cs.CVSep 6, 2026

One Shared LoRA Weight for MRI Reconstruction across Acceleration Factors

Authors: Zhiwei Zhao, Weikang Gong, Zhongnian Li, Xinzheng Xu

Organizations: School of Computer Science and Technology / School of Artificial Intelligence, China University of Mining and Technology, Xuzhou, China

Abstract

Accelerated MRI reconstruction recovers images from undersampled k-space. However, different acceleration factors produce distinct artifact patterns. Existing methods often train separate models for each factor, leading to poor cross-factor generalization and high training and storage costs. We propose Shared LoRA, a parameter-efficient framework that freezes the pretrained SHFormer backbone and trains a single shared set of LoRA adapters together with a lightweight gating network. During training, undersampled inputs are generated by randomly sampling acceleration factors and their corresponding sampling masks, enabling the shared adapters to learn reconstruction knowledge across factors. Given the acceleration factor, GateNet generates layer-wise coefficients to dynamically modulate the residual strength of each adapter. Experiments show that Shared LoRA achieves the best or competitive PSNR and SSIM across acceleration factors, while its trainable parameters account for only about 5.3% of the total model parameters. Its performance at lower acceleration factors remains largely unaffected as the jointly trained factor set expands, and it generalizes stably to unseen neighboring factors.

Figures & tables

Explore similar work

May 19, 2026

Next-Acceleration-Scale Prediction for Autoregressive MRI Reconstruction

MRI reconstruction is an inherently ill-posed inverse problem, since incomplete measurements admit many plausible solutions. This ambiguity becomes more severe under high acceleration, where pixel-domain continuous predictors tend to average over feasible reconstructions and suppress high-frequency anatomy. We address this limitation by moving reconstruction to discrete multi-scale latent space and posing it as autoregressive next-acceleration-scale prediction. Leveraging discrete priors proven effective in visual autoregressive modeling, our method restricts the solution to compact sequences of codebook tokens, enabling sharp reconstructions even from extremely sparse measurements. This discrete autoregressive formulation also aligns naturally with modern large language model post-training techniques. Building on this observation, we introduce on-policy privileged information distillation for visual autoregressive modeling, where a teacher is provided training only privileged context that is unavailable at inference, in our case fully sampled acquisitions, and supervises a student trained on its own rollouts, leading to consistent reconstruction gains. Through extensive experiments on the fastMRI benchmark, we show that our approach delivers improved reconstruction performance across diverse sampling patterns under extreme undersampling. Project website is here.
Sep 21, 2026

SGAM: Shared Gaussian Geometry with Implicit Amplitude Modeling for Scan-Specific 3D Multi-Contrast MRI Reconstruction

Three-dimensional (3D) multi-contrast magnetic resonance imaging (MCMRI) provides rich anatomical and quantitative information but requires long acquisition times, motivating k-space undersampling. However, reconstruction of large volumetric datasets imposes substantial computational and memory demands. To address this challenge, we propose SGAM, a memory-efficient, scan-specific framework for joint full-volume 3D MCMRI reconstruction. SGAM is based on a shared-geometry Gaussian representation in which amplitudes are modeled by a multi-output implicit neural representation (INR) and contrast-specific phases by explicit variables. This design exploits common anatomical structure across contrasts while preserving contrast-specific signal variations. The representation is jointly optimized using only the acquired multi-coil k-space without external training data. Experiments showed that SGAM consistently outperformed the comparison methods across imaging tasks and acceleration factors, with greater improvements under stronger undersampling. SGAM also achieved a favorable balance between reconstruction quality and computational cost, demonstrating its effectiveness for 3D multi-contrast MRI reconstruction.
Aug 14, 2026

UMPIRE-Net: Unrolled Magnitude-Phase Regularization Network for Accelerated MRI

MRI reconstruction from undersampled k-space measurements is an ill-posed inverse problem. Physics-driven deep learning (PD-DL) methods have shown strong performance for this task by combining the MRI forward model with learned image regularization within algorithm-unrolling frameworks. However, most existing PD-DL methods reconstruct complex-valued images directly, thereby implicitly coupling magnitude and phase within a single learned representation. This coupled regularization may be suboptimal in reconstruction settings where accurate phase modeling plays an important role, such as partial Fourier (PF) imaging, where recovery of the omitted asymmetric k-space measurements depends on the underlying image phase. In such scenarios, explicit modeling of magnitude and phase as separate components may reduce the reliance on externally estimated or predefined phase information. To this end, we propose UMPIRE-Net (Unrolled Magnitude-Phase In REgularization Network), a PD-DL method that introduces separate learned regularizers for magnitude and phase components, together with a novel data-fidelity formulation that enforces measurements consistency. We evaluate UMPIRE-Net for accelerated MRI with PF across different datasets and acceleration factors. Experimental results demonstrate that our proposed method improves reconstruction quality compared with a conventional complex-valued PD-DL baseline, yielding sharper images and reduced artifacts. Code available at: https://github.com/MahdiSaberii/UMPIRE-Net