Abstract

Continuous wrist-worn hand sensing for gesture interfaces and motor symptom monitoring needs an always-on front end that fits inside a coin-cell power budget while pairing a micro-electro-mechanical-systems (MEMS) inertial measurement unit (IMU) with a 60 GHz frequency-modulated continuous-wave (FMCW) radar to stay robust under occlusion and on-body drift. We present a design study of such a wristband front end in which classifier wake-up gating, mmWave versus IMU routing, and innovation-based EKF measurement reweighting share a single on-chip residual generator. The shared generator occupies 14.4 KB of program memory and 278 B of state and runs at 110K multiply-accumulates (MACs) per frame on an Ambiq Apollo4 Blue Plus class edge microcontroller unit (MCU). Across four public sensor data corpora (IPN Hand, SHREC 2021, MiliPoint 60 GHz FMCW radar, EAT-Radar) the front end reaches detection probability PD=0.72/0.80P_D = 0.72/0.80 at a 1% false-alarm rate, sustains a 47% classifier invocation energy reduction at 90% gesture detection recall, and lowers pose tracking root-mean-square error by 4.6×4.6\times under measurement bias drift relative to an adaptive Kalman with RR-inflation baseline. Measured silicon power and on-body capture are deferred to follow-on hardware; the contribution here is a design study.

Figures & tables

Explore similar work

May 13, 2026

Efficient Sensor Fusion for Gesture Recognition on Resource-Constrained Devices

Gesture recognition is a cornerstone of Human-Computer Interaction (HCI) for smart eyewear, enabling natural and device-free control in augmented reality environments. Traditional vision-based approaches face significant challenges regarding power consumption, computational latency, and user privacy. This paper proposes a lightweight, privacy-preserving gesture recognition system based on the fusion of low-resolution Time-of-Flight (ToF) and Infrared (IR) thermal sensors. We used an 8 times 8 multizone ToF sensor (VL53L8CH) and an 8 times 8 IR array (AMG8833) to capture complementary depth and thermal cues. A compact Convolutional Neural Network (CNN) with a specialized grouped-convolution architecture is designed to fuse these modalities efficiently on a microcontroller (MCU). Experimental results on a custom dataset of 7 static gestures, validated via k-fold cross-validation, demonstrate that the proposed fusion strategy significantly outperforms single-sensor baselines with an accuracy of 92.3% and a macro F1-score of 0.93. Finally, on-device benchmarks on STM32F4 and STM32H7 MCUs confirm the system's suitability for resource-constrained wearables, requiring only 6,343 parameters and achieving millisecond-level inference latency with a total system power of 50 mW.
Dec 8, 2025

A Comparative Study of EMG- and IMU-based Gesture Recognition at the Wrist and Forearm

Gestures are an integral part of our daily interactions with the environment. Hand gesture recognition (HGR) is the process of interpreting human intent through various input modalities, such as visual data (images and videos) and bio-signals. Bio-signals are widely used in HGR due to their ability to be captured non-invasively via sensors placed on the arm. Among these, surface electromyography (sEMG), which measures the electrical activity of muscles, is the most extensively studied modality. However, less-explored alternatives such as inertial measurement units (IMUs) can provide complementary information on subtle muscle movements, which makes them valuable for gesture recognition. In this study, we investigate the potential of using IMU signals from different muscle groups to capture user intent. Our results demonstrate that IMU signals contain sufficient information to serve as the sole input sensor for static gesture recognition. Moreover, we compare different muscle groups and check the quality of pattern recognition on individual muscle groups. We further found that tendon-induced micro-movement captured by IMUs is a major contributor to static gesture recognition. We believe that leveraging muscle micro-movement information can enhance the usability of prosthetic arms for amputees. This approach also offers new possibilities for hand gesture recognition in fields such as robotics, teleoperation, sign language interpretation, and beyond.
May 28, 2026

Joint Angle Estimation with Customized Wristband Based on Online Incremental Learning

Intelligent wearable technology plays an increasingly important role in human-computer interaction, motion, and health monitoring. To ensure comfort and practicality of use, one common form for motion monitoring is to utilize soft wearable sensors. However, many research applications regarding wearable sensors are simplistic and difficult to adapt to different situations. This study proposes a system for estimating the angle of the wrist joint using a customized wristband based on an online incremental learning approach. It is a two-stage estimation method: the first stage updates the model based on the wearer's wrist movement characteristics using online learning, integrating real-time data from an IMU as ground truth. The second stage utilizes the updated model for estimation of wrist joint angle solely with the wristband. In other words, model training is completed during data acquisition, allowing the trained model to be used for subsequent angle estimation. This method offers advantages in adapting to data drift caused by variations in different testing configurations, such as the left and right wrists of the same subject, deviations in the wearing position on the same wrist, and even differences among various subjects. The results indicate that the sensors exhibit good performance under strain variations, and the wrist joint trajectory estimation of the proposed system has an approximate error of 15 degree in different scenarios.