cs.CVJul 13, 2026

From Reconstruction to Interpretation: Zero-Setup Multi-Phase Segmentation of X-ray Tomography Data

Authors: Pradyumna ElavarthiArun J. BhattacharjeeHarrison LisabethAnca RalescuPetrus H. ZwartDilworth ParkinsonElizabeth G. Clark

Organizations: Department of Computer Science, University of Cincinnati. · Energy Geosciences Division, Lawrence Berkeley National Laboratory. · Center for Advanced Mathematics in Energy Research Applications, Lawrence Berkeley National Laboratory. · Advanced Light Source, Lawrence Berkeley National Laboratory.

Abstract

X-ray tomography enables nondestructive characterization of material microstructures, while advances in micro-CT imaging have accelerated volumetric data acquisition and reconstruction. However, rapid interpretation remains limited by image segmentation, which often requires manual thresholding, user prompting, or material-specific model training. We present a zero-setup framework for multi-phase segmentation of synchrotron X-ray tomography data that generates interpretable masks for previously unseen datasets without user input or retraining during deployment. The framework combines a material-agnostic mask preparation strategy with a pretrained semantic segmentation network. It represents commonly occurring structural regions as background, sample, bright, dark-gray, light-gray, and porosity masks. Unlike conventional deep learning pipelines that require dataset-specific annotations and retraining, the proposed framework can be applied directly to new scans and produce diagnostic-level segmentations within minutes of reconstruction. This enables rapid assessment of scan quality, sample morphology, porosity, and attenuation variations during ongoing beamline experiments. The generated masks can later be manually refined or used to fine-tune application-specific models when greater accuracy or material-specific labeling is required. Evaluation on held-out synchrotron micro-CT images and qualitative testing on additional datasets demonstrate consistent and physically meaningful segmentations across varying samples and imaging conditions. The framework also substantially outperforms conventional intensity-based thresholding. By connecting high-speed reconstruction with immediate interpretation, the approach supports near-real-time beamline feedback and scalable AI-assisted scientific imaging workflows.

Explore similar work

Sep 22, 2026cs.CV

FleXray: Universal Clinical X-ray Segmentation

X-ray is medicine's most widely used imaging modality, yet remains among its least quantitative. Unlike volumetric modalities like CT or MRI, X-ray collapses 3D anatomy into a 2D projection, causing structures to overlap and anatomical boundaries to be ambiguous, even to experts. As a result, labeling X-ray databases for training general-purpose segmentation systems is impractical, leaving morphometric and functional X-ray analysis confined to narrow anatomical regions and applications. To this end, we present FleXray, a generalist model for anatomical segmentation across the entire body in clinical X-rays. Instead of curating large, manually annotated X-ray datasets, we build a scalable, physics-based generative X-ray data engine. Using existing 3D whole-body CT segmentation datasets and generative image-editing models, we simulate fully-annotated 2D X-rays with diverse appearances, physiological properties, and imaging geometries. Trained on these simulations, FleXray accurately segments 60 anatomical structures across unseen research datasets and in-the-wild X-rays. We further show that FleXray makes X-rays directly amenable to quantitative analysis, enabling automated measurements for disease grading, robust navigation during X-ray-guided interventions, and data-efficient learning of pathological targets. We release the model, code, a full-body X-ray segmentation dataset, and a local, easy-to-use browser-based tool at https://flexray.csail.mit.edu .
Victor Ion Butoi, Vivek Gopalakrishnan, John V. Guttag +2
Aug 25, 2025cs.CV

InSituRes: A Physics-Informed Same-Grid Model for Enhanced Dynamic X-ray Micro-CT Reconstructions

X-ray micro-computed tomography (micro-CT) provides non-destructive three-dimensional (3D) imaging of porous material microstructures. In situ experiments, including mechanical loading and reactive transport, increasingly require dynamic four-dimensional (4D) imaging with volumes repeatedly acquired during experiments. However, rapid acquisition typically requires fewer projections, shorter exposures, or reduced fields of view, producing reconstructions with noise, blur, and artifacts that obscure pores, microcracks, and interfaces. To address this challenge, this study introduces InSituRes, a physics-informed same-grid volumetric enhancement framework for fast dynamic X-ray micro-CT imaging of temporally evolving materials. InSituRes maps fast-acquisition volumes to higher-quality long-acquisition reconstructions using paired scans of the same specimens. The model integrates 3D convolutional feature extraction with slice-wise transformer attention to capture local and broader in-plane context. A learnable forward degradation model approximates rapid acquisition effects, including spatial blurring, intensity scaling differences, and signal-dependent noise. During training, reconstructed volumes should match high-quality reference scans and reproduce observed fast acquisition data after propagation through the forward model, imposing a physics-guided consistency constraint. Experiments on unseen micro-CT datasets demonstrate improved reconstruction fidelity and enhanced visibility of fine microstructural features relative to conventional interpolation and learning-based enhancement approaches. The framework supports quantitative interpretation of fast 4D X-ray micro-CT scans of evolving materials.
Qinyi Tian, Andrea Bisciotti, Soniya Tiwari +2
Feb 23, 2026cs.CV

Segmenting Low-Contrast XCTs of Concrete: An Unsupervised Approach

X-Ray Computed Tomography (XCT) is a compelling tool in experimental mechanics, capable of non-destructively extracting information pertaining to the internal morphology of materials. For materials with random heterogeneous morphology such as concrete, such information is of particular relevance since it allows for studies of morphology-related behaviour and for predictive modelling. Nevertheless, XCT images require semantic segmentation for practical usage. Here, concrete poses a unique challenge due to the similar X-ray attenuation coefficients of aggregates and mortar, which result in low contrast between the two phases in the ensuing XCT images. As such, purely intensity-dependent semantic segmentation tools remain unfeasible. While vision transformers (ViTs) and convolutional neural networks (CNNs) are proven techniques for semantic segmentation in such challenging cases, they typically require labelled training data, which is often unavailable for concrete or resource-intensive to obtain, thereby limiting their relevance. To address this challenge, a self-annotation technique is presented here that leverages superpixel algorithms to identify perceptually similar local regions in an image and relates them to the global context by utilizing the receptive field of a CNN-based model. This enables the model to learn a global-local relationship in the images and facilitates the identification of semantically similar structures. When evaluated against manually annotated ground truth on out-of-distribution data, the proposed methodology consistently outperformed direct greyscale thresholding across all pertinent metrics, demonstrating improved discernibility between aggregates and mortar, and providing the most favourable balance of sensitivity and precision for aggregate-phase identification.
Kaustav Das, Gaston Rauchs, Jan Sykora +1