cs.AIJul 28, 2026

Cardiologent: Multi-Agent Clinical Decision Support for Patient-Level Arrhythmia Assessment, Urgency, and Management

Authors: Sukju OhMoo-Yong RheeJae-Sik JangSukkyu Sun

Abstract

The same episode of atrial fibrillation is a minor finding in a healthy adult and grounds for anticoagulation in an elderly patient with hypertension: identical signal, opposite decision. Naming the rhythm is only the start; what determines a patient's outcome is the judgement that follows -- what the arrhythmia is across the whole record, what it means for this patient, and what should be done about it. Recent work pairing large language models with the ECG stops short of this, reading one recording without assembling a patient-level finding; and agentic systems built around it either receive the arrhythmia a device has already detected or target a different diagnostic task, stopping before the decision this task requires. We formulate patient-level arrhythmia decision support as a task and present Cardiologent, a multi-agent system that spans it from detection to decision. An agent for each signal -- a single ECG lead and the photoplethysmogram a wearable acquires -- grounds its window reading in measured features rather than a bare label; the readings are assembled into the patient's rhythm profile and, with the patient's own data, reasoned against clinical guidelines retrieved for the case, with a critic checking each conclusion against the guideline it cites. We evaluate the clinical decision rather than the report, across integrated diagnosis, clinical significance, and urgency and management. Cardiologent scores highest on every axis, first on every patient-level task under both cardiologists and an at-scale LLM judge -- whose agreement with the cardiologists (ICC 0.74, 0.66) matches theirs with each other (0.67). Because each conclusion traces to a cited guideline and is validated against expert cardiologists, it yields decisions a clinician can audit rather than act on blindly -- a step toward use in continuous monitoring.

Explore similar work

May 15, 2026cs.LG

DeepArrhythmia: Segment-Contextualized ECG Arrhythmia Classification via Selective Evidence Acquisition

Beat-level Electrocardiography (ECG) arrhythmia detection aims to assign an arrhythmia class to each beat in a recording, yet many existing systems treat beats as isolated local instances. This is limiting because beat labels often depend on multi-beat rhythm context, including timing, compensatory pauses, and beat-to-beat morphological consistency. We present DeepArrhythmia, a tool-grounded multimodal framework for segment-contextualized beat-level ECG arrhythmia classification. Given a multi-beat ECG segment, DeepArrhythmia combines the raw ECG signal and a rendered waveform image, localizes R peaks to identify beat instances, and produces structured beat-level predictions. The framework decouples physiological measurement from evidence integration using specialized tools for beat localization, numerical rhythm--morphology extraction, and morphology-focused textual analysis. DeepArrhythmia uses segment-level confidence to route between minimal and rich evidence states, since richer physiological evidence is not uniformly useful. This agentic design integrates rhythm context, explicit physiological grounding, and selective evidence acquisition for decision making.
Jiahui Li, Ruili Fang, Zishuai Liu +3
Aug 10, 2026eess.SP

Diagnosing as Cardiologists Do: ECG Agents with Doctor-Grounded Priors for Clinical Reasoning Across Diseases and Populations

Cardiologists interpret electrocardiograms by localizing waveform components, measuring rhythm and interval patterns, and translating these structured observations into diagnostic evidence. Whether this expert reading process can serve as an effective prior for ECG agents remains unclear. To address this question, we introduce LuminaECG, a clinically structured ECG reasoning framework that reformulates ECG interpretation as measurement-grounded visual reading. ECG signals are rendered on standard electrocardiographic grid paper to preserve the spatial and scale cues used in clinical reading. P-wave, QRS-complex, and T-wave boundaries are explicitly delineated, and color-coded segmentation decomposes the waveform into discrete visual measurement primitives. A general 2B vision-language backbone is then trained with low-rank supervised fine-tuning to associate these primitives with diagnostic reasoning, without architectural modification. Across open, proprietary, and ECG-specialist zero-shot baselines, LuminaECG improves both waveform measurement and diagnostic recovery. It reaches a clinically meaningful reader tier on the CODE-test benchmark, transfers across geographically diverse ECG datasets without retraining, and generates reports whose structure contains an emergent prognostic signal. These findings suggest that effective ECG agents require not only larger models, but supervision that preserves the alignment between measurable waveform evidence and clinical knowledge.
Hongxiang Gao, He-yang Xu, Yuwen Li +6
May 25, 2026cs.AI

A Signal-Language Foundation Model for Broad-Spectrum Cardiovascular Assessment from Routine Electrocardiography

Electrocardiography (ECG) is central to cardiovascular care, but conventional AI models are often restricted to common arrhythmias and may generalize poorly across populations or clinically subtle diseases. We developed ECG Contrastive Language-Image Pre-training (ECGCLIP), a signal-language contrastive learning framework that aligns ECG waveforms with expert diagnostic reports. ECGCLIP was pre-trained on 2,837,962 ECG studies from 1,324,856 patients and evaluated on a held-out internal test set plus nine independent external cohorts comprising about 1.5 million ECGs. Evaluation covered 89 downstream tasks, including 45 ECG diagnoses, 39 echocardiographic targets, and 5 rare cardiac diseases, using PRAUC as the primary metric. ECGCLIP consistently improved performance over random initialization and Merl-R18 baselines. On the internal test set, ECGCLIP-R34 achieved strong performance for atrial fibrillation (PRAUC 0.900) and ST-segment elevation myocardial infarction (PRAUC 0.383), with robust generalization across all external cohorts. It also improved low-prevalence and diagnostically elusive diseases, including Ebstein anomaly, constrictive pericarditis, dextrocardia, and cardiac amyloidosis, with internal PRAUC values of 0.253, 0.175, 0.121, and 0.201, respectively. ECGCLIP was data efficient, matching or exceeding full-dataset baseline performance with only 10% of training data. Feature visualization and saliency analysis suggested clinically meaningful representations aligned with established electrocardiographic criteria. These findings indicate that large-scale ECG-report contrastive pre-training can expand routine ECG interpretation beyond common arrhythmias toward broad cardiovascular assessment and opportunistic screening of echocardiographic and rare conditions.
Ziqing Yu, Yuhui Tao, Jiayu Huo +19