ARNAI: Artifact Removal Network based on Autoencoding and Inpainting for Robust Spinal Image Segmentation and Measurement

Authors: Sang-Jin Park, Jinyoung Choi, Seokwon Kim, Seungeon Song, Insu Park, Dougho Park, Taeyeon Kim, Youjin Lee, 

Organizations: Pohang Stroke and Spine Hospital, Pohang, Republic of Korea · School of CSEE, Handong Global University, Pohang, Republic of Korea · School of Convergence Science and Technology, Pohang University of Science and Technology, Pohang, Republic of Korea · Department of Neurosurgery, Kyungpook National University Hospital, Kyungpook National University College of Medicine, Daegu, Republic of Korea

Abstract

Purpose: This study aims to develop an AI framework applicable for postoperative imaging for automated measurement of spinopelvic parameters on radiographs with robustness to the presence of spinal implants. Materials and Methods: We retrospectively reviewed lateral lumbar spine radiographs from two institutions (Internal: January 2017--December 2024; External: October 2021--September 2025). We developed the Restore, Segment, and Measure (RSM) framework, incorporating a novel Artifact Removal Network based on Autoencoding and Inpainting (ARNAI) to mitigate implant-related artifacts in postoperative radiographs. Segmentation and spinopelvic parameter (PT, LL, SS, SCA) measurement performance were assessed using Wilcoxon signed-rank tests and intraclass correlation coefficients. Results: When ARNAI was added to a recent Transformer-based segmentation model, FCBFormer, the mean DSC increased to 0.870 from 0.814, with marked gains at L3--L5 and smaller improvements at L1--L2. On 91 radiographs with implants, the mean L4--L5 segmental Cobb angle error decreased to 4.7 ° from 15.6--16.2 °, an average error reduction of 70%. The ICC for L4--L5 segmental Cobb angle improved to 0.54 (Rater 1) and 0.59 (Rater 2) from 0.18, and ICCs for pelvic tilt, lumbar lordosis, and sacral slope all exceeded 0.70. The improvement in L4--L5 segmental Cobb angle error was statistically significant in the internal implant-containing cohort after correction for multiple comparisons. Conclusion: The proposed RSM framework improved automated spinopelvic parameter measurement in implant-containing postoperative radiographs. By mitigating implant-related artifacts, ARNAI improved segmentation and downstream measurement accuracy, with the greatest benefit observed for L4--L5 segmental Cobb angle estimation, where the mean error was reduced by approximately 70%.

Figures & tables

Explore similar work

Apr 10, 2026

Fine-Grained Action Segmentation for Renorrhaphy in Robot-Assisted Partial Nephrectomy

Fine-grained action segmentation during renorrhaphy in robot-assisted partial nephrectomy requires frame-level recognition of visually similar suturing gestures with variable duration and substantial class imbalance. The SIA-RAPN benchmark defines this problem on 50 clinical videos acquired with the da Vinci Xi system and annotated with 12 frame-level labels. The benchmark compares four temporal models built on I3D features: MS-TCN++, AsFormer, TUT, and DiffAct. Evaluation uses balanced accuracy, edit score, segmental F1 at overlap thresholds of 10, 25, and 50, frame-wise accuracy, and frame-wise mean average precision. In addition to the primary evaluation across five released split configurations on SIA-RAPN, the benchmark reports cross-domain results on a separate single-port RAPN dataset. Across the strongest reported values over those five runs on the primary dataset, DiffAct achieves the highest F1, frame-wise accuracy, edit score, and frame mAP, while MS-TCN++ attains the highest balanced accuracy.
Aug 5, 2026

Segmentation Pre-training for Label-Efficient Lumbar Spine Degeneration Grading

Automated assessment of degenerative pathology in the lumbar spine on magnetic resonance imaging (MRI) requires access to large-scale datasets of expert-annotated radiological gradings. In contrast, segmentation pseudo-labels can be generated by automated tools at negligible radiologist cost. We examine whether pre-training on segmentation can effectively replace a fraction of the manual grading annotations required for downstream supervision. We pre-train a 3D ResNet encoder to segment the vertebrae, intervertebral discs (IVDs), and the spinal canal, then fine-tune lightweight task-specific grading heads using different proportions of the available training data, ranging from 10%10\% to 100%100\%. On a multicentre dataset of ∼2,000{\sim}2{,}000 subjects across 11 pathologies, segmentation pre-training, achieving a Dice score of 0.940.94 against pseudo-labels, improved the task-averaged (macro) one-vs-rest ROC-AUC at all proportions. With only 20% of grading labels after pre-training, the method achieved near full-supervision performance, with the largest gains observed for either low-prevalence or spatially grounded pathologies.
Sep 4, 2026

ViT3Flow: A Test-Time Training Transformer MeanFlow for Postoperative Radiograph Synthesis in Scoliosis

Predicting postoperative spinal morphology from preoperative radiographs could provide valuable support for scoliosis surgical planning, but remains challenging because surgical correction induces large spatial changes while anatomical structures must be faithfully retained. We formulate this problem as postoperative scoliosis radiograph synthesis and construct ScoliSurg, the first paired dataset for this task, comprising 632 preoperative--postoperative whole-spine radiograph pairs with structured morphology information. We further propose ViT3^{3}Flow, a single-NFE conditional MeanFlow framework for efficient postoperative radiograph synthesis. ViT3^{3}Flow models surgical correction as finite-interval generative transport and replaces conventional self-attention with test-time-training token mixers that perform sample-specific inner adaptation to the anatomy and deformity pattern of each case. In addition, a Spinal Morphology Extraction Agent extracts distributions of dominant-curve region and direction from the preoperative radiograph. These distributions guide Diagnosis-Routed Interval Cross-Attention (DRICA), which performs interval-dependent vertical, horizontal, joint, and global retrieval from a separate preoperative token stream. This design enables the evolving postoperative representation to incorporate spatially corresponding anatomical evidence throughout the transport process. Extensive experiments on ScoliSurg demonstrate that ViT3^{3}Flow achieves the best performance among the compared methods in perceptual image quality, anatomical fidelity, and clinically relevant geometric accuracy, while requiring only a single network evaluation. These results highlight the potential of ViT3^{3}Flow for efficient and anatomically faithful postoperative radiograph synthesis in scoliosis surgical planning.