High-resolution images of unprocessed surgical breast tissue can be obtained using microscopy with ultraviolet surface excitation (MUSE). This technique is considered a promising method for checking surgical margins during breast cancer surgery. In this study, MUSE images at 4x and 10x magnifications were compared using patch-level classification methods. Texture analysis (TA) based on local binary patterns (LBP) and deep learning (DL) with a base Vision Transformer (ViT) model were used. Both methods achieved similar performance at both magnifications. Using DL method, both 4x and 10x magnifications achieved 96.30% sensitivity, 100% specificity and 98.18% accuracy. Using TA method, 4x achieved better specificity (100% vs 93.33%) and 10x yielded higher sensitivity (100% vs 93.33%), but both had the same accuracy (96.67%). No clear improvement in performance was observed with 10x magnification. These results show that 4x imaging achieves the same diagnostic accuracy as 10x imaging. At the same time, 4x offers a larger field of view and faster image capture. Therefore, lower magnification can be effectively used in MUSE systems for accurate and efficient intraoperative margin assessment.
Breast cancer diagnosis demands rapid and precise tools, yet traditional histopathological methods often fall short in intra-operative settings. Deep Ultraviolet (DUV) fluorescence imaging emerges as a transformative approach, offering high-contrast, label-free visualization of whole-slide images (WSIs) with unprecedented detail, surpassing conventional hematoxylin and eosin (H&E) staining in speed and resolution. However, existing deep learning methods for breast cancer classification, predominantly patch-based, fragment spatial context and incur significant preprocessing overhead, limiting their clinical utility. Moreover, standard attention mechanisms, such as Spatial, Squeeze-and-Excitation, Global Context and Guided Context Gating, fail to fully exploit the rich, multi-scale regional relationships inherent in DUV-WSI data, often prioritizing generic feature recalibration over diagnostic specificity. This study introduces a novel Region-Affinity Attention mechanism tailored for DUV-WSI breast cancer classification, processing entire slides without patching to preserve spatial integrity. By modeling local neighbor distances and constructing a full affinity matrix, our method dynamically highlights diagnostically relevant regions, augmented by a contrastive loss to enhance feature discriminability. Evaluated on a dataset of 136 DUV-WSI samples, our approach achieves an accuracy of 92.67 +/- 0.73% and an AUC of 95.97%, outperforming existing attention methods.
Nagur Shareef Shaik, Teja Krishna Cherukuri, Dong Hye Ye
Vision Transformers (ViT) have become the architecture of choice for many computer vision tasks, yet their performance in computer-aided diagnostics remains limited. Focusing on breast cancer detection from mammograms, we identify two main causes for this shortfall. First, medical images are high-resolution with small abnormalities, leading to an excessive number of tokens and making it difficult for the softmax-based attention to localize and attend to relevant regions. Second, medical image classification is inherently fine-grained, with low inter-class and high intra-class variability, where standard cross-entropy training is insufficient. To overcome these challenges, we propose a framework with three key components: (1) Region of interest (RoI) based token reduction using an object detection model to guide attention; (2) contrastive learning between selected RoI to enhance fine-grained discrimination through hard-negative based training; and (3) a DINOv2 pretrained ViT that captures localization-aware, fine-grained features instead of global CLIP representations. Experiments on public mammography datasets demonstrate that our method achieves superior performance over existing baselines, establishing its effectiveness and potential clinical utility for large-scale breast cancer screening. Our code is available for reproducibility here: https://aih-iitd.github.io/publications/attend-what-matters
We present Aegis, a joint-embedding predictive architecture for breast cancer detection and density assessment in mammography. We train three Vision Transformer variants (Small/Base/Large) using self-supervised joint-embedding predictive architecture (JEPA) pre-training on 71,103 studies from 14 clinical sites, followed by supervised fine-tuning with progressive resolution scaling up to 2048x1536. On a curated 785-study test set, our largest model achieves area under the receiver operating characteristic curve (AUC) 0.949 for breast cancer triage with 93% sensitivity and 75% specificity at the optimal operating point. An ensemble combining our model with a U.S. Food and Drug Administration-cleared baseline further improves discrimination to 0.952 AUC. For breast density classification, the model achieves 0.953 AUC for binary (dense vs. non-dense) classification and 62.6% exact accuracy across four Breast Imaging Reporting and Data System (BI-RADS) categories, with 98.8% adjacent accuracy comparable to reported human inter-reader agreement. External validation on the public VinDr-Mammo dataset provides evidence of cross-population transfer under a different reference standard, with the largest model achieving 0.871 AUC for triage in a zero-shot setting.
Scott Chase Waggener, Sai Karthik Navuluru, Lakshman Tamil