CRS-Bench: A Reference-Relative Reliability Benchmark for Medical Image Encoders
Organizations: Vanderbilt University · Vanderbilt University Medical Center (VUMC)
Abstract
Pretrained image encoders are central to medical image classification, where expert annotation is costly and task-specific cohorts are often limited. As the model space expands from general-purpose to broad-medical and specialty-specific encoders, selecting the representation becomes a substantive modeling decision. Clean-test discrimination alone is insufficient for this purpose: encoders with similar AUROC can differ in calibration, label efficiency, and stability under acquisition perturbations or distribution shift. We introduce CRS-Bench, a controlled benchmark for multi-objective medical encoder selection. CRS-Bench evaluates 15 pretrained encoder families across dermatology, ophthalmology, and radiology using ISIC 2019, APTOS 2019, and CheXpert, with CheXpert-to-MIMIC-CXR as an observed institutional shift, yielding 17,575 controlled run records and 3,515 seed-aggregated metric rows. Each encoder is characterized along four operational reliability dimensions: discrimination, calibration, label efficiency, and robustness. We summarize these dimensions using the Clinical Reliability Score (CRS), a Pareto-aware, reference-relative score combining dominance, profile balance, and worst-axis performance. AUROC and CRS are positively associated but not decision-equivalent: 21 of 105 pairwise orderings reverse, with a mean absolute rank displacement of 1.87. Paired-seed bootstrap analysis identifies PanDerm, MedSigLIP, and MedGemma as a stable leading reliability tier rather than a statistically resolved single leader. CRS-Bench provides a controlled framework for selecting medical image encoders from multi-axis reliability profiles rather than clean-test AUROC alone.
Figures & tables
| Model | Pretraining data | Paradigm | Input | Domain |
| Generalist natural-image encoders | ||||
| ResNet-50 [ 9 ] | ImageNet-1K | Supervised | 224 | n/a |
| ViT-B/16 [ 5 ] | ImageNet-21K | Supervised | 224 | n/a |
| CLIP ViT-B [ 24 ] | WIT-400M | Contrastive | 224 | n/a |
| SigLIP ViT-B [ 30 ] | WebLI | Contrastive | 224 | n/a |
| DINOv2 ViT-B [ 21 ] | LVD-142M | Self-sup. | 224 | n/a |
| ISIC | APTOS | CheXpert | Aggregate | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Model | Grp | AUROC | CRS | AUROC | CRS | AUROC | CRS | AUROC | CRS | CI | |
| PanDerm | S | 0.957 | 0.583 | 0.922 | 0.685 | 0.733 | 0.346 | 0.871 | 0.703 | [0.600,0.720] | 0.66 |
| MedSigLIP | BM | 0.957 | 0.485 | 0.951 | 0.755 | 0.816 | 0.524 | 0.908 | 0.701 | [0.682,0.703] | 0.34 |
| MedGemma | MM | 0.960 | 0.333 | 0.958 | 0.763 | 0.808 | 0.359 | 0.909 | 0.645 | [0.598,0.647] | 0.00 |
| BiomedCLIP | BM | 0.899 | 0.449 | 0.908 | 0.454 | 0.812 | 0.246 | 0.873 | 0.424 | [0.406,0.522] | 0.00 |
| CheXzero | S | 0.886 | 0.253 | n/a | n/a | 0.788 | 0.418 | 0.837 | 0.398 | [0.391,0.403] | 0.00 |