Toward Trustworthy Robot-Assisted Sliding Palpation for Shallow Vessel Localisation with a Calibrated Digital Twin

Authors: Piotr Blaszyk, Wen Fan, Kaizhong Deng, Daniel Elson, Dandan Zhang

Organizations: Imperial College London, UK

Abstract

Reliable localisation of shallow subsurface vessels is important for safe robot-assisted venous access and vessel-aware manipulation, but collecting diverse tactile data on physical hardware is costly, time-consuming, and can degrade soft vision-based tactile sensors. We present a robot-assisted sliding-palpation framework in which a calibrated digital twin generates labelled tactile sequences, reducing reliance on real-world data. The twin models sensor-vessel contact, is calibrated against real palpation trajectories using Bayesian-optimisation-based domain adaptation, and is randomised over sliding direction and contact conditions. A spatio-temporal graph neural network trained on simulated marker trajectories performs per-node vessel classification and produces a human-verifiable top-view localisation map through 2D-to-3D-to-2D geometric projection. We evaluate three datasets: Sim, Silicone, and Meat, the latter a raw-meat phantom with vessel models at nominal depths of 0 to 30 mm, using four train-to-test configurations: Sim to Sim, Sim to Silicone, Sim to Meat, and Meat to Silicone. The calibrated twin achieves a simulated-to-real marker-alignment mean absolute error of 0.50 mm at deepest contact across four canonical interactions. After reprojection onto a 1 mm top-view grid, predicted vessel pixels lie on average 1.05 to 5.49 mm from the nearest true vessel pixel across the four models, with 1.05 to 1.31 mm for all except Sim to Meat. The larger error for Sim to Meat reflects the greater domain shift and current limit of simulation transfer. These results demonstrate progress toward trustworthy tactile palpation through calibrated simulation, interpretable localisation, and transparent cross-domain evaluation. Code, model weights, and data are publicly available on GitHub and Zenodo.

Figures & tables

Explore similar work

Aug 18, 2026cs.RO

Transferable Tool-Tissue Contact Detection from Stereo Depth in Robot-Assisted Surgery

Reliable tool--tissue contact detection can support interaction-aware control and downstream force estimation in robot-assisted surgery. Most existing methods learn a contact classifier from RGB appearance, which is hard to generalize. In this work, we use the depth image generated from a stereo pair to give more information about tool--tissue contact. For each depth frame, we localize a spatially supported minimum-distance patch around the tool boundary and reduce it to a single scalar, −log⁡10∣d∣-\log_{10}|d|; this signal rises and falls in step with ground-truth contact. We formalize this observation with a fully supervised two-state hidden Markov model. We fit this model as a six-fold leave-one-session-out (LOSO) ensemble on six palpation sessions against a single silicone cup-like phantom, with the decision threshold selected from the pooled out-of-fold predictions. It is evaluated on four held-out sessions of three categories: 1. same task on same phantom; 2. same task on different phantom; 3. different task on different phantom. This model reaches held-out macro F1 0.9270.927 and AUPRC 0.9800.980. We further compare against a reproduction of an RGB-based contact classifier from prior work. This RGB-based model achieves high performance on the first category (F1 0.9650.965), but substantially lower performance on the other two, resulting in macro F1 0.3200.320 across all four sessions. These results indicate that the tool--tissue distance is a strong, transferable cue for contact detection in robot-assisted surgery.
Oct 5, 2026cs.RO

Demo: Vision-Language Model-Guided Online Calibration of an Electromagnetic Digital Twin

An electromagnetic (EM) digital twin gives mobile robots wireless situational awareness but depends on material conductivities that change with the environment. Online calibration faces initialization sensitivity and measurement travel costs. We demonstrate a vision-language model (VLM)-guided framework using a Unitree G1 robot and NVIDIA Sionna, with two VLM calls: material classification maps visible materials through ITU-R P.2040 to conductivity priors for Sionna's gradient descent on accumulated received signal strength (RSS) measurements; waypoint planning selects the next measurement location online using residual RSS calibration error and image coverage. In a real indoor scenario, the framework achieves a normalized mean absolute conductivity error of 1.74×10−41.74\times10^{-4} within 20 m of travel; random initialization never converges, while random waypoints require over twice the travel.
Sep 18, 2026cs.RO

Tracker-Free Robotic Ultrasound Calibration with a Spherical-Marker Phantom and Threshold-Free Center Localization

Robotic ultrasound (US) calibration is essential for accurately relating US images to the robot coordinate system, but accurate and automated calibration remains challenging because existing methods often require complex phantoms or external 3D trackers. In this work, we develop a tracker-free robotic US calibration framework using a spherical-marker phantom and a highly automated perception pipeline for sphere-center localization. The proposed threshold-free image-processing method localizes the spherical feature based on each US image's intensity distribution, eliminating hand-tuned intensity thresholds and improving robustness across imaging settings without per-system retuning. Multi-pose observations of the spherical fiducial are then used to estimate the US-to-EE transformation without external tracking or prior localization of the sphere center in the robot base frame. We validate the proposed framework on a robotic US platform through repeated sphere scans and further assess the calibrated system using geometrically distinct phantoms with known CAD models. Across 12 cross-validation folds, single-marker calibration achieved sphere-center accuracy and precision of 1.75±0.511.75\pm0.51 mm and 0.85±0.110.85\pm0.11 mm, respectively, compared with 1.72±0.511.72\pm0.51 mm and 0.84±0.120.84\pm0.12 mm for three-marker calibration. Across the three reconstruction sets, the single-marker calibration yielded pooled post-registration point-to-surface MAE±\pmSD values of 0.41±0.350.41\pm0.35 mm for the cone and 0.50±0.410.50\pm0.41 mm for the triangular prism, closely matching the three-marker results of 0.40±0.350.40\pm0.35 mm and 0.48±0.400.48\pm0.40 mm, respectively.