cs.CVMar 4, 2026

Slice-wise quality assessment of high b-value breast DWI via deep learning-based artifact detection

Authors: Ameya Markale, Luise Brock, Ihor Horishnyi, Dominika Skwierawska, Tri-Thien Nguyen, Hannes Schreiter, Shirin Heidarikahkesh, Lorenz A. Kapsner, +5 more

Organizations: Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Maximiliansplatz 3, 91054 Erlangen, Germany · Institute of Computer Science, Polish Academy of Science, Warsaw, Poland · Department of Artificial Intelligence in Biomedical Engineering (AIBE), Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany · Pattern Recognition Lab, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany · Medical Informatics, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany

Abstract

Diffusion-weighted imaging (DWI) can support lesion detection and characterization in breast magnetic resonance imaging (MRI), however especially high b-value diffusion-weighted acquisitions can be prone to intensity artifacts that can affect diagnostic image assessment. This study aims to detect both hyper- and hypointense artifacts on high b-value diffusion-weighted images (b=1500 s/mm2) using deep learning, employing either a binary classification (artifact presence) or a multiclass classification (artifact intensity) approach on a slice-wise dataset.This IRB-approved retrospective study used the single-center dataset comprising n=11806 slices from routine 3T breast MRI examinations performed between 2022 and mid-2023. Three convolutional neural network (CNN) architectures (DenseNet121, ResNet18, and SEResNet50) were trained for binary classification of hyper- and hypointense artifacts. The best performing model (DenseNet121) was applied to an independent holdout test set and was further trained separately for multiclass classification. Evaluation included area under receiver operating characteristic curve (AUROC), area under precision recall curve (AUPRC), precision, and recall, as well as analysis of predicted bounding box positions, derived from the network Grad-CAM heatmaps. DenseNet121 achieved AUROCs of 0.92 and 0.94 for hyper- and hypointense artifact detection, respectively, and weighted AUROCs of 0.85 and 0.88 for multiclass classification on single-slice high b-value diffusion-weighted images. A radiologist evaluated bounding box precision on a 1-5 Likert-like scale across 200 slices, achieving mean scores of 3.33+-1.04 for hyperintense artifacts and 2.62+-0.81 for hypointense artifacts. Hyper- and hypointense artifact detection in slice-wise breast DWI MRI dataset (b=1500 s/mm2) using CNNs particularly DenseNet121, seems promising and requires further validation.

Figures & tables

Explore similar work

Aug 18, 2026

Evaluating ADC-only deep learning pipelines for breast cancer detection and segmentation using standalone diffusion-weighted MRI

Dynamic contrast-enhanced (DCE) imaging is the gold standard technique for the detection and characterization of breast cancer using magnetic resonance imaging (MRI). However, DCE-MRI requires long acquisition times and the administration of contrast into the bloodstream, which can cause allergic reactions. Alternatively, diffusion-weighted MRI (DW-MRI) is a standard complementary technique for breast MRI that does not require contrast, has shorter acquisition times, and enables calculation of apparent diffusion coefficient (ADC) maps that correlate with tumor cellularity. Yet, despite these technical advantages, deep learning research has focused on DCE-based models and has barely explored the tumor detection performance of DW-MRI and ADC maps either in combination with DCE-MRI or as standalone alternatives. Here, we evaluate the application of different state-of-the-art deep learning techniques for detection and segmentation of breast cancer using ADC-only images. This is, to our knowledge, the first comprehensive evaluation of ADC-only breast cancer pipelines for classification, detection, and segmentation tasks.
May 15, 2026

Layer Selection in Feature-Based Losses Affects Image Quality and Microstructural Consistency in Deep Learning Super-Resolution of Brain Diffusion MRI

Clinical application of high-resolution diffusion MRI is hindered by hardware limitations and prohibitive scan times, motivating computational super-resolution. This study investigates the efficacy of a feature-based loss function in preserving diffusion signal consistency in deep learning super-resolution. Using 7T data from the human connectome project to generate pairs of low- and high-resolution diffusion weighted images (DWI), we trained UNets for 2D super-resolution. Ablation and isolation studies evaluated different VGG16-layers for feature-based losses against an image-based L1 baseline. Deeper layers and combinations thereof resulted in grid-like artifacts in super-resolution DWIs, which persisted in diffusion parameters like quantitative and fractional anisotropy. No such artifacts were present when using the shallowest layer. Downstream analysis for this layer showed great consistency with the ground truth, even for 9-fold super-resolution. Image SNR and used VGG16-layer depths modulated artifact appearance and severity, mandating careful selection of contributing layers for application in and beyond diffusion MRI.
Mar 5, 2026

Interpretable Motion Artificat Detection in structural Brain MRI

Automated quality assessment of structural brain MRI is an important prerequisite for reliable neuroimaging analysis, but yet remains challenging due to motion artifacts and poor generalization across acquisition sites. Existing approaches based on image quality metrics (IQMs) or deep learning either requires extensive preprocessing, which incurs high computational cost, or poor generalization to unseen data. In this work, we propose a lightweight and interpretable framework for detecting motion related artifacts in T1 weighted brain MRI by extending the Discriminative Histogram of Gradient Magnitude (DHoGM) to a three dimensional space. The proposed method integrates complementary slice-level (2D) and volume-level (3D) DHoGM features through a parallel decision strategy, capturing both localized and global motion-induced degradation. Volumetric analysis is performed using overlapping 3D cuboids to achieve comprehensive spatial coverage while maintaining computational efficiency. A simple threshold-based classifier and a low parameter multilayer perceptron are used, which results in a model with only 209 trainable parameters. Our method was evaluated on the MR-ART and ABIDE datasets under both seen-site and unseen-site conditions. Experimental results demonstrate strong performance, achieving up to 94.34% accuracy the in domain evaluation and 89% accuracy on unseen sites, while almost completely avoiding false acceptance of poor-quality scans. Ablation studies confirms the complementary benefits of combining 2D and 3D features. Overall, the proposed approach offers an effective, efficient, and robust solution for automated MRI quality check, with strong potential for integration into large scale clinical and research workflows.