cs.LGJul 28, 2026

DRIFT: Direct-Recursive Intervention-Conditioned Forecasting of ICU Physiological Trajectories

Authors: Weixin LiuJuming XiongCongning NiYanfan ZhuXingtao LinBradley A. MalinZhijun Yin

Abstract

Many time-series forecasts depend not only on prior observations but also on actions specified during the forecast period. In intensive care units (ICUs), future vital signs and laboratory values are influenced by treatments such as vasopressors. However, models that predict the full future sequence all at once make little use of these treatments, whereas autoregressive models can accumulate errors. We introduce DRIFT, a hybrid framework in which a direct model produces the primary forecast and a recursive, action-conditioned model contributes constrained corrections. We evaluate DRIFT on 6,046 admissions from MIMIC-IV and 8,345 admissions from eICU-CRD. Averaged across the 8-, 24-, and 48-hour forecast endpoints, DRIFT reduces mean absolute error for mean arterial pressure (MAP) by 0.673% relative to an action-conditioned Temporal Fusion Transformer (TFT-action) on MIMIC-IV and achieves the lowest corresponding error among the compared models on eICU-CRD. Although the overall accuracy improvement is modest, a MIMIC-IV audit restricted to windows in which the supplied treatment sequence was altered showed that DRIFT achieved lower observed-target MAP error than TFT-action at 8 and 24 hours. Treatment-sequence alteration increased DRIFT's MAP error by 0.21-0.26 mmHg more than it increased TFT-action's error, with prediction changes occurring primarily after the supplied paths diverged. In a separate robustness experiment, the MAP advantage persisted under three shared checkpoint-selection rules emphasizing overall endpoint error, MAP error, or both equally.

Explore similar work

Jul 21, 2026cs.LG

Biological Amnesia in ICU Time-Series Prediction: A Drift-Adaptive Two-Stream Architecture with Temporal Retrieval

Background: Clinical decision support systems degrade silently as treatment protocols evolve, yet standard adaptation methods treat models as monolithic blocks, unable to distinguish stable patient physiology from shifting institutional practice. Methods: We propose an adaptive clinical intelligence architecture for ICU intervention prediction that structurally decouples physiological from treatment representations, confining parameter updates to the treatment stream upon a dual distributional and accuracy trigger. Automated audit logs record which treatment features drove each adaptation event and how their importance shifted. At inference, an attribution-driven Temporal RAG module grounds each prediction in patient-specific, era-matched PubMed evidence anchored to the patient's dominant physiological features. Experiments used 84,792 MIMIC-IV stays (2008-2022) under strict chronological split. Results: Drift localised entirely to the treatment stream, validating the structural prior. Selective adaptation improved vasopressor and septic shock discrimination and calibration over the static source model. A fully retrained baseline yielded marginally higher aggregate discrimination but missed 26 septic shock cases the framework correctly identified, with none in the reverse direction; retrieval consistency with the pre-adaptation source model was preserved by the framework but degraded substantially in the retrained baseline. Conclusions: Structurally constraining adaptation to drifting components while preserving stable physiological representations enables clinical AI to evolve with practice without distorting learned patient biology. This architecture offers a template for governable, interpretable deployment of adaptive models in high-stakes clinical environments.
Fatema Ferdous Tamanna, K. M. Merajul Arefin, Md. Abdul Masud
Sep 8, 2026cs.LG

Physics-Informed Deep Learning for False Ventricular Tachycardia Alarm Reduction in the ICU

False ventricular tachycardia (VT) alarms are a leading contributor to alarm fatigue in intensive care units. We propose a deep learning framework combining a 1D SE-ResNet with ICU-realistic data augmentations and a physics-informed auxiliary reconstruction task based on the three-element Windkessel hemodynamic model, implemented as a differentiable forward simulation. By requiring the network's latent representation to produce physiologically plausible arterial pressure waveforms, artifact-driven ECG patterns are penalized while true VT remains coherent across modalities. Evaluated on the VTaC benchmark under a strict real-time protocol (10-second pre-alarm window), our method achieves a 5-point Challenge Score improvement over prior state-of-the-art. Ablation studies confirm that the physics-informed objective is the primary performance driver, providing gains in accuracy, 2x label efficiency, and more localized and clinically meaningful ECG segments.
Athanasios Papastathopoulos-Katsaros, Alexandra Stavrianidi, Zhandong Liu
Aug 30, 2026cs.LG

INTERVenE: Temporal-Abstraction-Interval Based Transformers for Short-Horizon Medical Event Prediction

Electronic Health Record (EHR) prediction models in the intensive care unit must learn from sparse and irregular measurements while preserving the clinical meaning of time and supporting transparent decision-making. We present INTERVenE, a family of Transformer architectures whose input is an interval-based, knowledge-based temporal abstraction (KBTA), a token stream of named clinical concepts (states, trends, events, contexts) drawn from a curated medical ontology, rather than an unnamed bin index or a raw measurement triplet. This naming layer is what we ask KBTA to do: it makes the model's per-token attributions resolve to clinical concepts by construction. INTERVenE offers two complementary variants: an auto-regressive decoder that generates future abstraction trajectories with a per-step risk readout (localizing \emph{when} and \emph{after which events} risk rises), and a bidirectional encoder for single-pass joint risk and time-to-event prediction. Evaluated on 57,078 MIMIC-IV admissions against GRU-D, STraTS, and KarmaLego, INTERVenE-Enc reaches a support-weighted AUPRCw_w of 0.672, improving by 0.041 over the strongest neural baseline with non-overlapping 95% bootstrap CIs, while also taking the best AUROCw_w (0.901) and length-of-stay MAE (44.4,h). INTERVenE-Ar (AUROCw_w 0.8540.854, AUPRCw_w 0.5870.587 under the same evaluation contract - a strictly harder generative readout) provides a complementary token-level risk trajectory. An input-representation ablation confirms the lift transfers across structured discretizations, positioning KBTA-based intervals as the interpretable substrate that makes per-token attributions resolve to meaningful clinical concepts within the deployed model.
Shahar Oded, Yuval Shahar