cs.ROAug 25, 2026

Fiber Optic Sensing Glove for High Performance Dexterous Manipulation Capture

Authors: J. D. Peiffer, Taylor Niehues, Li Guan, Ziyi Kou, Ergys Ristani

Organizations: Meta, Redmond, Washington, 98052, USA · Department of Biomedical Engineering, Northwestern University, Evanston, Illinois, 60208, USA · Work done at Meta

Abstract

Capturing hand pose during dexterous manipulation remains difficult: vision-based methods degrade under occlusion and challenging lighting, while sensorized gloves, though occlusion-free, are prone to drift and magnetic interference and rarely match motion-capture accuracy. We introduce a fiber optic sensing glove for full hand pose tracking that targets these failure modes, using multi-core shape-sensing fibers that capture each fiber's full 3D shape rather than curvature alone. A novel pipeline registers each reconstructed fiber shape to a common hand reference frame, and a new inverse-kinematics solver reconstructs full hand pose at 60 Hz using curve constraints. Benchmarked on a 2-hour dataset of dexterous object manipulation tasks across 5 subjects, the glove achieves 7.2 mm mean fingertip position error against motion capture ground truth, reduced to 4.9 mm by a one-time factory calibration of the fiber routing hub that transfers across users and sessions. These capabilities enable high-fidelity data capture and bimanual virtual teleoperation - both essential to advancing the robotics field.

Figures & tables

Explore similar work

Jul 16, 2026

KineFuse: Kinematic-Aware Haptic Fusion for In-Hand Occluded-Object Pose Tracking

Dexterous in-hand manipulation requires continuous 6D pose tracking, yet the manipulating fingers inevitably occlude the object from the camera. We study how to structure the sparse haptic signals already available on multi-fingered hands, including proprioception, proximal force/torque, and binary contact, to complement a pretrained visual pose tracker under occlusion. We propose a kinematic-aware finger-level encoder and systematically compare it against four alternative designs through three levels of evaluation: per-frame refinement, sequential open-loop tracking, and closed-loop manipulation. Our experiments reveal that (i) per-frame evaluation cannot distinguish encoder quality, while sequential tracking amplifies architectural differences by up to 15 times; (ii) the structured encoder learns task-specific cross-modal gating, using vision exclusively for translation and dedicating one attention head to haptics for rotation, without explicit supervision; and (iii) compact finger-level tokenization with 4 tokens outperforms both flat fusion and joint-level representations, which suppress vision through norm dominance. We validate that improved tracking yields higher success in a downstream reorientation task and provide qualitative real-world demonstrations. Our project page is available at https://cold-young.github.io/kine-fuse/.
Oct 4, 2026

VICON: Visual-Inertial-Contact based Hand-Object Tracking for Manipulation Datasets

Learning dexterous manipulation benefits from human demonstration datasets that capture diverse and natural hand-object interactions. In particular, contact points and forces provide supervision on where and how strongly to interact, which cannot be fully captured by motion trajectories alone. However, methods for jointly capturing hand and object motion, contact points, and forces remain limited. Moreover, severe occlusion from hand-object interaction challenges accurate tracking of both hands and objects. To address these limitations, we present a Visual-Inertial-CONtact based hand-object tracking (VICON) framework. It holistically captures both hand and object motion along with contact information during manipulation, even under severe occlusion. First, we adopt a visual-inertial glove and an RGB-D camera for accurate hand tracking, and redesign the glove to incorporate contact sensing. Specifically, force-sensitive resistors (FSRs) are placed on the glove based on human grasp frequency to synchronously record contact states and calibrated normal forces. Second, without requiring pre-existing CAD models, we estimate object poses using RGB-D images and a mesh reconstructed from a monocular video. We propose factor-graph-based object trajectory estimation that fuses object-pose estimates weighted by visibility under hand-object occlusion, FSR measurements, and a hand-motion prior. Across 40 motion-capture sessions with five objects, VICON achieves a 2.5% failed-frame rate compared with 50.9-64.6% for the baselines, with median errors of 3.9 mm and 3.0 degrees under occlusion. Using VICON, we construct a dataset containing synchronized hand-object motion, contact points, and normal forces, and will publicly release an expanded dataset covering 10 object categories at https://github.com/VICON-dataset/dataset.
Jul 25, 2026

Pose-Aware Modeling to Mitigate Pose-Related Artifacts in Tactile Gloves

Tactile gloves digitize contact and force during hand-object interactions, enabling robotics applications in dexterous manipulation, teleoperation, and learning from demonstration. To preserve hand dexterity and capture the nuances of natural interactions, these gloves and the integrated tactile sensors are designed to be soft, flexible, and comfortable. However, such flexible sensors are sensitive not only to contact forces but also unavoidably to hand pose changes, resulting in pose-related artifacts (PRAs). PRAs are especially problematic in the low-force range, resulting in misdetections or late-onset detections of contact, which raises the minimum detectable force (MDF) of the glove. In this work, we characterize the PRAs in relation to pose and force. Building on these insights, we introduce a glove-agnostic algorithmic framework that leverages hand pose information, which is increasingly available, to mitigate PRAs without glove modifications. Our pose-aware force estimation model augments tactile-to-force pipelines with a residual prediction branch that explicitly accounts for pose-induced sensor deformations. We validate our approach across 3 glove designs and 15 users, reducing MDF by 10.4%, 12.2%, and 18.3%, with consistent improvements across all evaluated metrics. This method provides a practical path to improving the usability of tactile gloves in data collection and diverse robotic applications.