cs.CVAug 14, 2026

Zero-Shot Adaptation of Medical Vision Foundation Models for High-Frequency Micro-Ultrasound Prostate Segmentation

Authors: Ayusha Abbas, Saram Abbas, Kabita Adhikari

Organizations: Newcastle University Newcastle Upon Tyne, UK

Abstract

Prostate cancer claims a life every 80 seconds. Early detection is needed to prevent disease progression, and both PSA density calculation and biopsy decisions rely on knowing the exact boundary of the gland. Conventional ultrasound at 6-12 MHz blurs this boundary, missing one in three high-risk cancers. Micro-ultrasound (29 MHz) improves resolution threefold but introduces dense acoustic speckle that obscures the outer wall; given the same image, two clinicians draw outlines differing by over 10% in area. Supervised methods are costly and generalise poorly across scanners. Can a foundation model segment the prostate with no training data? We present the first zero-shot pipeline for this modality: MedSAM, pre-trained on over 1.5 million medical images, localises the prostate; we then apply CLAHE to sharpen the outer wall, binary dilation to recover missed pixels, and Fourier smoothing (4 modes, s=1.05) to refine the boundary. MedSAM requires a spatial prompt, so we evaluate bounding-box and point-click strategies across 75 patients of the Micro-Ultrasound Prostate Segmentation dataset (2,621 slices). On the 20-patient held-out test set, the pipeline reduces mean boundary-distance error by 45% (Dice 0.749+/-0.043 to 0.865+/-0.029; HD95 217.2+/-36.9 to 120.1+/-26.1 px), reaching Dice 0.859 across the cohort. Its mean overlap shows no significant difference from the three non-expert rater groups (p>0.19), while segmenting 38-52% more consistently (lower inter-patient standard deviation). Point-click prompts fail regardless of placement (best Dice=0.350), because speckle gives no stable local contrast. Only an approximate bounding box is required, so any clinic can deploy it without data collection, annotation, or retraining.

Figures & tables

Explore similar work

Jun 29, 2026

Learning Where to Look: A Reinforcement Learning Framework for Robust Micro-Ultrasound Prostate Cancer Detection

Micro-ultrasound (μμUS) is a new, emerging, and promising imaging modality for prostate cancer (PCa) detection, but accurate identification of suspicious tissue remains highly dependent on clinical experience, leading to substantial inter-observer variability. Machine-learning assistance can reduce this variability; however, training reliable deep models is challenging because supervision is sparse and noisy -- typically limited to core-level histopathology outcomes (e.g., cancer grade and its percentage in a biopsy core) without pixel-level lesion annotations and under severe class imbalance. We introduce Prost-RL, which reframes μμUS PCa detection as a spatially aware, policy-driven inference problem by learning where to look before decoding. Prost-RL integrates a lightweight reinforcement-learning policy into a foundation-model encoder-decoder to generate interpretable spatial attention maps that act as soft prompts for both cancer-likelihood heatmap prediction and image-level classification. We further propose Adaptive Policy Optimization (APO) to stabilize hybrid supervised-RL training and a noise-robust objective combining symmetric cross-entropy with negative-entropy regularization to mitigate weak-label noise and encourage sharp localization. On a cohort of 6,607 biopsy cores from 693 patients across five clinical sites, Prost-RL achieves 79.0±3.579.0\pm3.5 AUROC with 64.6±6.364.6\pm6.3% sensitivity at 80% specificity for core-level detection (+2.1 AUROC and +4.5 sensitivity points over the strongest baseline), and 79.3±5.879.3\pm5.8 AUROC for clinically significant cancer classification. The learned policy highlights biopsy-aligned regions, providing transparent, spatially grounded evidence alongside quantitative risk predictions. Code is available at: https://github.com/DeepRCL/Prost-RL.
Mar 4, 2026

ProFound: A moderate-sized vision foundation model for multi-task prostate imaging

Many diagnostic and therapeutic clinical tasks for prostate cancer increasingly rely on multi-parametric MRI. Automating these tasks is challenging because they necessitate expert interpretations, which are difficult to scale to capitalise on modern deep learning. Although modern automated systems achieve expert-level performance in isolated tasks, their general clinical utility remains limited by the requirement of large task-specific labelled datasets. In this paper, we present ProFound, a domain-specialised vision foundation model for volumetric prostate mpMRI. ProFound is pre-trained using several variants of self-supervised approaches on a diverse, multi-institutional collection of 5,000 patients, with a total of over 22,000 unique 3D MRI volumes (over 1,800,000 2D image slices). We conducted a systematic evaluation of ProFound across a broad spectrum of 1111 downstream clinical tasks on over 3,000 independent patients, including prostate cancer detection, Gleason grading, lesion localisation, gland volume estimation, zonal and surrounding structure segmentation. Experimental results demonstrate that finetuned ProFound consistently outperforms or remains competitive with state-of-the-art specialised models and existing medical vision foundation models trained/finetuned on the same data.
Jul 31, 2026

UltraSAM3: A Concept-Driven Foundation Model for Universal Ultrasound Image Segmentation

Ultrasound imaging has become increasingly widespread in clinical practice due to its portability, low cost and real-time capability, making ultrasound image segmentation important. However, ultrasound images differ substantially from CT, MRI, and other medical imaging modalities, as they are often affected by speckle noise, low contrast, acoustic shadows and ambiguous boundaries. Existing ultrasound segmentation methods are still mainly limited to task-specific models or visual-prompt-based foundation models, which are either tailored to particular tasks or require expert-provided visual prompts, making them inconvenient for flexible clinical use. To address these challenges, we propose UltraSAM3, a concept-driven foundation model for universal ultrasound image segmentation. Unlike conventional models, UltraSAM3 enables text-based target specification by adapting SAM3 to ultrasound-specific image--mask--concept triplets. The model is trained on a large-scale ultrasound segmentation corpus covering 37 public datasets and 13 anatomical categories, allowing it to align ultrasound visual patterns with clinically meaningful concepts across diverse organs and lesions. To further improve usability under realistic clinical interaction, we propose an instruction-guided agent that parses complex natural language queries into concise ultrasound concept prompts for UltraSAM3. Extensive experiments demonstrate that UltraSAM3 consistently outperforms representative concept- and text-driven biomedical segmentation models on multi-organ ultrasound benchmarks, external datasets, and visual-prompt-enhanced settings. Moreover, the agent improves segmentation robustness for complex user instructions. These results indicate that ultrasound-specific concept adaptation is effective for building generalizable and interactive ultrasound segmentation foundation models.