eess.SYSep 15, 2026

Unified Heterogeneous Graph Neural Network solver for Power Flow, Optimal Power Flow and State Estimation

Authors: Ferran Bohigas-DaranasHamid Latif-MartínezEduardo Prieto-AraujoOriol Gomis-BellmuntPere Barlet-Ros

Abstract

Power Flow (PF), Optimal Power Flow (OPF), and State Estimation (SE) are fundamental problems in power system analysis, but solving them is computationally expensive. Graph Neural Networks (GNNs) have been proposed as fast surrogates, yet existing solvers are trained for a single problem at a time, producing narrow models that must be rebuilt for each new task. We propose a more general approach: a single Heterogeneous Residual Gated Graph Convolutional Network that solves all three problems with one shared backbone. Rather than learning one mapping, the model learns a reusable representation of how the network behaves, from which PF, OPF, and SE can each be estimated. Trained jointly on the three problems across diverse topologies and loading conditions, and evaluated on the IEEE 14-bus and 118-bus systems, the shared model matches the accuracy of task-specific GNN solvers and stays robust on unseen loading levels and topologies. These results show that a single model can capture the basic operation of a power network and serve several analysis tasks at once, a first step toward a foundation model for power systems.

Explore similar work

May 22, 2026cs.LG

Scalable Heterogeneous Graph Foundation Models for Data-Driven Optimal Power Flow in Smart Grids

Fast and reliable optimal power flow (OPF) approximation is essential for reliable smart-grid operation, yet many learning-based surrogates either flatten the native heterogeneous structure of power networks, target a limited set of grid topologies, or lack scalable infrastructure for graph foundation model (GFM) training. This paper presents a scalable heterogeneous graph neural network (GNN) workflow, built on HydraGNN, for data-driven OPF surrogate modeling and OPF-GFM development. The workflow preserves the distinct node and edge types of power grids -- buses, generators, loads, shunts, AC lines, transformers, and device-to-bus couplings -- and supports distributed preprocessing, training, hyperparameter optimization (HPO), and downstream fine-tuning on leadership-class supercomputers. Using three million heterogeneous graph instances spanning ten PGLib-OPF cases, from 14 to 13,659 buses, we conduct DeepHyper-driven HPO on the ORNL Frontier supercomputer. The campaign identifies compact models (\sim1.6--1.7M parameters) with the lowest validation losses. Downstream experiments on feasibility classification and N-1 contingency regression show that fine-tuning pretrained OPF GFM improves low-data accuracy, stabilizes training, accelerates convergence, and reduces adaptation cost when partial or head-only fine-tuning is used.
Massimiliano Lupo Pasini, Yijiang Li, Kibaek Kim +1
Aug 10, 2026cs.AI

GENCO - A Unified Neural Solver Embedded in a Development Framework for Steady-State Grid Analysis

Foundation models are transforming business workflows and boosting productivity, yet they remain largely absent from engineering domains such as power system analysis, where strict physical consistency must be enforced. We present GENCO (GEometric Neural Corrective Optimizer), a unified neural solver for steady-state transmission grid analysis that handles power flow (PF), optimal power flow (OPF), and state estimation (SE) within a single architecture and shared network representation. To support advances in neural power system solvers, we introduce the open-source GridFM Development Framework, which standardizes synthetic data generation and training in a low-code environment. We also release large-scale datasets with millions of PF and OPF scenarios across diverse grid topologies to support reproducible benchmarking. We evaluate GENCO on the PFDelta and OPFData benchmarks against state-of-the-art neural solvers and classical solvers, including Newton-Raphson and IPOPT, as well as on real-world Hydro-Québec SCADA data. For large-scale PF, GENCO recovers the full AC operating state, including voltage magnitudes and reactive power that DC-PF cannot provide, while matching DC-PF-level active power-balance residuals. It achieves up to 30x speedups over Newton-Raphson at only 2x the runtime of DC-PF. For OPF, it achieves up to 85x speedups over IPOPT while improving feasibility, optimality, and runtime over DC-OPF. For SE, GENCO is more robust than classical weighted least squares to noisy measurements and network parameter errors, and always returns a high-quality estimate even when weighted least squares fails to converge. Together, the unified architecture and development framework provide a new approach to large-scale steady-state grid analysis, lowering the barrier to entry for power system engineers and marking a step toward Grid Foundation Models.
Alban Puech, Matteo Mazzonelli, Tamara R. Govindasamy +19
Jul 15, 2026cs.LG

MxGPS: Multiplex Graph Transformers for a Power Grid Foundation Model

Single-task fine-tuning of graph neural networks (GNNs) for power grid problems exhibits a systematic failure mode: models that achieve the lowest in-distribution error degrade the most under topology shift. We term this topology overfitting: the tendency of task-specific gradient signals to encode relational structure particular to the training topologies rather than the underlying physics, causing models to fail on unseen grids despite strong in-distribution performance. To expose and address this failure mode, we introduce MxGPS (Multiplex GPS), a multiplex graph transformer that runs K task-specialised GPS branches over a shared node encoder, jointly trained on Static State Estimation (SSE) and AC Power Flow (PF) via a self-supervised pre-training and multi-task fine-tuning protocol, with a cross-branch attention module evaluated in ablation. The joint SSE+PF objective forces the shared encoder to simultaneously satisfy complementary gradient signals, preventing it from overfitting to topology-specific relational structure. Under a 3-fold sliding-window cross-validation spanning four unseen topologies (14-, 24-, 162-, and 300-bus), MxGPS attains 0% boundary violation rate (BVR) on all four zero-shot Power Flow topologies. Critically, models with substantially lower in-distribution PF error degrade by 190% to 1400% under topology shift, whereas MxGPS degrades by only 39%, an inversion that directly implicates topology overfitting as the failure mechanism rather than insufficient model capacity. With only 1.6M parameters (12x fewer than the GridFM reference baseline), MxGPS demonstrates that multi-task joint training is a principled and parameter-efficient mechanism for topology-agnostic generalisation in power grid foundation models.
Charilaos Papaioannou, Ioannis Tsantilas, Dimitris Giannakakos +9