DTI-Guided Volumetric Spherical Harmonics Regression for Single-to-Multi-Shell dMRI Synthesis
Organizations: Juntendo University, Tokyo, Japan · RIKEN Center for Advanced Intelligence Project, Tokyo, Japan · Tokyo University of Agriculture and Technology, Tokyo, Japan
Abstract
Multi-shell diffusion MRI (dMRI) unlocks more expressive microstructural modeling than single-shell scans, yet its longer acquisition time hinders deployment in large-scale cohorts and time-constrained clinical settings. Synthesizing an unobserved shell from a single-shell input is fundamentally ill-posed and further complicated by protocol mismatch, where source and target gradient direction sets may not align. We propose DTI-SHNet, a single-to-multi-shell synthesis framework that operates in the real symmetric spherical harmonics (SH) coefficient domain and performs spatially aware volumetric regression. Given a source shell, we estimate diffusion tensor imaging (DTI) and use direction-agnostic parametric maps along with a brain mask as conditioning priors to guide a 3D U-Net regressor from source-shell to target-shell SH coefficients. To couple coefficient accuracy with signal fidelity, we introduce a signal consistency regularization that reconstructs signals on randomly sampled canonical directions from predicted coefficients and enforces agreement in the signal domain. Experiments on UK Biobank and Cam-CAN data for b=1000 to b=2000 dMRI synthesis show that DTI-SHNet achieves competitive visual quality compared to advanced methods, while better preserving downstream diffusion measures. Our code is available at https://github.com/xiaovhua/dti-shnet.
Figures & tables
| Method | UKB | Cam-CAN | ||||
| PSNR | SSIM | NMSE | PSNR | SSIM | NMSE | |
| Extrapolation [ 2 ] | ||||||
| DDPM [ 5 ] | ||||||
| SH-DNN [ 11 ] | ||||||
| DirUNet [ 4 ] | ||||||
| DTI-SHNet | ||||||
| Condition | UKB | Cam-CAN | |||||||||
| Priors | PSNR | SSIM | NMSE | FA | MD | PSNR | SSIM | NMSE | FA | MD | |
| 25.33 | 0.9218 | 0.0829 | 0.0235 | 0.337 | 27.90 | 0.9547 | 0.0341 | 0.0604 | 0.903 | ||
| 25.42 | 0.9235 | 0.0814 | 0.0224 | 0.322 | 28.64 | 0.9627 | 0.0288 | 0.0418 | 0.656 | ||
| 25.29 | 0.9219 | 0.0838 | 0.0233 | 0.282 | 28.61 | 0.9639 | 0.0290 | 0.0343 | 0.467 | ||
| 25.33 | 0.9216 | 0.0830 | 0.0220 | 0.281 | 29.32 | 0.9700 | 0.0246 | 0.0319 | 0.426 | ||
Medical Image Synthesis
Medical image synthesis creates, translates, reconstructs, and edits clinical images to fill missing data and support analysis.