cs.CVAug 17, 2026

The Right Prior for the Right Deformation: Rethinking Continuous Deformable Image Registration

Authors: Hengjie Liu, Chushu Shen, Dan Ruan, Ke Sheng

Organizations: Department of Radiation Oncology, University of California, San Francisco, San Francisco, CA, USA · Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA · Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, USA · Department of Radiation Oncology, University of California, Los Angeles, Los Angeles, CA, USA

Abstract

Deformable image registration models implicitly encode deformation priors through their parametrization and optimization. In this work, we conduct a validation study on continuous registration methods to examine how these implicit priors affect performance across different registration tasks. Classic B-Spline transformations impose locality, smoothness, and scale through their control-point structure, whereas recent INR-based methods impose different priors through neural parameterization and optimization. We compare INR-Dense (IDIR), which directly models a dense displacement field using a SIREN-based INR; INR-BSCP (SINR), which predicts B-Spline control points with an INR; D-BSCP, which directly optimizes single-scale B-Spline control points; and MR-D-BSCP, which adds a multiresolution coarse-to-fine scheme. Experiments on inter-subject brain MR registration (OASIS) and intra-subject exhale-to-inhale lung CT registration (DIR-LAB 4DCT) reveal different behavior across deformation regimes. On OASIS, where deformations are moderate but locally complex, D-BSCP matches or slightly outperforms INR-BSCP, suggesting that the B-Spline parameterization accounts for much of INR-BSCP's effectiveness. On DIR-LAB 4DCT, where respiratory motion is larger and more coherent, single-scale B-Spline methods (D-BSCP and INR-BSCP) are less suitable, while INR-Dense and MR-D-BSCP are more effective. Across both tasks, MR-D-BSCP achieves the best performance among the tested continuous parameterizations. These findings highlight that registration accuracy depends strongly on matching the induced deformation prior to the target motion pattern, and support prior-deformation matching as a practical design principle for medical image registration. Our code will be available at https://github.com/HengjieLiu/RightPriorDIR.

Figures & tables

Explore similar work

CardsList
  1. LUMINR: Intensity-conditioned Meta-learned INRs for Accelerated Medical Image Registration

    Oct 16, 2026Damian Rynczak, Marek WodzinskiMedical Image RegistrationDeformable Image Registration

  2. An Accessible Solution for Deformable Image Registration Compared with Learning-Based Approaches

    Aug 3, 2026Onur Ali Zeybekoglu, David Tilly, Orcun GokselMedical Image RegistrationDeformable Image Registration

  3. FlexiMIND: Combined Pretrained Vision Features and Local Structure for Training-Free Deformable Medical Image Registration

    Oct 25, 2026Mojtaba Safari, Mingzhe Hu, Shansong Wang +6Medical Image RegistrationDeformable Image Registration