cs.CVAug 25, 2026

Metadata-Aware Adaptation of a Generative Foundation Model for Conditional CMR Synthesis

Authors: Marc Rodríguez, Grzegorz Skorupko, Nay Aung, Steffen E Petersen, Karim Lekadir, Polyxeni Gkontra

Organizations: Facultat de Matem`atiques i Inform`atica, Universitat de Barcelona, Spain · Barcelona Artificial Intelligence in Medicine Lab (BCN-AIM), Facultat de Matem`atiques i Inform`atica, Universitat de Barcelona, Spain · William Harvey Research Institute, NIHR Barts Biomedical Research Centre, Queen Mary University London, Charterhouse Square, London, UK · Barts Heart Centre, St Bartholomew’s Hospital, Barts Health NHS Trust, West Smithfield, London, UK · Instituci´o Catalana de Recerca i Estudis Avanc¸ats (ICREA), Passeig Llu´ıs Companys 23, Barcelona, Spain

Abstract

Synthetic image generation is a promising strategy to address data scarcity and the underrepresentation of clinically important phenotypes in medical imaging, yet generating images that faithfully reflect meaningful patient characteristics remains challenging. In this work, we investigate metadata-conditioned cardiac magnetic resonance (CMR) synthesis using a pretrained latent diffusion model, encoding structured clinical metadata and slice position as textual prompts to guide CMR generation. To improve metadata adherence and address the imbalance of clinical attributes, we integrate three strategies: Metadata-Free Classifier-Free Guidance (CFG), Contrastive Batching, and Inverse-Frequency Sampling. The framework was fine-tuned and evaluated on 59,058 short-axis CMR from the UK Biobank using paired image similarity, distributional fidelity, and subgroup-level analyses. The combined approach achieved a Fréchet Inception Distance (FID) of 37.47, improving by 57.04% over the same model fine-tuned without these strategies and by 28.68% over a previous text-conditioned CMR diffusion baseline requiring cardiac geometry as additional input, while relying solely on patient metadata. This distributional gain, driven mainly by Metadata-Free CFG, came with a modest reduction in paired similarity, suggesting that the model prioritizes population-level realism over exact image reproduction. Subgroup analyses demonstrated improved alignment across demographic and acquisition-related metadata, with disease-specific conditioning being the most challenging task. These findings demonstrate the potential of generative foundation models for clinically meaningful CMR synthesis while highlighting the need for more effective metadata-aware conditioning strategies. Our code is available at https://github.com/rodriguezmarc/conditional-cmr.

Figures & tables

Explore similar work

CardsList
  1. Synthetic Cardiac MRI Image Generation using Deep Generative Models

    Mar 25, 2026Ishan Kumarasinghe, Dasuni Kawya, Madhura Edirisooriya +3Synthetic Data GenerationMedical Image Synthesis

  2. Temporally Consistent and Controllable Video Generation of 2D Cine CMR via Latent Space Motion Modeling

    Jun 8, 2026Yiheng Cao, Gustavo Andrade-Miranda, Jiatian Zhang +2Latent Dynamics ModelingText-to-Video Generation

  3. Balancing Fidelity, Utility, and Privacy in Synthetic Cardiac MRI Generation: A Comparative Study

    Mar 4, 2026Madhura Edirisooriya, Dasuni Kawya, Ishan Kumarasinghe +5Medical Image SynthesisSynthetic Data Augmentation