Tracker-Free Robotic Ultrasound Calibration with a Spherical-Marker Phantom and Threshold-Free Center Localization

Authors: Kyoungmo Koo, Guangshen Ma, Xueding Wang, Mark Draelos

Organizations: Department of Robotics, University of Michigan, 2505 Hayward St, Ann Arbor, MI 48109, USA · Department of Biomedical Engineering, University of Michigan, 1150 Medical Center Dr, Ann Arbor, MI 48109, USA · Department of Ophthalmology and Visual Sciences, University of Michigan Medical School, 1000 Wall St, Ann Arbor, MI 48105, USA

Abstract

Robotic ultrasound (US) calibration is essential for accurately relating US images to the robot coordinate system, but accurate and automated calibration remains challenging because existing methods often require complex phantoms or external 3D trackers. In this work, we develop a tracker-free robotic US calibration framework using a spherical-marker phantom and a highly automated perception pipeline for sphere-center localization. The proposed threshold-free image-processing method localizes the spherical feature based on each US image's intensity distribution, eliminating hand-tuned intensity thresholds and improving robustness across imaging settings without per-system retuning. Multi-pose observations of the spherical fiducial are then used to estimate the US-to-EE transformation without external tracking or prior localization of the sphere center in the robot base frame. We validate the proposed framework on a robotic US platform through repeated sphere scans and further assess the calibrated system using geometrically distinct phantoms with known CAD models. Across 12 cross-validation folds, single-marker calibration achieved sphere-center accuracy and precision of 1.75±0.511.75\pm0.51 mm and 0.85±0.110.85\pm0.11 mm, respectively, compared with 1.72±0.511.72\pm0.51 mm and 0.84±0.120.84\pm0.12 mm for three-marker calibration. Across the three reconstruction sets, the single-marker calibration yielded pooled post-registration point-to-surface MAE±\pmSD values of 0.41±0.350.41\pm0.35 mm for the cone and 0.50±0.410.50\pm0.41 mm for the triangular prism, closely matching the three-marker results of 0.40±0.350.40\pm0.35 mm and 0.48±0.400.48\pm0.40 mm, respectively.

Figures & tables

Explore similar work

Jul 14, 2026cs.CV

Seeing Globally, Refining Locally: Global Visual Guidance and Local Ultrasound Cues for Robust Freehand 3-D Ultrasound Reconstruction

Freehand 3-D ultrasound (US) imaging has attracted increasing attention owing to its intuitive volumetric visualization, ease of use, and low cost. However, accurate 3-D reconstruction critically depends on stable probe pose estimation, yet existing trackerless methods remain susceptible to accumulated pose errors, particularly over long scanning trajectories. To address this limitation, we propose a global-to-local pose estimation framework that exploits external camera observations for globally stable localization and B-mode US images for anatomy-aware local refinement. Specifically, the framework comprises a dual-camera branch that performs contextual feature aggregation across camera views and temporal observations to estimate a globally consistent probe trajectory, and a B-mode branch that performs anatomical feature aggregation from sequential US images to capture tissue-dependent local motion cues. A cross-modal fusion module subsequently integrates the contextual camera features and anatomical US features to predict pose residuals and refine the camera-derived estimates in the transformation space. Furthermore, a multi-scale pose loss constrains relative motion over multiple temporal horizons to suppress accumulated drift during extended scans. The proposed framework is validated on phantom and in vivo datasets. On two in-house datasets (FUSION-J and FUSION-L) collected using different machines, the proposed US + Dual-Cam model reduces average trajectory drift to 1.67 mm and 1.29 mm, representing improvement of 16.50% and 27.12%, respectively, over a strong dual-camera baseline, while substantially outperforming US-only pose estimation (>13 mm drift). In in vivo forearm arteries reconstruction, it achieves Hausdorff distances of 1.58 mm, demonstrating the effectiveness of the proposed method on real clinical scenarios.
Aug 11, 2026cs.RO

From Self-Normal-Positioning to Omni-Directional Tracking: Real-Time Surface Modeling Enabled Probe Tilt Control for Robotic Ultrasound Imaging

Ultrasound (US) provides real-time, radiation-free imaging, but the image quality depends strongly on how the probe is oriented against the patient body. Robotic US can reduce operator workload and improve acquisition consistency; however, most existing systems focus on normal positioning, where the probe is maintained perpendicular to the local surface. This constraint is inadequate for examinations like echocardiography, where obtaining a diagnostic view requires a non-normal probe angle. Consequently, a clinically useful robotic system must sense the local surface in real-time and preserve the desired probe orientation. Here, we propose an omni-directional probe-orientation control framework that integrates RGB-D perception, local-surface modeling, and task-space orientation control. The surface model fuses multi-view point clouds and provides a quadratic estimate of the local surface. A desired imaging direction is then encoded relative to the normal, enabling the probe to track arbitrary angles. The framework was evaluated through flat-surface tracking, phantom target-angle recovery, and in-vivo tracking of an expert selected view. Results show that the mean angular tracking error was 1.06 +- 0.66 deg. The system recovered a non-normal tilt angle of up to 44.39 +- 2.59 deg relative to the surface normal, and acquired the desired heart chamber view in the phantom and in-vivo experiments.
Apr 29, 2025cs.RO

Hydra: Marker-Free RGB-D Hand-Eye Calibration

This work presents an RGB-D imaging-based approach to marker-free hand-eye calibration using a novel implementation of the iterative closest point (ICP) algorithm with a robust point-to-plane (PTP) objective formulated on a Lie algebra. Its applicability is demonstrated through comprehensive experiments using three well known serial manipulators and two RGB-D cameras. With only three randomly chosen robot configurations, our approach achieves approximately 90% successful calibrations, demonstrating 2-3x higher convergence rates to the global optimum compared to both marker-based and marker-free baselines. We also report 2 orders of magnitude faster convergence time (0.8 +/- 0.4 s) for 9 robot configurations over other marker-free methods. Our method exhibits significantly improved accuracy (5 mm in task space) over classical approaches (7 mm in task space) whilst being marker-free. The benchmarking dataset and code are open sourced under Apache 2.0 License, and a ROS 2 integration with robot abstraction is provided to facilitate deployment.