cs.CVJul 13, 2026

FlowPET: Physics-Informed Symplectic Flow Matching for Low-Count PET Reconstruction

Authors: Zheng ZhangHao TangYingying HuZhanli HuJing Qin

Abstract

Low-count Positron Emission Tomography (PET) reconstruction is severely hindered by the dissipative nature of prevailing generative models, where the inherent phase-space contraction leads to the numerical extinction (``wash-out'') of weak but diagnostically critical lesion signals. To overcome this geometric limitation, we propose \textbf{FlowPET}, a physics-informed framework that reformulates reconstruction as volume-preserving transport in a symplectic phase space. By parameterizing the posterior dynamics via a Separable Hamiltonian System, our approach guarantees a divergence-free vector field by construction, theoretically immunizing weak signals against probability mass collapse. To steer this conservative flow, we introduce conjugate boundary conditions based on the Range-Null space decomposition of the PET operator; this strictly enforces data consistency in the range space while confining stochastic uncertainty injection to the unobserved null space. We train the model via symplectic flow matching and perform inference using a symplectic leapfrog integrator. Extensive experiments on BrainWeb, clinical pediatric, and UDPET datasets demonstrate that \textbf{FlowPET} not only surpasses state-of-the-art deterministic and stochastic baselines in SSIM and PSNR but, more crucially, exhibits superior recovery of low-contrast lesions. The results confirm that imposing Hamiltonian structural constraints offers a robust geometric safeguard for medical inverse problems in high-noise regimes.

Explore similar work

May 5, 2026cs.LG

PerFlow: Physics-Embedded Rectified Flow for Efficient Reconstruction and Uncertainty Quantification of Spatiotemporal Dynamics

Reconstructing PDE-governed fields from sparse and irregular measurements is challenging due to their ill-posed nature. Deterministic surrogates are trained on dense fields that struggle with limited measurements and uncertainty quantification. Generative models, by learning distributions over spatiotemporal fields, can better handle sparsity and uncertainty. However, existing generative approaches enforce data consistency and PDE constraints simultaneously via sampling-time gradient guidance, resulting in slow and unstable inference. To this end, we propose PerFlow, a Physics-embedded rectified Flow for efficient sparse reconstruction and uncertainty quantification of spatiotemporal dynamics. PerFlow decouples observation conditioning from physics enforcement, performing guidance-free conditioning by feeding observations into rectified-flow dynamics while embedding hard physics via a constraint-preserving projection (e.g., incompressibility or conservation). Theoretically, we establish invariance guarantees to ensure that trajectories remain on the physics-consistent manifold throughout sampling. Experiments on various PDE systems demonstrate competitive reconstruction accuracy with sound physics consistency, while enabling efficient conditional sampling (e.g., 50 steps) and up to 320x faster inference than 2000-step guided diffusion baselines.
Hao Zhou, Rui Zhang, Han Wan +1
Sep 15, 2026cs.CV

Efficient 3D Whole-Body PET Image Denoising via Conditional Rectified Flow With Optimized Sampling Strategy

Reducing radiation exposure in Positron Emission Tomography (PET) is important for patient safety; however, ultra-low-dose imaging suffers from severe noise, which may affect diagnostic interpretation without appropriate image enhancement. While current 3D deep generative models, particularly diffusion models, have shown strong reconstruction fidelity, their practical use can be limited by long inference times. In contrast, faster 2D-based alternatives may have difficulty maintaining volumetric consistency, an important consideration for whole-body PET imaging analysis. To bridge this gap, we propose a one-pass conditional 3D rectified flow (3D Flow) framework for whole-body PET image denoising that incorporates a novel optimized non-uniform sampling strategy. The model is trained with a one-pass linear-interpolant velocity-matching objective. This approach reconstructs a full 3D volume in approximately 30 seconds in our implementation, compared with multi-hour inference for the evaluated 3D DDPM baseline. Evaluations including zero-shot transfer to an independent clinical dataset show that our model achieves favorable global image quality and lesion conspicuity compared with the evaluated 3D DDPM and DDIM baselines, including on challenging short-acquisition data. Furthermore, the proposed method shows promising zero-shot transfer performance across the evaluated datasets and unseen dose levels (down to 1/100 of the standard dose), with artifact-focused visual comparisons supporting the need for further lesion-level validation. By balancing reconstruction fidelity and computational efficiency, this work presents a candidate approach for ultra-low-dose whole-body PET image denoising.
Jiale Shen, Guolin Wang, Chenhao Wang +3
Feb 27, 2026eess.IV

Efficient Flow Matching for Sparse-View CT Reconstruction

Generative models, particularly Diffusion Models (DM), have shown strong potential for Computed Tomography (CT) reconstruction serving as expressive priors for solving ill-posed inverse problems. However, diffusion-based reconstruction relies on Stochastic Differential Equations (SDEs) for forward diffusion and reverse denoising, where such stochasticity can interfere with repeated data consistency corrections in CT reconstruction. Since CT reconstruction is often time-critical in clinical and interventional scenarios, improving reconstruction efficiency is essential. In contrast, Flow Matching (FM) models sampling as a deterministic Ordinary Differential Equation (ODE), yielding smooth trajectories without stochastic noise injection. This deterministic formulation is naturally compatible with repeated data consistency operations. Furthermore, we observe that FM-predicted velocity fields exhibit strong correlations across adjacent steps. Motivated by this, we propose an FM-based CT reconstruction framework (FMCT) and an efficient variant (EFMCT) that reuses previously predicted velocity fields over consecutive steps to substantially reduce the number of Neural network Function Evaluations (NFEs), thereby improving inference efficiency. We provide theoretical analysis showing that the error introduced by velocity reuse is bounded when combined with data consistency operations. Extensive experiments demonstrate that FMCT/EFMCT achieve competitive reconstruction quality while significantly improving computational efficiency compared with diffusion-based methods. The codebase is open-sourced at https://github.com/EFMCT/EFMCT.
Jiayang Shi, Lincen Yang, Zhong Li +3