cs.CLSep 16, 2026

Reporting Practice Matters: The Impact of Reference Choice on Chest X-ray Report Evaluation

Authors: Daniel P. JeongCharles Q. LiHossein HosseinyNitya M. BhallaFatma Uyar MorencyPradeep RavikumarZachary C. LiptonMichael Oberst

Abstract

Radiologists follow heterogeneous reporting practices. Two radiologists examining the same image and identifying the same clinical findings might nevertheless compose superficially distinct reports, varying in terminology, shorthand, formatting, and level of detail. These variations in reporting norms represent an under-appreciated obstacle in efforts to evaluate AI-based radiology report generation (RRG) models, where machine-generated reports are typically assessed based on their concordance with human-generated references. In this paper, we quantify the sensitivity of established evaluation metrics to variations in reporting practices, revealing impacts large enough to alter the rankings of models. We introduce a radiologist-informed taxonomy of variations in radiology reporting practice and a method (ReRef) that rewrites reference reports along the axes of our taxonomy while preserving clinical interpretation. For instance, when comparing the performance of nine RRG models on MIMIC-CXR using RadCliQ-v1, condensing the discussion of normal findings in the reference reports causes Libra to drop from first to second place while CheXOne rises from third to first. Our results suggest that many current metrics fail to decouple clinical interpretation from conformity to reporting practices and that choosing the ``right'' references that accurately reflect the desired reporting practices can be important in practice. To support future research, we release MIMIC-CXR-Ext-ReRef, a radiologist-validated dataset of 120 (original, alternative) reference report pairs derived from MIMIC-CXR.

Explore similar work

Jul 28, 2026eess.IV

Rethinking Clinical Relevance in Chest X-ray Machine Learning: How Evaluation References Define Performance

Chest X-ray (CXR) machine learning relies heavily on automated evaluation using reference standards that aim to approximate clinical judgment. However, commonly used report-derived labels for pathology classification or generic image quality metrics for reconstruction may not reliably reflect clinical judgment. We systematically investigate how evaluation-reference choices affect model performance and ranking in both pathology classification and image quality assessment (IQA). To enable controlled comparison across evaluation references, we collected paired expert image- and report-derived labels for thoracic findings from a clinical cohort at Cambridge University Hospitals (CUH) and curated a subset of the public MIMIC-CXR dataset, along with expert ratings of diagnostic image quality. We show that for supervised image classifiers (ResNet, DenseNet), several zero-shot and fine-tuned vision-language models (e.g., MedKLIP, GLoRIA, and ConVIRT), changing the label source leads to substantial differences not only in performance estimates but also in model rankings. In parallel, alignment of IQA measures with expert judgment depends heavily on the choice of measure, and commonly used IQA metrics such as SSIM and PSNR often fail to align with expert assessments of diagnostic usability. Our results demonstrate that evaluation choices are crucial: they can determine which models and methods appear best and are therefore selected for further development or deployment. The selection of evaluation references should therefore be treated as a central component of clinical validity in CXR machine learning, and justified with respect to the pathology, imaging task, and intended downstream clinical use.
Panagiotis Fytas, Ian Selby, Clemens Karner +14
Apr 21, 2026cs.CV

CXRMate-2: Structured Multimodal Temporal Embeddings and Tractable Reinforcement Learning for Clinically Acceptable Chest X-ray Radiology Report Generation

Chest X-ray (CXR) radiology report generation (RRG) models have shown rapid progress on automated metrics, yet their clinical utility remains uncertain due to limited qualitative evaluation by radiologists. We present CXRMate-2, a state-of-the-art CXR RRG model that enables tractable reinforcement learning (RL) through structured multimodal temporal embeddings and high-resolution visual feature compression, for efficient, unified conditioning of an LLM decoder on visual, textual, and temporal context from a study and its prior. This enables group relative policy optimisation (GRPO), where a proposed reward function is used to improve semantic alignment with radiologist reports. Across the MIMIC-CXR, CheXpert Plus, and ReXgradient datasets, CXRMate-2 achieves statistically significant improvements over strong benchmarks, including gains of 11.2% and 24.4% in GREEN and RadGraph-XL, respectively, on MIMIC-CXR relative to MedGemma 1.5 (4B). To directly compare CXRMate-2 against radiologist reporting, we conduct a blinded, randomised qualitative retrospective evaluation. Three consultant radiologists compare generated and radiologist reports across 120 studies from the MIMIC-CXR test set. Generated reports were deemed acceptable (defined as preferred or rated equally to radiologist reports) in 45% of ratings, with no statistically significant difference in preference rates for seven of the eight analysed findings. Preferences for radiologist reports were driven primarily by higher recall, while generated reports were consistently preferred for readability. Together, these results define a clear pathway to clinically acceptable CXR RRG. Improving recall and the detection of subtle findings represents the primary remaining barrier to non-inferiority with radiologist reporting, positioning CXR RRG for prospective evaluation in assistive, radiologist-led workflows.
Aaron Nicolson, Elizabeth J. Cooper, Hwan-Jin Yoon +7
Jun 13, 2026cs.CL

ReportQA: QA-Based Radiology Report Evaluation

Radiology report evaluation is essential for advancing automated report generation. Natural language generation metrics have limited clinical relevance. Clinical efficacy (CE) metrics evaluate important medical findings, but focus mainly on presence and cover only a limited set of entities. Due to heavy reliance on manual annotations, it is difficult for CE metrics to extend clinical entities or attributes. In clinical practice, radiology reports serve as a medium for information transfer. Clinicians use them to perform downstream diagnostic tasks without directly inspecting images. Based on this insight, we propose ReportQA, a clinical-related and flexible radiology report evaluation framework, supporting detailed quantitative analysis of radiology report generation systems. We first collect datasets covering multiple imaging modalities and anatomical regions. We then construct knowledge trees of clinical entities and attributes with radiologist guidance, and use large language models (LLMs) to extract structured information from raw reports. Next, we generate QA pairs from predefined templates and apply quality control through self-filtering and report-based filtering. During evaluation, the report is treated as context, and an LLM acts as a judge model to answer the QA pairs. Based on the resulting QA accuracy, we introduce QAScore metric. Compared with existing metrics, QAScore shows better alignment with radiologist judgments. Experiments on multiple state-of-the-art vision-language models reveal that current report-based inference paradigms struggle to learn fine-grained clinical representations and exhibit strong negative prior biases. In contrast, question-driven inference provides a more effective alternative. For reproducibility and extensibility, we release the knowledge trees, structured reports, and QA pairs, along with the pipeline code for QA construction and evaluation.
Yiming Shi, Shaoshuai Yang, Xi Chen +10