cs.CVJul 14, 2026

C-Norm: Cell-Distribution Normalization Enables Precision Recognition of Medical-Cell Image

Authors: Yang QianlLiu XianyDai DawChen JingShen XiaojFu KaiwTang MingZou Dongl

Organizations: Chongqing University Cancer Hospital, Chongqing, China · Chongqing University of Posts and Telecommunications, Chongqing, China · Shanghai First Maternity and Infant Hospital, Tongji University, Shanghai, China

Abstract

ThinPrep Cytologic Test (TCT) enables early cervical cancer screening, but manual reading is time-consuming and yields inconsistent diagnostic results among cytopathologists. Existing AI detection models perform poorly under real clinical conditions, primarily restricted by two key constraints: unbalanced spatial distribution of cell populations in TCT slides, and limited high-quality annotated cytology data relying on professional pathologist labeling. To address these limitations, we propose a Cell-Distribution Normalization (C-Norm) method. By decoupling abnormal and normal cells from the original TCT images and re-synthesizing them, this method ensures a uniform distribution of cell populations, thereby mitigating generalization degradation caused by distribution bias. Building upon this, we integrate the YOLOv12 framework with a DINOv3 module. This hybrid architecture leverages the advanced detection capability of YOLO models and the superior feature representations of DINOv3 to capture subtle morphological nuances essential for precise recognition of TCT images. Extensive experiments demonstrate that our proposed method achieves state-of-the-art performance, significantly outperforming mainstream detection algorithms. The complete implementation is available at: https://github.com/ddw2AIGROUP2CQUPT/Cell-Norm

Explore similar work

Jul 11, 2026cs.CV

Geometry-aware Gaussian Prior and Axial Attention for Cervical Cytology Image Classification

Accurate cervical cytology image classification is a key component of automated cervical cancer screening, where reliable recognition of normal, precancerous, and cancer-associated cellular patterns from Pap smear images can improve screening efficiency and diagnostic consistency. However, this task remains challenging because cervical cells exhibit complex morphology, subtle intra-class variations, and strong inter-class similarities. Existing convolution-based models capture local texture well but have limited ability to model long-range relationships, whereas attention-based models provide broader context but often lack explicit structural guidance. To address these limitations, we propose a geometry-aware classification framework for cervical cancer screening-oriented cytology image analysis, incorporating semantic abstraction and structural priors learned from pre-trained vision-language features. The method uses Gaussian expert modules to generate axis-wise priors from global semantic information, capturing structural regularities such as nuclear alignment and cellular spatial organization. These priors are embedded into an axial self-attention module to modulate similarity computation along horizontal and vertical directions, improving long-range dependency modeling and structure-sensitive feature interaction. Experiments on the Mendeley liquid-based cytology and SIPaKMeD datasets show that the proposed method achieves 99.48% accuracy on the former and 96.08% on the latter, with balanced gains in recall, precision, and overall classification performance. Visual analysis further shows that the learned priors highlight diagnostically relevant cellular regions, demonstrating the potential of the proposed framework as a screening-oriented decision-support tool for cervical cytology.
Yating Li, Cheng Ye, Nenan Lyu +2
Jul 28, 2026cs.CV

Group Equivariant Diffusion for Anomaly Detection in Computational Cytology

Computational cytology on whole-slide images is challenging because malignant cells are rare, heterogeneous, and annotated slides are scarce. Anomaly detection frameworks can be trained on normal slide-negative patches and then applied at test time to flag abnormal patches in held-out slides. Most unsupervised anomaly detection approaches including generative ones (GAN-based and diffusion-based), are tuned to organ-level imaging and require large curated datasets. In cytology the signal is cell-centric: rotating or flipping a single-cell patch does not change its diagnostic class, yet standard diffusion models treat transformed views as distinct inputs, leading to transformation-dependent reconstructions and unstable anomaly scores. We propose a D4-equivariant diffusion framework that enforces rotation and reflection symmetry both architecturally, via a D4-equivariant U-Net, and at inference, via equivariant noise coupling and (optionally) frame averaging. This alignment with biological invariance yields transformation-consistent pseudo-healthy reconstructions and more stable anomaly ranking under symmetry. On two publicly available cytology datasets of bone marrow and peripheral blood smears, our D4-equivariant diffusion models achieve higher AUC and retrieve more abnormal cells in the top K predictions than non-equivariant generative baselines, a deep one-class, and a multiple instance learning based method, while substantially reducing score variance across rotations and flips. Code is available at https://swchmida.github.io/D4diffCyto/.
Swarnadip Chatterjee, Ssharvien Kumar Sivakumar, Anirban Mukhopadhyay
May 17, 2026cs.CV

Systematic Evaluation of Vision Transformers for Automated Cervical Cancer Classification: Optimization, Statistical Validation, and Clinical Interpretability

Manual Pap smear analysis for cervical cancer screening is limited by inter-observer variability, time constraints, and restricted expert availability. Although convolutional neural networks (CNNs) have automated cervical cell classification, they remain limited in modeling long-range spatial dependencies and often lack clinical interpretability. In this study, Vision Transformer (ViT) architectures were systematically optimized to enhance automated cervical cancer screening, which resulted in improved interpretability. The Herlev dataset (917 images: 242 normal, 675 abnormal) was utilized to optimize ViT-Tiny, a lightweight Vision Transformer architecture designed for reduced computational complexity, through a comprehensive evaluation of augmentation strategies, class weighting, and hyperparameters. The optimal configuration achieved 94.9%-95.2% cross-validation accuracy, in which random horizontal flipping and class weighting (0.7 x 1.3) were identified as most effective. Gradient-weighted Class Activation Mapping (Grad-CAM) analysis confirmed that model attention corresponded to clinically relevant morphological features, which include nuclear regions, cell boundaries, and chromatin texture, which align with cytopathological criteria. These findings indicate that Vision Transformers can deliver accurate and interpretable decision support for cervical cancer screening, which fulfills both clinical performance and transparency requirements essential for medical AI deployment.
Nisreen Albzour, Sarah S. Lam