Manifold-Constrained PET Reconstruction with Learned Flow-Matching Priors

Authors: Hengjia Ran, Jie Luo, Yutao Zhu, Rui Hu, Fenglin Zhan, Jianyong Jiang, Huafeng Liu, Bo Zhao

Organizations: ZJU-UIUC Institute, Zhejiang University, Haining 314400, China · College of Information Science and Electronic Engineering, Zhejiang University, Hangzhou 310027, China · College of Optical Science and Engineering, Zhejiang University, Hangzhou 310027, China · Vivo Mobile Communication Co., Ltd., Hangzhou 311100, China · 

Abstract

Image reconstruction for positron emission tomography (PET) is an ill-posed Poisson inverse problem. In this work, we introduce an unsupervised, optimization-based reconstruction framework that employs a flow-matching generative model as a learned manifold prior. We train the generative model on high-quality PET images to learn a differentiable ordinary differential equation (ODE)-based transport from a Gaussian latent distribution to the PET image distribution. We incorporate this generator as an explicit manifold constraint into a regularized Poisson likelihood formulation. To solve the resulting problem, we develop an alternating direction method of multipliers (ADMM) algorithm that integrates an expectation-maximization (EM)-type surrogate update for Poisson data fidelity with gradient-based latent-space optimization. Numerical simulations and in vivo PET experiments demonstrate improved reconstruction accuracy compared with conventional reconstruction methods and recent deep learning-based approaches, particularly in low-count settings, with competitive computational efficiency.

Figures & tables

Explore similar work

Oct 30, 2026

Bayesian PET Reconstruction with Learned Flow Matching Priors via Langevin Sampling

Image reconstruction for positron emission tomography (PET) is a challenging inverse problem due to its inherent ill-posedness and Poisson counting noise, particularly in low-dose acquisitions. In this work, we introduce a novel Bayesian PET reconstruction framework that leverages a flow-matching generative prior learned from high-quality PET images. By incorporating this prior, we formulate PET reconstruction as a Bayesian inference problem and solve it via latent-space posterior sampling using the unadjusted Langevin algorithm. We evaluate the proposed method through numerical experiments and benchmark it against classical reconstruction methods and state-of-the-art deep learning-based baselines. The proposed method achieves improved reconstruction performance while enabling posterior uncertainty quantification.
Aug 20, 2026

Flow Matching-Based PET Image Reconstruction

Generative models have shown strong potential for positron emission tomography (PET) image reconstruction. Although diffusion model-based reconstruction methods have demonstrated promising performance, they often require many reverse sampling steps with data-consistency updates incorporated into the sampling process. Flow matching offers an attractive alternative because it can directly estimate clean images from intermediate states, allowing data-consistency refinement to be separated from flow propagation. In this work, we proposed flow matching-based PET image reconstruction methods. We first established PET-FlowDPS by incorporating Poisson likelihood guidance with an expectation-maximization (EM)-based preconditioner into the FlowDPS framework. We then proposed a model-based PET reconstruction method that used a pretrained flow matching model as a prior, in which the flow-based prior, PET data refinement, and stochastic propagation were interpreted within an approximate Bayesian framework. Experimental results using [18F^{\text{18}}\text{F}]FDG brain PET datasets showed that the proposed method achieved better bias-variance trade-offs across different dose levels compared with other reference methods. These results demonstrated the potential of flow matching as a generative prior for quantitative PET image reconstruction.
Jul 13, 2026

FlowPET: Physics-Informed Symplectic Flow Matching for Low-Count PET Reconstruction

Low-count Positron Emission Tomography (PET) reconstruction is severely hindered by the dissipative nature of prevailing generative models, where the inherent phase-space contraction leads to the numerical extinction (``wash-out'') of weak but diagnostically critical lesion signals. To overcome this geometric limitation, we propose FlowPET, a physics-informed framework that reformulates reconstruction as volume-preserving transport in a symplectic phase space. By parameterizing the posterior dynamics via a Separable Hamiltonian System, our approach guarantees a divergence-free vector field by construction, theoretically immunizing weak signals against probability mass collapse. To steer this conservative flow, we introduce conjugate boundary conditions based on the Range-Null space decomposition of the PET operator; this strictly enforces data consistency in the range space while confining stochastic uncertainty injection to the unobserved null space. We train the model via symplectic flow matching and perform inference using a symplectic leapfrog integrator. Extensive experiments on BrainWeb, clinical pediatric, and UDPET datasets demonstrate that FlowPET not only surpasses state-of-the-art deterministic and stochastic baselines in SSIM and PSNR but, more crucially, exhibits superior recovery of low-contrast lesions. The results confirm that imposing Hamiltonian structural constraints offers a robust geometric safeguard for medical inverse problems in high-noise regimes.