cs.CVSep 12, 2026

TotalSynth: Robust Whole-Body Synthetic CT from MRI and CBCT

Authors: Valentin Boussot, Cedric Hemon, Anais Barateau, Caroline Lafond, Jean-Claude Nunes, Jean-Louis Dillenseger

Organizations: Univ. Rennes, CLCC Eugène Marquis, INSERM, LTSI - UMR 1099 F-35000 Rennes, France

Abstract

Purpose: To develop and evaluate TotalSynth, a reusable pretrained framework for whole-body synthetic CT (sCT) generation from MRI and cone-beam CT (CBCT) images. Materials and Methods: In this retrospective technical study, the dataset was assembled between 2020 and 2026 from SynthRAD challenge data, four prostate cohorts, and BIC-MAC. After registration quality control, 1450 of 1800 public challenge pairs were retained; 350 were excluded for insufficient registration quality or major source/CT mismatch. The corpus also included 84 additional prostate MRI/CT and 60 external BIC-MAC MRI/CT cases. Three 5-fold model families were evaluated with image-domain, anatomy-aware, registration-based, and uncertainty metrics. Age and sex were not consistently available across public datasets. Results: The released MRI-to-CT model achieved an overall MAE of 67.49 HU, SSIM of 0.920, and PSNR of 29.28 dB. The CBCT-to-CT model achieved an overall MAE of 53.55 HU, SSIM of 0.939, and PSNR of 32.09 dB. The unified model maintained similar performance on MRI inputs (MAE, 67.68 HU) and CBCT inputs (MAE, 54.22 HU). On external BIC-MAC data, MRI-to-CT MAE was 100.91 HU without fine-tuning and 62.21 HU after fine-tuning. Conclusion: TotalSynth provides reusable MRI- and CBCT-based CT synthesis models with broad anatomical coverage, while external evaluation highlights the need for local validation and optional fine-tuning under domain shift.

Figures & tables

Appendix figures & tables4 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

May 13, 2026

Generating synthetic computed tomography for radiotherapy: SynthRAD2025 challenge report

Radiation therapy (RT) requires precise dose delivery over multiple fractions, with CT fundamental for treatment planning due to its electron density information. Repeated CT acquisitions impose radiation exposure and logistical burdens, MRI lacks electron density, and cone-beam CT (CBCT) requires correction for dose calculation. Synthetic CT (sCT) generation addresses these by converting MRI or CBCT into CT-equivalent images with accurate Hounsfield Unit (HU) values, enabling MRI-only RT and CBCT-based adaptive workflows. Building on SynthRAD2023, SynthRAD2025 benchmarked sCT methods on 2,362 patients from five European centers across head and neck, thorax, and abdomen. Two tasks: MRI-to-CT (890 cases) and CBCT-to-CT (1,472 cases), evaluated via image similarity (MAE, PSNR, MS-SSIM), segmentation (Dice, HD95), and dosimetric metrics from photon and proton plans. With 803 participants and 12/13 valid submissions, Task 1 top performance reached MAE 64.8±21.364.8\pm21.3 HU, PSNR ∼\sim30 dB, MS-SSIM ∼\sim0.936, Dice 0.79, photon γ2%/2mm>98%γ_{2\%/2\text{mm}}>98\%, proton γ≈85%γ\approx85\%. Task 2 improved: MAE 48.3±13.448.3\pm13.4 HU, PSNR 32.6 dB, MS-SSIM 0.968, Dice 0.86, photon γ>99%γ>99\%, proton γ≈89%γ\approx89\%. Strong image--segmentation correlations (ρ=0.78ρ=0.78--0.790.79) but moderate dose correlations confirmed image quality is insufficient as a dosimetric surrogate. Head-and-neck cases were most consistent; thoracic and abdominal cases showed greater variability. Residual errors at tissue interfaces propagate along beam paths, affecting proton dose more than photon. SynthRAD2025 demonstrates that deep learning yields clinically relevant sCTs, especially for CBCT-to-CT, while identifying persistent MRI-to-CT challenges and underscoring dose-based evaluation as essential for clinical validation.
Apr 30, 2026

A Proof-of-Concept Study of Multitask Learning for Cranial Synthetic CT Generation Across Heterogeneous MRI Field Strengths

Accurate synthesis of computed tomography (CT) images from magnetic resonance imaging (MRI) is clinically valuable for cranial applications such as attenuation correction, radiotherapy planning, and image-guided interventions. However, heterogeneity across MRI field strengths and acquisition protocols limits the generalizability of existing methods. In this study, we formulate cranial CT synthesis as a modular, structurally coupled problem and propose a deep learning framework to improve robustness across heterogeneous MRI conditions. The model is designed to adapt to variations in field strength and imaging protocols while preserving anatomical consistency. Experiments on multi-site datasets demonstrate improved performance and generalization compared with conventional approaches. The proposed method enables reliable CT synthesis across heterogeneous MRI settings, supporting broader clinical translation.
Mar 30, 2026

MRI-to-CT synthesis using drifting models

Accurate MRI-to-CT synthesis could enable MR-only pelvic workflows by providing CT-like images with bone details while avoiding additional ionizing radiation. In this work, we investigate recently proposed drifting models for synthesizing pelvis CT images from MRI and benchmark them against convolutional neural networks (UNet, VAE), a generative adversarial network (WGAN-GP), a physics-inspired probabilistic model (PPFM), and diffusion-based methods (FastDDPM, DDIM, DDPM). Experiments are performed on two complementary datasets: Gold Atlas Male Pelvis and the SynthRAD2023 pelvis subset. Image fidelity and structural consistency are evaluated with SSIM, PSNR, and RMSE, complemented by qualitative assessment of anatomically critical regions such as cortical bone and pelvic soft-tissue interfaces. Across both datasets, the proposed drifting model achieves high SSIM and PSNR and low RMSE, surpassing strong diffusion baselines and conventional CNN-, VAE-, GAN-, and PPFM-based methods. Visual inspection shows sharper cortical bone edges, improved depiction of sacral and femoral head geometry, and reduced artifacts or over-smoothing, particularly at bone-air-soft tissue boundaries. Moreover, the drifting model attains these gains with one-step inference and inference times on the order of milliseconds, yielding a more favorable accuracy-efficiency trade-off than iterative diffusion sampling while remaining competitive in image quality. These findings suggest that drifting models are a promising direction for fast, high-quality pelvic synthetic CT generation from MRI and warrant further investigation for downstream applications such as MRI-only radiotherapy planning and PET/MR attenuation correction.