eess.IVAug 5, 2026

A Foundational EDM2-Based Generative Model for High-Resolution Synthetic Fetal Ultrasound Imaging from Open Datasets

Authors: Harvey ManneringYilin ZhangZiao LiuZhiwu HuangJacqueline MatthewMiguel Xochicale

Abstract

Prenatal ultrasound imaging is key for assessing fetal health, but AI progress is limited by scarce, privacy-restricted, and hard-to-annotate datasets. We propose a high-resolution fetal ultrasound synthesis framework based on the EDM2 diffusion architecture, trained on multiple public datasets to generate 512x512 images across six anatomical classes. Our method achieved improved image quality with lower FID scores and enhanced downstream fetal plane classification, reaching 93.36% ensemble accuracy after fine-tuning, surpassing real-data-only training. Clinical evaluation by an experienced fetal ultrasound specialist (10+ years) on 100 images yielded a mean realism score of 2.67/5, with real images rated higher than synthetic. Artefacts included smoothing, speckle irregularities, and anatomical inconsistencies. Code, data, models and other resources to reproduce this work are available at https://github.com/xfetus/fetal-ultrasound-edm2.

Explore similar work

May 27, 2026eess.IV

Benchmarking Ultrasound Foundation Models for Fetal Plane Classification

Ultrasound is widely used in obstetric care due to its safety, accessibility, and real-time imaging. However, interpretation remains operator-dependent and susceptible to noise and artifacts. Deep learning models have shown strong performance to solve these problem, but they typically require large annotated datasets that are difficult to obtain in clinical ultrasound. Foundation models (FMs) offer an alternative, using a large number of ultrasound images to learn transferable representations that can generalize with limited labeled data. This work presents a comprehensive benchmark of ultrasound-specific FMs for fetal plane classification. We evaluated four ultrasound FMs (USFM, MOFO, UltraSAM, FetalCLIP) against two CNN baselines (ResNet50, EfficientNet-V2) and a ViT (DINOv3) pretrained on natural images. We trained all models under two complementary settings: full fine-tuning and linear probing with a frozen encoder. All models were trained using 5-fold patient-level cross-validation on a Spanish fetal ultrasound dataset and tested on both in-domain data and an external African cohort to assess cross-population generalization. We found that FetalCLIP achieved the best results in the linear probing setting (F1 = 0.9261 for in-domain, F1 = 0.9731 for out-of-domain), while USFM performed best in the full fine-tuning setting (F1 = 0.9476 for in-domain, F1 = 0.9515 for out-of-domain). MOFO and UltraSAM degraded most in both settings, underperforming natural image pretrained models in some cases. These findings highlight how the choice of pretrained model strongly affects fetal plane classification performance, since different pretraining objectives lead to different levels of transferability.
Leya Barrientos, Yuexi Du, Nicha C. Dvornek
Jul 13, 2026cs.CV

Feature-Space Guided Diffusion for Realistic Ultrasound Image Synthesis

Conditional diffusion models can generate anatomically plausible medical ultrasound (US) images, but anatomical plausibility alone does not ensure realistic B-mode appearance. Most US pipelines adapt standard generative architectures and condition them on anatomical masks, or use guidance mechanisms that reinforce the same anatomical signal. However, B-mode US images are shaped by acquisition-dependent properties such as speckle texture, tissue contrast, and attenuation. Using a frozen US foundation model, we show that standard conditional diffusion baselines remain separated from real images in representation space. In this work, we propose Feature-Space Candidate Guidance (FSCG), a training-free sampling strategy to reduce this gap. At sampling time, FSCG applies local k-NN feature correction and selects the best of multiple stochastic candidates according to their feature-space energy. In this way, the mask defines the anatomy, while FSCG steers samples toward the real US domain. Across three different datasets, FSCG reduces average FID64 by 56%, FID192 by 57%, and nearest-neighbour feature distance by 47% over standard conditional diffusion sampling, outperforming alternative inference-time guidance baselines. The results suggest that domain-aware feature representations can reveal and reduce realism gaps in medical diffusion synthesis without retraining the generator. Our code is available at https://github.com/marinadominguez/FSCG.
Marina Domínguez, Nélida Mirabet-Herranz, Valery Naranjo
May 19, 2026cs.CV

Synergistic Foundation Models for Semi-Supervised Fetal Cardiac Ultrasound Analysis: SAM-Med2D Boundary Refinement and DINOv3 Semantic Enhancement

We present a semi-supervised framework for joint segmentation and classification of fetal cardiac ultrasound images. Built upon the EchoCare multi-task backbone, our method integrates SAM-Med2D for boundary refinement and leverages DINOv3 to enhance pseudo-label quality. We introduce view-specific hard masking along with a two-stage optimization strategy: an EMA phase to consolidate segmentation capabilities, followed by a Classification Fine-Tuning phase that freezes segmentation parameters and resets the classification head to recover classification performance without compromising segmentation gains. Evaluated on the FETUS 2026 leaderboard, our method achieves a Dice Similarity Coefficient at 79.99%, Normalized Surface Distance at 61.62%, and F1-score at 41.20%, validating the effectiveness of our approach for prenatal congenital heart disease screening. Source code is publicly available at: https://github.com/2826056177/zcst_fetus2026.
Tonghao Zhuang, Shanglong Hu, Yongsheng Luo +2