cs.ROJul 10, 2026

Vascular Geometry Characterization for AI-Based Endovascular Navigation

Authors: Han-Ru WuHarry RobertshawLisa Dwyer-JoyceThomas C BoothAlejandro Granados

Abstract

Mechanical thrombectomy (MT) is a time-critical intervention for acute ischemic stroke; however, access remains limited due to a shortage of neuroradiologists and specialized centers. Reinforcement learning (RL) offers potential to automate endovascular navigation and improve accessibility, yet current models lack standardized frameworks to assess navigation difficulty for model training and evaluation. This study aims to identify vascular metrics associated with navigation difficulty and to develop an automated pipeline for quantitative vascular feature extraction, enabling future complexity grading. Vascular trees were segmented from computed tomography angiograms from 61 patients, and vascular metrics including aortic arch type, presence of bovine arch, vessel length, tortuosity, take-off angle, number of reverse curves, were measured using a custom pipeline. A Soft Actor-Critic RL algorithm was used for 120 s autonomous navigation. Outcomes were analyzed using both mixed effects linear and logistic regression. On the left side, the presence of a bovine arch and aortic arch type II/III increased navigation time by 30.19 s and 37.92 s, respectively, while greater tortuosity (\b{eta} = 118.20) further prolonged the procedure and reduced success probability. On the right side, type II/III arches extended procedure time by 45.94 s, while each additional reverse curve was associated with 3.96 s longer navigation time and lower probability of success. These findings demonstrate for the first time that MT agent navigation difficulty is strongly influenced by vascular geometry. The proposed automated pipeline enables objective and quantitative characterization of vascular features, providing a foundation for future development of standardized complexity grading and RL model evaluation, without aiming to demonstrate clinically generalizable autonomous navigation.

Explore similar work

Apr 22, 2026cs.RO

Toward Safe Autonomous Robotic Endovascular Interventions using World Models

Autonomous mechanical thrombectomy (MT) presents substantial challenges due to highly variable vascular geometries and the requirements for accurate, real-time control. While reinforcement learning (RL) has emerged as a promising paradigm for the automation of endovascular navigation, existing approaches often show limited robustness when faced with diverse patient anatomies or extended navigation horizons. In this work, we investigate a world-model-based framework for autonomous endovascular navigation built on TD-MPC2, a model-based RL method that integrates planning and learned dynamics. We evaluate a TD-MPC2 agent trained on multiple navigation tasks across hold out patient-specific vasculatures and benchmark its performance against the state-of-the-art Soft Actor-Critic (SAC) algorithm agent. Both approaches are further validated in vitro using patient-specific vascular phantoms under fluoroscopic guidance. In simulation, TD-MPC2 demonstrates a significantly higher mean success rate than SAC (58% vs. 36%, p < 0.001), and mean tip contact forces of 0.15 N, well below the proposed 1.5 N vessel rupture threshold. Mean success rates for TD-MPC2 (68%) were comparable to SAC (60%) in vitro, but TD-MPC2 achieved superior path ratios (p = 0.017) at the cost of longer procedure times (p < 0.001). Together, these results provide the first demonstration of autonomous MT navigation validated across both hold out in silico data and fluoroscopy-guided in vitro experiments, highlighting the promise of world models for safe and generalizable AI-assisted endovascular interventions.
Harry Robertshaw, Nikola Fischer, Han-Ru Wu +6
Jul 10, 2025eess.IV

ArteryX: A Reliable End-to-End Toolbox for Standardized Intracranial Artery Feature Extraction from 3D TOF-MRA

Cerebrovascular research heavily relies on quantitative analysis of intracranial arteries from time-of-flight magnetic resonance angiography, yet existing processing pipelines remain limited by inconsistent artery labeling and a high manual correction burden. We present ArteryX, a toolbox for extracting features that standardizes artery classification across proximal and distal vascular territories. It integrates segmentation handling, isotropic processing, vessel-fused graph construction, and constrained landmark-based classification within a unified artery-specific feature reporting and reproducible workflow. The toolbox extracts morphological, topological, and complexity features including total length, mean radius, volume, surface area, branch count, tortuosity, and fractal dimensionality for standardized artery-segments. Test-and-validation were performed using three complementary datasets: (1)TopBrain-Challenge benchmarking with annotated arteries, (2)synthetic known-reference validation, and (3)exploratory in-vivo cohort of cerebral small vessel disease. In TopBrain analyses, ArteryX with supervised nnUnet segmentation showed minimal bias, while iCafe showed the highest bias and a large limit-of-agreement. ArteryX consistently demonstrated robust downstream quantification performance across segmentation sources (unsupervised/supervised). Agreement analyses showed minimal bias for radius and good sensitivity of extent-dependent metrics throughout the noisier segmentations compared to the state-of-the-art iCafe-toolbox. Furthermore, a stage-wise human-in-the-loop protocol showed lower intervention time than iCafe. In an in-vivo-cohort (48CSVD+, 20CSVD-), ArteryX-derived distal and territory-level features showed group-level differences, not evident with iCafe. To facilitate adoption-and-reproducibility, ArteryX is designed with versioned builds, tutorials, and documentation.
Abrar Faiyaz, Nhat Hoang, Giovanni Schifitto +1
May 14, 2026cs.CV

Towards Real-Time Autonomous Navigation: Transformer-Based Catheter Tip Tracking in Fluoroscopy

Purpose: Mechanical thrombectomy (MT) improves stroke outcomes, but is limited by a lack of local treatment access. Widespread distribution of reinforcement learning (RL)-based robotic systems can be used to alleviate this challenge through autonomous navigation, but current RL methods require live device tip coordinate tracking to function. This paper aims to develop and evaluate a real-time catheter tip tracking pipeline under fluoroscopy, addressing challenges such as low contrast, noise, and device occlusion. Methods: A multi-threaded pipeline was designed, incorporating frame reading, preprocessing, inference, and post-processing. Deep learning segmentation models, including U-Net, U-Net+Transformer, and SegFormer, were trained and benchmarked using two-class and three-class formulations. Post-processing involved two-step component filtering, one-pixel medial skeletonization, and greedy arc-length path following with contour fall-back. Results: On manually-labeled moderate complexity fluoroscopic video data, the two-class SegFormer achieved a mean absolute error of 4.44 mm, outperforming U-Net (4.60 mm), U-Net+Transformer (6.20 mm) and all three-class models (5.19-7.74 mm). On segmentation benchmarks, the system exceeded state-of-the-art CathAction results with improvements of up to +5% in Dice scores for three-segmentation. Conclusion: The results demonstrate that the proposed multi-threaded tracking framework maintains stable performance under challenging imaging conditions, outperforming prior benchmarks, while providing a reliable and efficient foundation for RL-based autonomous MT navigation.
Harry Robertshaw, Yanghe Hao, Weiyuan Deng +6