cs.AIAug 12, 2026

Auditable agentic AI for evidence-grounded thyroid ultrasound diagnosis and reporting

Authors: Haifan GongShiyu ChenBodong WangYuqi WangShijie WangGuoliang YouXinyu XiongHaowei Wang+6 more

Abstract

Thyroid ultrasound diagnosis requires coordinated lesion localization, measurement, risk stratification and reporting, yet most AI systems address these tasks in isolation and provide limited support for clinical review. We present ThyroidXAgent, a clinician-interactive agentic AI system that coordinates specialized diagnostic tools and stores their outputs as an auditable case-level evidence record. The system was developed using OpenThyroidDB, a multicentre, multitask resource integrating approximately 0.3 million ultrasound images and 24,000 paired reports, and was evaluated on 28,458 non-overlapping test cases, including 8,721 cases from 35 centres in the private NHC-MISD-TUS cohort. Across heterogeneous datasets, ThyroidXAgent achieved a mean Dice score of 87.21 percent for nodule segmentation and a mean AUROC of 0.9466 for benign-malignant classification. The same workflow supported lymph-node metastasis prediction and follicular versus papillary thyroid carcinoma classification, with AUROCs of 0.864 and 0.805, respectively. For report generation, evidence-grounded assembly outperformed multimodal language-model baselines across three cohorts. ThyClinScore, a lesion-level clinical semantic metric introduced here, showed the strongest correlation with a location-aware language-model judge. ThyroidXAgent improved physician classification accuracy, increased report diagnostic consistency from 70.3 percent to 86.2 percent, and reduced segmentation and reporting time by 35.9 percent and 27.4 percent, respectively. These findings support auditable, clinician-correctable agentic AI for thyroid ultrasound diagnosis and reporting.

Explore similar work

Jul 13, 2026eess.IV

Calibrated Selective Prediction Using Deep Ensembles for ROI-Based Thyroid Nodule Ultrasound Classification Under Dataset Shift: A Retrospective Evaluation

Background: Deep learning models can classify thyroid nodules on ultrasound, but reliable clinical decision support also requires calibrated probabilities, uncertainty estimation, and selective referral, particularly under dataset shift. Methods: We developed a calibrated deterministic five-member deep ensemble for ROI-based thyroid nodule classification and selective image-based triage. TN5000 was used for model development, five-fold cross-validation, member-wise vector-scaling calibration, and fold-specific threshold selection. TN3K served as an independent external dataset-shift evaluation. The framework used ConvNeXt-Tiny with squeeze-and-excitation attention, ensemble-mean malignancy probability, and mutual information (MI) as an ensemble-disagreement score. A three-tier policy assigned images to No-FNA suggestion, FNA recommendation, or radiologist review. Results: On pooled out-of-fold TN5000 predictions, the ensemble achieved AUC-ROC 0.9395, AP 0.9715, ECE 0.0088, and Brier score 0.0813. At 50% nominal MI retention, 7.2% of cases received a No-FNA suggestion, 39.9% an FNA recommendation, and 52.9% radiologist review, with 98.3% No-FNA NPV and 99.83% malignancy capture. On TN3K, AUC-ROC decreased to 0.7870, AP to 0.7254, ECE increased to 0.1899, and Brier score to 0.2281. The frozen TN5000 policy assigned 83.7% to review, 1.0% to No-FNA, and 15.3% to FNA recommendation. No malignant image entered the No-FNA pathway, but FNA-recommendation PPV fell to 76.6%. Conclusion: The framework showed strong internal discrimination and calibration, but limited external threshold transportability. Selective prediction may help identify images unsuitable for automated triage, but local recalibration, threshold validation, and prospective clinical evaluation are required before deployment.
Md. Sadibul Hasan Sadib, Md. Mohayminul Mukit, Rahmatul Kabir Rasel Sarker +2
Apr 30, 2026cs.CV

Echo-α: Large Agentic Multimodal Reasoning Model for Ultrasound Interpretation

Ultrasound interpretation requires both precise lesion localization and holistic clinical reasoning, yet existing methods typically excel at only one of these capabilities: specialized detectors offer strong localization but limited reasoning, whereas multimodal large language models (MLLMs) provide flexible reasoning but weak grounding in specialized medical domains. We present Echo-α, an agentic multimodal reasoning model for ultrasound interpretation that unifies these strengths within an invoke-and-reason framework. Echo-α is trained to coordinate organ-specific detector outputs, integrate them with global visual context, and convert the resulting evidence into grounded diagnostic decisions beyond detector-only inference. This behavior is established through a nine-task supervised curriculum and then refined by sequential reinforcement learning under different reward trade-offs, yielding Echo-α-Grounding for lesion anchoring and Echo-α-Diagnosis for final diagnosis. On multi-center renal and breast ultrasound benchmarks, Echo-α outperforms competitive baselines on both grounding and diagnosis. In particular, on cross-center test sets, Echo-α-Grounding attains 56.73%/43.78% F1@0.5 and Echo- α-Diagnosis reaches 74.90%/49.20% overall accuracy on renal/breast ultrasound. These results suggest that agentic multimodal reasoning can turn specialized detectors into verifiable clinical evidence, offering a practical route toward ultrasound AI systems that are more accurate, interpretable, and transferable. The repository is at https://github.com/MiliLab/Echo-Alpha.
Jing Zhang, Wentao Jiang, Tao Huang +8
Jun 17, 2026cs.HC

A Clinician-Centered Pipeline for Annotation and Evaluation in Ultrasound AI Studies

Clinician-centered evaluation is critical for validating medical AI systems, especially in ultrasound imaging where quantitative metrics do not always capture clinical usability. Existing medical image platforms primarily focus on dataset labeling. They lack integrated support for blinded model comparison and reproducible evaluation workflows. We present a clinician-centered pipeline for remote annotation and evaluation in ultrasound AI studies. The proposed pipeline uses a centralized server and lightweight browser interfaces to enable clinicians to perform annotation, blinded ranking, and review without local dataset downloads. The pipeline also supports multi-rater participation, centralized result aggregation, and automated statistical analysis. We validate the pipeline in a fetal ultrasound segmentation study with six raters spanning expert, generalist, and non-expert experience levels. The system automatically generated Spearman correlation, Kendall's ττ, and top-1 selection statistics. Results indicated moderate to strong agreement across experts and other groups. The blinded evaluation results showed a tendency for later active learning models to be preferred. These outcomes suggest that the pipeline can support clinician-centered annotation and reproducible human-\ac{AI} evaluation studies in ultrasound imaging. The proposed pipeline is available on \href{https://github.com/13204942/SonoRate}{GitHub}.
Fangyijie Wang, Jianjun Yu, Wentao Shi +4