MISTac: A Vision-Based Tactile Sensor for Minimally Invasive Surgery

Authors: Robin Koch, Annabella Mascot, Rayan Younis, Martin Wagner, Stefanie Speidel, Mark Cutkosky, Ingo Sieber, Roberto Calandra

Organizations: LASR Lab, TUD Dresden University of Technology, Germany

Abstract

Minimally invasive and robot-assisted surgery offer many advantages over traditional open surgery, but deprive surgeons of tactile feedback and the ability to palpate tissue with their fingers. To address this lack of tactile feedback, we introduce the MISTac, a high resolution vision-based tactile sensor specifically designed for palpation in MIS. The sensor has a replaceable sensor tip with a diameter of 8 mm which allows it to fit through the trocars used in minimally invasive surgery. Its modular 3D-printed case design allows the use of bulky off-the-shelf illumination and imaging hardware that can easily be exchanged and upgraded. The sensor has an optical resolution of 176.68 μmμm, a tactile resolution of 250 μmμm, and can resolve forces as little as 24.3 mN. An in vivo study with the sensor shows its usability in minimally invasive surgery. We trained a machine learning model with the tactile data collected in the trial on a tissue classification task achieving an aggregate accuracy of ~84% in a leave-one-out cross validation. Tactile sensors have the potential to one day aid surgeons during minimally invasive surgery with tasks such as tissue classification or intra-operative tumor localization; MISTac is a small step towards this vision. We open-source MISTac at https://github.com/lasr-lab/mistac

Figures & tables

Explore similar work

Jul 21, 2026cs.RO

MVP-Tac: A Miniaturized Dual-Modal Vision and Photoelastic Tactile Sensor for Robot-Assisted Minimally Invasive Surgery

Robot-assisted minimally invasive surgery (RMIS) offers major benefits over open and conventional laparoscopic procedures, yet it still lacks tactile feedback for palpation while operating under strict requirements to preserve reliable vision for navigation and safety. In practice, visual feedback is indispensable, and tactile solutions that cannot coexist with vision are difficult to translate into RMIS tools. To address both needs, we introduce MVP-Tac, a compact, vision-based tactile sensor that provides co-located vision and tactile sensing. MVP-Tac uses reflective photoelastic imaging: a thin photoelastic elastomer produces stress-dependent interferograms under contact that are captured by an embedded camera through a miniaturized reflective polariscope. A semi-transparent membrane and controllable illumination enable switching between visual mode and tactile mode, enabling tactile perception without sacrificing vision. We validate MVP-Tac through force calibration in the 0 to 2 N range and demonstrate its potential for tumor palpation via video-based hardness classification on tissue phantoms, achieving 97% accuracy for exposed-tumor classification and 92% accuracy for subdermal-tumor classification. Finally, we conduct a simulated colonoscopy to validate both visual and tactile modalities in a constrained lumen, including vision-guided 3D photomapping of the luminal wall and in situ hardness classification of localized nodules. Overall, MVP-Tac provides a practical path toward restoring clinically useful palpation in RMIS while maintaining essential visual feedback. The design, fabrication, and firmware of MVP-Tac are open-sourced at https://mvp-tac.github.io/
Jun 24, 2026cs.RO

TacVerse: A Multi-Sensor Dataset and Benchmark for Cross-Sensor Vision-Based Tactile Perception

Vision-based tactile sensors (VBTSs) enable robots to infer contact geometry and force-related cues by imaging deformation through an internal camera, yet generalisation across sensor designs remains poorly understood. We present TacVerse, a multi-sensor dataset and benchmark for cross-sensor vision-based tactile perception. The dataset contains 106,800 tactile images from seven VBTSs and supports three downstream tasks: shape classification, grating classification, and force regression. Experiments are conducted under three settings: within-sensor training, zero-shot cross-sensor transfer, and few-shot adaptation. Strong within-sensor performance across all tasks indicates that the collected tactile observations are informative for the target objectives. Direct cross-sensor transfer, however, leads to substantial degradation. Shape classification is comparatively robust, whereas grating classification and force regression are more sensitive to sensor shift. Few-shot adaptation for force regression consistently improves performance on unseen target sensors but does not fully close the gap to within-sensor upper bounds. A representation study further shows that MAE (Masked Autoencoder) pretraining provides the most consistent gains across tasks and sensors. TacVerse provides a controlled testbed for studying sensor shift, data-efficient adaptation, and self-supervised learning in tactile perception.
Oct 7, 2026cs.RO

Hall Effect-Based Tactile Force Detection Sensor for Robot-Assisted Minimally Invasive Surgery

Robotic minimally invasive surgery has revolutionized surgical practice. However, as the surgeons are mechanically separated from the surgical tools, loss of tactile feedback occurs. We present a compact force sensor with three, millimeter scale sensing elements (taxels) that can be affixed to the grasping face of a robotic surgical tool. The sensor features a miniaturized design using Hall effect sensors and magnets embedded in a deformable elastomer contact layer. Sensor calibration is achieved with a 6 degree of freedom (DoF) parallel robot. Each taxel can detect applied normal and shear forces with average RMSE of 2.133 kPa. The calibrated sensor was validated on phantom and ex vivo porcine tissue, demonstrating tactile sensing during retraction as well as slip. This work introduces a small-scale Hall effect based tactile sensor, enabling sensing for force-sensitive robotic surgical applications.