Zero-Shot Self-Supervised Learning (ZS-SSL) has emerged as a promising paradigm for accelerated Magnetic Resonance Imaging (MRI) reconstruction, eliminating the reliance on fully-sampled external datasets. However, learning solely from a single under-sampled scan suffers from supervision scarcity and optimization instability, often leading to overfitting or artifacts. To address these challenges, we propose a robust physics-driven ZS-SSL framework that synergizes physical consistency with image-domain non-local priors. Our method introduces three core innovations: (1) a Coil Sensitivity Map (CSM)-Guided Dynamic Repository, which stabilizes the training trajectory by filtering physically inconsistent artifacts based on coil sensitivity constraints; (2) a SPIRiT-based regularization, which enforces k-space self-consistency via a learned correlation kernel and stochastic masking; (3) a Non-Local Self-Similarity (NSS) Pixel Bank, which leverages the high-fidelity reference established by the former modules to explicitly mine non-local anatomical similarities, thereby augmenting supervision in the image domain. Extensive experiments on the FastMRI dataset demonstrate that our approach achieves state-of-the-art performance, particularly under high acceleration factors, effectively bridging the gap between zero-shot learning and supervised methods. The code is available at https://github.com/Zolento/NS-SSL.
Zero-shot MRI reconstruction relies on generative priors, but single-modality unconditional priors produce hallucinations under severe ill-posedness. In many clinical workflows, complementary MRI acquisitions (e.g. high-quality structural scans) are routinely available, yet existing reconstruction methods lack mechanisms to leverage this additional information. We propose MPFlow, a zero-shot multi-modal reconstruction framework built on rectified flow that incorporates auxiliary MRI modalities at inference time without retraining the generative prior to improve anatomical fidelity. Cross-modal guidance is enabled by our proposed self-supervised pretraining strategy, Patch-level Multi-modal MR Image Pretraining (PAMRI), which learns shared representations across modalities. Sampling is jointly guided by data consistency and cross-modal feature alignment using pre-trained PAMRI, systematically suppressing intrinsic and extrinsic hallucinations. Extensive experiments on HCP and BraTS show that MPFlow matches diffusion baselines on image quality using only 20% of sampling steps while reducing tumor hallucinations by more than 15% (segmentation dice score). This demonstrates that cross-modal guidance enables more reliable and efficient zero-shot MRI reconstruction.
Self-supervised deep learning-based methods have shown great promise for accelerated magnetic resonance imaging (MRI) reconstruction, achieving high image quality without requiring fully sampled data for training. These methods typically partition the acquired data into two disjoint subsets to construct input-target pairs for optimizing the reconstruction network. However, existing approaches perform this partition exclusively within the spatial frequency (k-space) domain, leaving the coil dimension unexplored. To enforce full exploitation of signal correlation across receiver coils, we propose CoilDrop-MRI, which applies coil-wise dropout to the input and uses the dropped data as training targets in a self-supervised framework. This method is integrated into unrolled architectures in both image-domain (SENSE) and k-space (SPIRiT) formulations. We further demonstrate its versatility by extending CoilDrop-MRI to multi-shot, phase-corrected diffusion MRI (dMRI) reconstruction. CoilDrop-MRI is extensively validated on multi-site, multi-field-strength (0.3T, 0.55T, and 3T), and multi-modality (T1-weighted, T2-weighted, T2-FLAIR, and dMRI) datasets and consistently outperforms state-of-the-art self-supervised methods, achieving quality comparable to supervised reconstruction methods without requiring fully sampled reference training data. Moreover, CoilDrop-MRI exhibits strong data efficiency and robust generalization across imaging conditions, establishing it as a practical and versatile framework for self-supervised parallel MRI reconstruction.
MRI reconstruction is an inherently ill-posed inverse problem, since incomplete measurements admit many plausible solutions. This ambiguity becomes more severe under high acceleration, where pixel-domain continuous predictors tend to average over feasible reconstructions and suppress high-frequency anatomy. We address this limitation by moving reconstruction to discrete multi-scale latent space and posing it as autoregressive next-acceleration-scale prediction. Leveraging discrete priors proven effective in visual autoregressive modeling, our method restricts the solution to compact sequences of codebook tokens, enabling sharp reconstructions even from extremely sparse measurements. This discrete autoregressive formulation also aligns naturally with modern large language model post-training techniques. Building on this observation, we introduce on-policy privileged information distillation for visual autoregressive modeling, where a teacher is provided training only privileged context that is unavailable at inference, in our case fully sampled acquisitions, and supervises a student trained on its own rollouts, leading to consistent reconstruction gains. Through extensive experiments on the fastMRI benchmark, we show that our approach delivers improved reconstruction performance across diverse sampling patterns under extreme undersampling. Project website is \href{https://yilmazkorkmaz1.github.io/discrete-mri-reconstruction-opd/}{here}.