Evaluating ADC-only deep learning pipelines for breast cancer detection and segmentation using standalone diffusion-weighted MRI
Authors: Pablo García Marcos, Paula Puerta Gonzĺez, Guillermo Lorenzo, Héctor Gómez, Covadonga del Camino, Angel Rio-Alvarez, Víctor M. González
Organizations: Computer Sciences Department, University of Oviedo, Asturias, Spain · Biomedical Engineering Center (BME), University of Oviedo, Asturias, Spain · Electrical Engineering Department, University of Oviedo, Asturias, Spain · Group of Numerical Methods in Engineering, Department of Mathematics, University of A Coruña, A Coruña, Spain · Oden Institute for Computational Engineering and Sciences, The University of Texas at Austin, Austin, Texas, USA · School of Mechanical Engineering, Purdue University, West Lafayette, Indiana, USA · Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana, USA · Purdue Center for Cancer Research, Purdue University, West Lafayette, Indiana, USA · Radiodiagnostic Service. Asturias Central University Hospital (HUCA). Oviedo, Spain
Dynamic contrast-enhanced (DCE) imaging is the gold standard technique for the detection and characterization of breast cancer using magnetic resonance imaging (MRI). However, DCE-MRI requires long acquisition times and the administration of contrast into the bloodstream, which can cause allergic reactions. Alternatively, diffusion-weighted MRI (DW-MRI) is a standard complementary technique for breast MRI that does not require contrast, has shorter acquisition times, and enables calculation of apparent diffusion coefficient (ADC) maps that correlate with tumor cellularity. Yet, despite these technical advantages, deep learning research has focused on DCE-based models and has barely explored the tumor detection performance of DW-MRI and ADC maps either in combination with DCE-MRI or as standalone alternatives. Here, we evaluate the application of different state-of-the-art deep learning techniques for detection and segmentation of breast cancer using ADC-only images. This is, to our knowledge, the first comprehensive evaluation of ADC-only breast cancer pipelines for classification, detection, and segmentation tasks.
Figures & tables
Figure 1: Slice of a study of the dataset in DW (left), ADC (center) and mask (right) formats.
Fold
Precision
Recall
Accuracy
Specificity
1
0.945
0.896
0.933
0.960
2
0.958
0.865
0.921
0.969
3
0.954
0.823
0.910
0.971
4
0.916
0.813
0.881
0.938
5
0.939
0.826
0.905
0.962
Mean
0.942
0.844
0.910
0.960
Table 1: Performance of the model in slice classification.
Figure 2: Classification results: ADC slices correctly classified by the model.
Figure 3: Classification results: ADC slices incorrectly classified by the model.
Fold
Precision
Recall
AP
1
0.917
0.767
0.840
2
0.894
0.671
0.775
3
0.864
0.634
0.722
4
0.842
0.649
0.730
5
0.878
0.681
0.724
Mean
0.878
0.680
0.758
Table 2: Performance of the model in tumor detection and localization.
Model
DICE
2D
0.699
3D
0.696
Table 3: Performance in breast cancer tumor semantic segmentation.
Figure 4: Localization results: (a) The ground truth shows the tumor enclosed by a blue box and assigned the label 0. (b) The tumor is enclosed in a blue box labeled as class 0, with the confidence score (0.9) shown next to the label.
Figure 5: Localization results: (a) The ground truth shows the tumor enclosed by a blue box and assigned the label 0. (b) The model prediction shows two boxes with label 0, one with confidence score 0.9 (correct) and one with confidence score 0.6 (incorrect).
Dynamic contrast enhanced breast MRI (DCE-MRI) is a powerful clinical tool for breast cancer detection, providing high resolution anatomical detail together with rich temporal contrast information. However, high dimensional 4D inputs, small lesions, and heterogeneous acquisition protocols across clinical sites hinder robust automated classification of healthy, benign, and malignant cases. To address these challenges, we propose a framework that dynamically analyzes latent representations to adapt to protocol-specific characteristics. Spatial variability is mitigated by reducing confounding background uptake and compensating for misalignment caused by deformable soft tissue. Additionally, relationships in the latent space across phases are leveraged to select the most informative temporal features, improving robustness to protocol-specific temporal variability. Finally, task specific discriminative features are promoted through large scale supervised lesion segmentation pretraining, which substantially enhances downstream finetuning. Evaluated under leave-one-center-out validation on the ODELIA dataset and the held-out AMBL cohort, the proposed framework substantially outperforms finetuned radiology foundation models and prior methods, improving mean AUROC by nearly 8 points and balanced accuracy by 4 points over the strongest baseline. Additionally, our method achieved first place in the MICCAI ODELIA Breast MRI Challenge 2025, further demonstrating its effectiveness for robust breast cancer classification. We publicly release our codebase under https://github.com/MIC-DKFZ/CURIAtor.
