REMEDY: How Far Is Video Generation from Medical Education World Models?
Organizations: Beihang University · Beijing Institute of Technology · Beijing Information Science and Technology University
Abstract
Recent video generation models produce realistic videos and show potential as a foundation for world models. These advances create opportunities for generating medical teaching demonstrations, which requires both convincing visual quality and precise procedural actions. However, whether current generators can meet these requirements has not been measured. To address this problem, we introduce Readiness Evaluation of Medical Education Demonstration sYnthesis (REMEDY), to our knowledge, the first benchmark for AI-generated medical teaching demonstrations. REMEDY provides 900 first frames from real demonstration videos, covering 12 tasks across four scenarios: operating room, imaging, clinic and bedside, and resuscitation. Five contemporary open-source video generation models produce 4,500 videos from these frames. We combine task-specific clinical checklists with video and motion quality metrics. Evaluation covers four dimensions: clinical action following, clinical profiles, video quality, and motion quality. Our results show that realistic appearance and temporal consistency do not ensure correct clinical actions. Even the most advanced MiniMax-H3 achieves only 28.25% on strict clinical success rate, and fine-grained clinical actions remain challenging. These findings establish a foundation and roadmap for developing future medical education world models.
Figures & tables
| Clinical data | Evaluation dimensions | |||||||
| Benchmark | Task | Medical tasks | Real clinical frames | Performer in frame | Clinical action following | Clinical profiles | Video quality | Motion quality |
| VBench ( Huang et al., 2024 ) | T2V | – | – | – | – | – | – | |
| Video-Bench ( Han et al., 2025 ) | T2V | – | – | – | – | – | – | |
| UI2V-Bench ( Zhang et al., 2025 ) | I2V | – | – | – | – | – | ||
| HumanScore ( Fang et al., 2026 ) | T2V | – | – | – | – | |||
| EduVQA ( Chen et al., 2026a ) | T2V | – | – | – | – | – | ||
| Dimension | Metric | Evaluation focus |
|---|---|---|
| Clinical action following | Strict clinical success | Whether every task-essential atom passes with no critical failure. |
| Clinical Atom Score (CAS) | Mean value of the task’s atoms on 0-100. | |
| Clinical profiles | Clinical technique (1-5) | Correctness of the visible technique for the requested procedure. |
| Biomechanics (1-5) | Physical plausibility of body motion and clinician-patient contact. | |
| Professionalism (1-5) | Professional conduct, including step order and asepsis where required. | |
| Instruction following (1-5) | Adherence to the prompt’s action and camera instructions. |
| Strict clinical success (%) | ||||||||||||
| Model | PKA | TKA | MISS | US | Inj. | Exam | Wound | Dent. | IV | Sut. | CPR | Air |
| MiniMax-H3-FL2VA | 25.07 | 6.00 | 13.00 | 9.52 | 16.00 | 74.00 | 68.00 | 62.50 | 50.00 | 6.67 | 15.00 | 40.00 |
| Wan2.2-TI2V-5B | 21.97 | 2.00 | 5.05 | 13.10 | 12.00 | 44.00 | 34.00 | 17.50 | 7.50 | 0.00 | 5.00 | 16.67 |
| LTX-2.5 | 12.11 | 6.00 | 10.00 | 4.71 | 6.00 | 50.00 | 16.00 | 15.00 | 2.50 | 0.00 | 0.00 | 33.33 |
| LTX-2.3v | 0.85 | 0.00 | 0.00 | 14.29 | 4.00 | 36.00 | 6.00 | 2.50 | 2.50 | 3.45 | 0.00 | 6.67 |
| LTX-Video-2B | 1.41 | 0.00 | 0.00 | 3.53 | 4.00 | 34.00 | 6.00 | 10.00 | 0.00 | 0.00 | 0.00 | 3.33 |
| MiniMax-H3 | Wan2.2-5B | LTX-2.5 | LTX-2.3 | LTX-2B | |
| Ranking score (1-5) | 4.58 | 3.29 | 2.50 | 2.63 | 1.75 |
Appendix figures & tables8 assets
Supplementary material from the paper’s appendix.
Appendix
| Question | Required evidence |
|---|---|
| Is the requested procedure visibly performed with task-relevant motion, rather than only a pose, hand jitter, or unrelated movement? | Cite separated labelled frames showing the task begins and continues or reaches a later state. Hidden or omitted action is FAIL. |
| Does the camera remain locked off, without viewpoint motion, zoom, reframing, or crop drift beyond negligible encoding jitter? | Compare stable background landmarks near the beginning, middle, and end. |
| Are the visible people, anatomy, clothing, equipment, layout, framing, and scale preserved from the conditioning frame? | Compare the conditioning frame with labelled generated frames and name material drift. |
| Task | Task-specific question |
|---|---|
| Partial knee arthroplasty | Are visible instruments handled deliberately without implausible detachment or penetration? |
| Total knee arthroplasty | Does visible team activity sustain or advance the ongoing procedure? |
| Minimally invasive spine surgery | Is visible imaging or spine equipment positioned and handled in a controlled way? |
| Ultrasound | Does the transducer maintain continuous plausible contact with the intended body surface? |
| Injection | Does the visible sequence progress through a coherent injection action? |
| Physical examination | Are deliberate examination maneuvers visibly performed rather than a static touch? |
| Metric | Features and aggregation |
|---|---|
| Visual aesthetics | LAION aesthetic head ( Schuhmann and others, 2022 ; Huang et al., 2024 ) over CLIP ViT-L/14 features ( Radford and others, 2021 ) ; 32 uniformly sampled frames. |
| Subject consistency | DINO ViT-B/16 features ( Caron and others, 2021 ) ; 32 uniformly sampled frames. |
| Background consistency | CLIP ViT-B/32 features; 32 uniformly sampled frames. |
| Technical continuity | Full-clip penalties for black frames, repetition, freezes, and flashes. |
| PoseAct | YOLO11m-Pose body tracks ( Jocher and Qiu, 2024 ) ; smoothed, torso-normalized trajectories, joint angles, velocities, and motion energy compared with the real reference. Average valid pairs within tasks, then equally across twelve tasks. |
| PoseCov | Task-balanced fraction of valid generated/reference track pairs; failed tracks are not imputed. |
| Comparison | Strict Clinical Success Disagreements | Clinical Technique | Biomechanics | Professionalism | Instruction Following |
|---|---|---|---|---|---|
| Inter-Human | 0 | 0.907 | 0.921 | 1.121 | 1.501 |
| GPT-4o vs. Human | 2 | 1.217 | 1.705 | 1.600 | 1.035 |
| GPT-4o vs. Qwen-32B | 4 | 1.317 | 1.045 | 1.340 | 1.515 |
| GPT-4o vs. Gemini | 1 | 1.402 | 1.410 | 1.595 | 1.627 |
| Judge | Strict Clinical Success (%) | CAS | Clinical Technique | Biomechanics | Professionalism |
|---|---|---|---|---|---|
| GPT-4o | 93.33 | 94.79 | 4.79 | 4.63 | 4.86 |
| Qwen3-VL-32B | 85.00 | 88.75 | 4.38 | 4.33 | 4.40 |