cs.ROSep 22, 2026

Digital Twin-Driven VR Teleoperation with Multi-View Spatial Perception for Surgical Robots

Authors: Chang LiuChenhao YuHonghao ZhaoHao DingHaochen WeiAdnan MunawarMathias UnberathPeter Kazanzides

Abstract

Current robot-assisted minimally-invasive surgery (RMIS) platforms provide a fixed console for the surgeon to view stereo endoscopic images and teleoperate instruments inside the patient. Several researchers have proposed the use of a head-mounted display (HMD) as a portable console, with video pass-through rendering of the endoscope images which, like the fixed console, restricts the operator to a single endoscopic viewpoint and limits depth perception. We present a digital twin-driven virtual reality (VR) teleoperation platform, where the digital twin is created from markerless perception of the surgical environment and streamed for display on the HMD. This overcomes the limitations of video pass-through by providing multi-view rendering and natural motion-parallax cues, enabling decoupling of the user's hand posture from strict instrument alignment. The system utilizes VR hand controllers to increase the teleoperation workspace and to improve the robustness and stability of instrument control compared to the hand tracking approach adopted by most prior systems. A 15-participant user study on the da Vinci Research Kit (dVRK) shows that our VR platform significantly outperforms a state-of-the-art HoloLens 2 mixed reality baseline, reducing path length by 86% and jerk by 95%, while achieving depth perception confidence comparable to or exceeding the traditional console across all conditions.

Explore similar work

May 27, 2026cs.RO

A Digital Twin Framework for Virtual Visuo-Haptic Teleoperation of Complex-Shaped Optical Microrobots

Optical tweezers (OT) provide piconewton-scale manipulation for delicate biomedical tasks, where visuo-haptic feedback can improve operator awareness by conveying interaction-force cues and trap-stability information. However, visuo-haptic teleoperation frameworks for complex-shaped optical microrobots remain underdeveloped, particularly in multi-trap manipulation scenarios. This paper presents a digital twin framework for virtual visuo-haptic teleoperation of complex-shaped OT-driven microrobots. The framework integrates a digital twin environment, image-based pose and depth estimation, microrobot motion simulation, and model-based haptic rendering within a Robot Operating System (ROS)-connected bimanual teleoperation system. For force modeling, we combine a Multi-Sphere Distributed Manipulation (MSDM) model with optical-force estimation from the Optical Tweezers Toolbox, enabling simulator-driven visuo-haptic feedback. The framework reproduces representative microrobot motion trends and provides haptic force rendering that is numerically consistent with the fitted optical-force model. In simulated cell-delivery tasks, haptic feedback reduced the standard deviations of the contact-force metric and the microrobot-to-trap-center distance metric by 53.2% and 55.2%, respectively, and improved task success from 30% to 80%. These results demonstrate the framework's effectiveness for evaluating visuo-haptic teleoperation strategies for complex-shaped optical microrobots.
Zongcai Tan, Lan Wei, Dandan Zhang
Aug 10, 2026cs.RO

Trajectory Divergence Horizon Decision for Reliable Dual-Arm Surgical Subtask Manipulation

Surgical robotic systems are increasingly being adopted as clinical workload rises, motivating autonomous solutions for repetitive manipulation subtasks. Learning-based controllers improve generalization compared with rule-based and analytic approaches, but most are trained for individual tasks and remain difficult to reuse across procedures. Vision-Language-Action (VLA) models provide a unified framework that integrates visual perception, language grounding, and action generation, offering a promising path toward more composable surgical autonomy. However, existing VLA policies rely on fixed-length open-loop action sequences, where changing scene conditions can lead to accumulated errors and potential risks in surgical manipulation. To mitigate this issue, we formulate surgical VLA deployment as an adaptive execution-horizon decision problem and propose Trajectory Divergence Horizon Decision (TDHD), a test-time mechanism that estimates step-wise action reliability by measuring the divergence between two flow-matching-generated trajectories under small noise perturbations and truncates execution using a dual-threshold rule to trigger timely replanning. We further establish a real-world da Vinci-like dual-arm benchmark with synchronized multi-view perception and language instructions, and collect 600 teleoperated demonstrations across needle (reach, pick, regrasp) and tissue (reach, lift, resection) manipulation suites. On real hardware with 20 trials per task setting, TDHD consistently improves performance over the latest VLA baselines: success increases from 55% to 60% for needle manipulation and from 55% to 80% for tissue manipulation, with the largest gains observed in the final manipulation stages. These results highlight the importance of adaptive execution control for reliable deployment of VLA models in surgical robotic manipulation.
Mingwu Su, Guankun Wang, Jinsong Lin +8
Jul 21, 2026cs.RO

MVP-Tac: A Miniaturized Dual-Modal Vision and Photoelastic Tactile Sensor for Robot-Assisted Minimally Invasive Surgery

Robot-assisted minimally invasive surgery (RMIS) offers major benefits over open and conventional laparoscopic procedures, yet it still lacks tactile feedback for palpation while operating under strict requirements to preserve reliable vision for navigation and safety. In practice, visual feedback is indispensable, and tactile solutions that cannot coexist with vision are difficult to translate into RMIS tools. To address both needs, we introduce MVP-Tac, a compact, vision-based tactile sensor that provides co-located vision and tactile sensing. MVP-Tac uses reflective photoelastic imaging: a thin photoelastic elastomer produces stress-dependent interferograms under contact that are captured by an embedded camera through a miniaturized reflective polariscope. A semi-transparent membrane and controllable illumination enable switching between visual mode and tactile mode, enabling tactile perception without sacrificing vision. We validate MVP-Tac through force calibration in the 0 to 2 N range and demonstrate its potential for tumor palpation via video-based hardness classification on tissue phantoms, achieving 97% accuracy for exposed-tumor classification and 92% accuracy for subdermal-tumor classification. Finally, we conduct a simulated colonoscopy to validate both visual and tactile modalities in a constrained lumen, including vision-guided 3D photomapping of the luminal wall and in situ hardness classification of localized nodules. Overall, MVP-Tac provides a practical path toward restoring clinically useful palpation in RMIS while maintaining essential visual feedback. The design, fabrication, and firmware of MVP-Tac are open-sourced at https://mvp-tac.github.io/
Md Rakibul Islam Prince, Jaeeun Kim, Yuhao Zhou +9