Benjamin Hamm, Yannick Kirchhoff, Maximilian Rokuss +6
German Cancer Research Center (DKFZ) Heidelberg, Division of Medical Image Computing, Germany · Medical Faculty, Heidelberg University, Germany · Faculty of Mathematics and Computer Science, Heidelberg University, Germany +3
Diffusion-weighted imaging (DWI) can support lesion detection and characterization in breast magnetic resonance imaging (MRI), however especially high b-value diffusion-weighted acquisitions can be prone to intensity artifacts that can affect diagnostic image assessment. This study aims to detect both hyper- and hypointense artifacts on high b-value diffusion-weighted images (b=1500 s/mm2) using deep learning, employing either a binary classification (artifact presence) or a multiclass classification (artifact intensity) approach on a slice-wise dataset.This IRB-approved retrospective study used the single-center dataset comprising n=11806 slices from routine 3T breast MRI examinations performed between 2022 and mid-2023. Three convolutional neural network (CNN) architectures (DenseNet121, ResNet18, and SEResNet50) were trained for binary classification of hyper- and hypointense artifacts. The best performing model (DenseNet121) was applied to an independent holdout test set and was further trained separately for multiclass classification. Evaluation included area under receiver operating characteristic curve (AUROC), area under precision recall curve (AUPRC), precision, and recall, as well as analysis of predicted bounding box positions, derived from the network Grad-CAM heatmaps. DenseNet121 achieved AUROCs of 0.92 and 0.94 for hyper- and hypointense artifact detection, respectively, and weighted AUROCs of 0.85 and 0.88 for multiclass classification on single-slice high b-value diffusion-weighted images. A radiologist evaluated bounding box precision on a 1-5 Likert-like scale across 200 slices, achieving mean scores of 3.33+-1.04 for hyperintense artifacts and 2.62+-0.81 for hypointense artifacts. Hyper- and hypointense artifact detection in slice-wise breast DWI MRI dataset (b=1500 s/mm2) using CNNs particularly DenseNet121, seems promising and requires further validation.
Ameya Markale, Luise Brock, Ihor Horishnyi +10
Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Maximiliansplatz 3, 91054 Erlangen, Germany · Institute of Computer Science, Polish Academy of Science, Warsaw, Poland · Department of Artificial Intelligence in Biomedical Engineering (AIBE), Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany +2
Dynamic contrast-enhanced breast MRI (DCE-MRI) is rich in anatomical and perfusion information, but its reliance on gadolinium-based contrast agents raises safety concerns and adds cost. Virtual contrast enhancement, synthesizing post-contrast from pre-contrast images, is a promising alternative. We address the MAMA-SYNTH challenge task of predicting peak-enhancement breast MRI. Rather than adopting the full machinery of diffusion or flow matching, we observe that under a rectified, straight-line path the generative process collapses to a single difference prediction: the synthetic peak image is the pre-contrast image plus a predicted enhancement map, recovered in one forward pass. Around this we build Anguinus Sculpturae, a compositional pipeline in which nnU-Net segmentations of lesion, foreground and breast region guide two generators - one optimized for global fidelity, one for lesion structure through an asymmetric Tversky term routed via a frozen segmenter - composited region-wise with Gaussian-weighted blending. On the held-out Duke subset of MAMA-MIA our model achieves the best FRD and Dice among all evaluated variants, showing that single-step difference prediction with segmentation guidance suffices to recover both global fidelity and lesion structure. Code is available at https://github.com/MIC-DKFZ/AnguinusSculpturae.
Benjamin Hamm, Nico Albert Disch, Maximilian Rokuss +3
German Cancer Research Center (DKFZ) Heidelberg, Division of Medical Image Computing, Germany · Medical Faculty, Heidelberg University, Germany · Faculty of Mathematics and Computer Science, Heidelberg University, Germany +3