cs.LGSep 9, 2026

NEXUS-MI: Communication-Aware Federated Personalization for Gateway-Coordinated Motor-Imagery Brain-Computer Interfaces

Authors: Daniel Adu WoraeAarthy Nagarajan

Abstract

Electroencephalography (EEG)-based motor-imagery brain-computer interfaces (MI-BCIs) vary across subjects and sessions, complicating personalization from limited calibration data. Federated learning can exploit shared representations without centralizing raw EEG, but existing federated MI studies largely assume regular synchronization. We introduce NEXUS-MI, a gateway-coordinated federated personalization framework that treats synchronization as a coupled learning-and-communication control problem. Raw EEG and classifier heads remain local, while an edge coordinator maintains the shared backbone. We evaluate NEXUS-MI through offline replay using BCI Competition IV Dataset 2a (BCICIV-2a; 9 subjects, 4 classes) and OpenBMI (54 subjects, 2 classes). Session 1 supports backbone learning, and Session 2 provides limited-calibration personalization and held-out testing. An ideal-link reference and six heterogeneous-link policies characterize gateway participation, buffering, stale-update admission, and backbone-download control. The principal comparison holds delayed-update handling fixed while contrasting non-adaptive and communication-aware synchronization. Paired subject-level comparisons use Holm adjustment, and robustness across five matched realizations is assessed by hierarchical bootstrap. Communication-aware coordination reduced server-to-client backbone traffic by approximately 42% on both datasets, while cohort-level accuracy differences were small and realization-dependent. Cohort averages also concealed subject-level vulnerability, with losses reaching approximately 12 percentage points on BCICIV-2a relative to the ideal-link reference. These findings establish gateway synchronization as an explicit design variable in federated MI personalization and motivate joint evaluation of personalized accuracy, communication cost, update freshness, and subject-level reliability.

Explore similar work

Jun 23, 2026cs.HC

Average Rankings Mask Per-Subject Optimality: A Friedman-Nemenyi Benchmark of EEG Motor-Imagery BCI Decoders

Electroencephalography (EEG) is the dominant non-invasive modality for brain-computer interfaces (BCIs), yet reliable decoding of motor imagery is hampered by inter- and intra-individual variability. A recurring claim is that one decoding pipeline, most often a spatial or Riemannian method, is broadly preferable. We test the weakest version of that claim under the most favourable conditions. Using the Mother of All BCI Benchmarks (MOABB) framework, we evaluated 1,056 decoding configurations (feature extractor x scaler x classifier), >340,000 subject-level model fits, across three public left-versus-right motor-imagery datasets (PhysionetMI, 109 participants; Cho2017, 52; Zhou2016, 4) and two frequency bands (8-15 Hz, 8-30 Hz). Every model is fit and tested within a single session of a single participant, the easiest regime, giving every pipeline its best chance. We apply the statistics standard for multi-classifier comparison: Friedman omnibus tests, Nemenyi critical-difference analysis and Wilcoxon signed-rank tests with effect sizes. Covariance tangent-space projection (cov-tgsp) and Common Spatial Patterns (CSP) are the strongest families, but their ordering is dataset-dependent and, on the largest and most heterogeneous cohort (PhysionetMI), statistically indistinguishable (Nemenyi p = 0.27; Kendall's W = 0.11). At the individual level the single best pipeline is optimal for only 35% of PhysionetMI participants, and nonlinear descriptors are best for roughly one third; matching pipeline to participant adds about seven accuracy points over the best fixed choice. The ranking is not an artefact of dimensionality, and classifier and scaler choices are secondary to the feature representation. Even in the easiest regime, no single pipeline dominates: a lower bound on the personalization problem and a quantitative case for participant-aware model selection rather than a universal decoder.
Xavier Vasques, Paul Barbaste, Olivier Oullier
Jul 26, 2026cs.CV

ATCNet-CIAM for Multi-Session Motor Imagery EEG Signal Classification

Motor imagery (MI)-based electroencephalography is widely used in non-invasive brain--computer interfaces (BCIs), but robust decoding remains challenging due to inter-subject variability and cross-session non-stationarity. This work proposes ATCNet-CIAM, an enhanced attention temporal convolutional network that integrates a lightweight channel-integrated attention module (CIAM) into the ATCNet framework to improve channel-spatial feature representation for MI decoding. The proposed model is evaluated on BCI Competition IV-2a, BCI Competition IV-2b, and the multi-day WBCIC-MI dataset under standard, within-session, and cross-session protocols. Experimental results show that ATCNet-CIAM achieves 86.32% accuracy on BCI IV-2a and 87.96% on BCI IV-2b under the standard protocol, while reaching 89.46% and 83.64% in the within-session WBCIC-MI on 2C and 3C, respectively. The proposed framework consistently improves classification stability and robustness under session-varying conditions, and ablation study confirms the complementary contribution of the proposed architectural components.
Le Huu Son Hai, Nguyen Chi Hai, Truong Viet Vu +3
Jul 24, 2026cs.HC

Universal BCI Personalization: One API for Frozen EEG Trunks and Foundation Models

Frozen EEG encoders proliferate; per-model fine-tune defaults do not scale. We present Nimbus Personalizer: one contract encode to Bayesian head to BrainState (optional affine mid-tier) that sits on heterogeneous frozen trunks without a new personalization stack per architecture. Thesis (systems): the contribution is the trunk-agnostic API - not LDA-on-embeddings as an ML novelty - so OEMs integrate once and swap trunks. Evidence: the same surface runs on five classical trunks EEGNet, Shallow, Deep, Conformer, ATCNet x four MI datasets (18 cells) and on a foundation encoder (REVE) under the same Personalizer. Where embedding capacity exists, the head is a cheap default mid-point versus warm-start fine-tune or PEFT, costing orders of magnitude less adaptation wall time while recovering much of the fine-tune accuracy gain; calibration-only-when-clean holds in 12/18 cells. Head gains are supporting evidence that the API is useful where capacity exists. Subject-level confidence intervals identify the clearest dataset and span zero elsewhere. All results are exploratory (subject-level bootstrap, no confirmatory tests); the decision logic for when to escalate adaptation is addressed in our companion work on the control layer.
Sergey Musienko