cs.LGAug 28, 2026

Spectral Features Dominate BCG Respiratory-Event Detection: A Large-Scale Patient-Independent Comparison of Feature Groups in Sleep Apnea Patients

Authors: Israel Campero Jurado, Zoe Bousraou, Lara Benning, Sara Padilla Neira, Alexander Breuss, Robert Riener, Esther Irene Schwarz, Elisabeth Wilhelm

Organizations: Department of Engineering and Technology Institute Groningen, Faculty of Science and Engineering, University of Groningen, The Netherlands · Department of Pulmonology, University Hospital Zürich, Switzerland · Sensory-Motor Systems Lab, ETH Zürich, Switzerland

Abstract

Unobtrusive ballistocardiographic (BCG) sensing is a promising modality for long-term sleep-apnea monitoring, yet it remains unclear which signal features are most discriminative for respiratory-event detection. We present a literature-guided, patient-independent comparison of ten BCG feature groups using a 512-sensor capacitive pressure mat recorded simultaneously with respiratory polygraphy in 155 patients (52 female, 103 male) undergoing in-hospital evaluation for obstructive sleep apnea. Features were extracted from six spatially distinct signal channels, yielding a 191-dimensional feature vector spanning general statistical, time-domain, frequency-domain, wavelet, frame-energy, and nonlinear complexity descriptors. Under strict leave-one-patient-out cross-validation for binary classification of respiratory-event windows versus event-free reference windows, Random Forest and Histogram Gradient Boosting achieved AUC-ROC of 0.967 and 0.969 and AUC-PR of 0.977 and 0.979, respectively. Feature-importance analysis revealed that frequency-domain features dominate discrimination: breathing-band power in the 0.1-0.4 Hz range accounted for 30.3% of total discriminative information across all spatial channels, and Fast Fourier Transform spectral-shape descriptors of the adaptively preprocessed channel contributed a further 15.1%. AUC and curve-length features provided the main complementary time-domain evidence (21.5%), whereas wavelet-derived and nonlinear features contributed smaller secondary effects (10.4% combined across 59 features). Frequency-domain and time-domain features together accounted for 67% of total discriminative information, demonstrating that a compact, interpretable subset of the full feature library achieves clinically relevant performance under patient-independent validation and providing an empirical basis for feature selection in future BCG systems.

Figures & tables

Explore similar work

Oct 11, 2026

Sleep Sound Event Detection Powered by Learnable Multi-Resolution Adaptive Line Enhancer

Sleep-disordered breathing, including snoring, hypopnea, and obstructive apnea, is the hallmark of obstructive sleep apnea, whose severity is quantified by the Apnea-Hypopnea Index (AHI). As conventional polysomnography is costly and clin- ically demanding, microphone-only detection has emerged as a noninvasive alternative for screening. We propose ALE- Confidence Fusion Sound Event Detection (ACF-SED), the first framework that directly injects the per-frame confidence map of an Adaptive Line Enhancer (ALE) into Transformer atten- tion biasing and feature modulation, rather than as mere pre- processing. A Multi-Resolution ALE Bank aggregates three parallel NLMS filters at distinct decorrelation delays, while a Confidence-Guided Cross-Path block couples event and noise streams via gated cross-attention. On the Audio-Polygraphy Dataset for Sleep Apnea Analysis, ACF-SED achieves state- of-the-art detection across Event-F1, Segment-F1, and PSDS, enabling end-to-end AHI estimation.
Jun 23, 2026

BCoughBench: Benchmarking Respiratory Acoustic Foundation Models Under Body-Coupled Wearable Sensor Conditions

Respiratory acoustic foundation models (FMs) are benchmarked exclusively on smartphone recordings, yet clinical deployment increasingly targets body-coupled (BC) wearables whose sensors attenuate high-frequency content through tissue and bone, leaving FM reliability uncharacterised. We introduce BCoughBench, evaluating five FMs (OPERA-CT/CE/GT, HeAR, M2D+Resp) on nine classification tasks (AUROC, sensitivity at 95% specificity, Expected Calibration Error) and three age regression tasks (MAE vs. a mean-predictor baseline) across five EBEN-simulated BC sensor conditions on five labeled cough datasets. Mean AUROC declines from 0.785 (smartphone) to 0.689-0.723, degrading most under temple vibration pickup (ΔΔ = -0.096) and least under the soft in-ear (ΔΔ = -0.062). No FM meets the clinical sensitivity threshold (Se@Sp95 ≥\geq 0.20) on most disease tasks under any BC sensor. Sex classification on the CIDRZ cohort collapses (AUROC 0.954 to 0.596-0.628, ΔΔ = -0.341) while COVID detection is nearly unaffected (ΔΔ = -0.004). Age regression is robust, improving under the forehead accelerometer on CoughVID (MAE 9.61 to 8.97 yr); HeAR leads on regression and demographic tasks, M2D+Resp on disease and characteristic tasks. BCoughBench provides a reproducible framework for FM evaluation under wearable conditions.
Jun 5, 2026

BCG-FM: A Foundation Model for Ambient Cardiac Health Sensing

Foundation models for wearable biosignals have matched or exceeded supervised specialists across a range of clinical tasks, yet all rely on modalities that require deliberate user action--wearing a device or visiting a sleep lab. We introduce BCG-FM, the first foundation model for ambient mechanical biosignals. A piezoelectric sensor embedded in the bed surface records ballistocardiography (BCG) each night without user effort; we pretrain BCG-FM with participant-level contrastive learning and using a total of 2.75 million hours of nightly recordings from 145,985 individuals, the largest raw-waveform biosignal pretraining corpus to date. Frozen BCG-FM embeddings achieve 3.26-year MAE on biological-age estimation (the lowest reported for any ambient, contactless modality) and yield clinically relevant discrimination across 15 self-reported health conditions and three independent external cohorts. Pretrained representations from only 500 labeled participants outperform a fully supervised baseline trained on 3,372, and representation quality scales log-linearly with contrastive batch size. These results establish ambient, longitudinal mechanical biosignals as a viable modality for health foundation models.