantics embedded in clinical narratives. Specifically, RIHA introduces a Visual Feature Pyramid (VFP) to extract multi-scale visual features and a Text Feature Pyramid (TFP) to represent multi-granularity textual structures. These components are integrated through a Cross-modal Hierarchical Alignment (CHA) module, leveraging optimal transport to effectively align visual and textual features across various levels. Furthermore, we incorporate Relative Positional Encoding (RPE) into the decoder to model spatial and semantic relationships among tokens, enhancing the token-level alignment between visual features and generated text. Extensive experiments on two benchmark chest X-ray datasets, IU-Xray and MIMIC-CXR, demonstrate that RIHA outperforms existing state-of-the-art models in both natural language generation and clinical efficacy metrics.
Yucheng Chen, Yang Yu, Yufei Shi +3