cs.ROSep 27, 2026

Surgical Master Console Using General-Purpose Robot Arms and a Separable Articulated Distal Interface: Porcine In-Vivo Evaluation

Authors: Minsung Kim, Seonho Shim, Dongho Yee, Younghoon Noh, Juahn Oh, Yechan Seo, Jinseok Lee, Jiyul Lee, +4 more

Organizations: Department of Transdisciplinary Medicine, Seoul National University Hospital, Seoul, Republic of Korea. · Rosota Inc., Seoul, Republic of Korea. · Department of Mechanical Engineering, Seoul National University, Seoul, Republic of Korea. · Department of Mechanical Engineering, Chungang University, Seoul, Republic of Korea. · Department of Computer Science and Engineering, Seoul National University, Seoul, Republic of Korea. · Eulji University College of Medicine, Daejeon, Republic of Korea. · Department of Medicine, Seoul National University College of Medicine, Seoul, Republic of Korea. · Interdisciplinary Program in Medical Informatics, Seoul National University College of Medicine. · Institute of Convergence Medicine with Innovative Technology, Seoul National University Hospital, Seoul, Republic of Korea.

Abstract

High-performance surgical master consoles offer intuitive articulated manipulation but are expensive and difficult to reproduce, while accessible commercial haptic devices lack built-in interfaces for surgical wrist articulation and continuous grasp. We present a laparoscopic master in which general-purpose robot manipulators provide the programmable base and surgical-specific interaction is concentrated in a separable distal adapter. Each 6-DoF arm carries a custom 2-DoF direct-drive wrist, continuous grasp sensing, and clutch-based workspace management; the complete bimanual hardware costs approximately US$5,500, below common bimanual commercial haptic references. To support sustained hand-guided use, we characterize current scaling, gravity, and break-away friction and use them for posture-dependent gravity compensation and motion-gated assistance, reducing continuous actuation and thermal loading. A common master state drives either Isaac Sim or an RCM-constrained dual-FR3 platform. Master-state publication to FR3 target update adds at most 8 ms, and tip tracking shows 0.31-0.66 mm mean delay-aligned residuals. In a porcine cholecystectomy experiment, five common operator-side metrics and hand/tip-speed distributions were compared descriptively with human in-vivo telemetry from 120 clinical Versius recordings of 99 cholecystectomy procedures; no interruption originated from the master console, and no abnormal clinical signs were recorded during the 7-day postoperative observation period. These results demonstrate a surgical master built from general-purpose robot arms with surgical-specific interaction concentrated in a separable distal interface.

Figures & tables

Explore similar work

CardsList
  1. DASH: A da Vinci Adapter for Serial-link and Humanoid Robots as an Accessible Platform for Surgical Robotics Research

    Oct 5, 2026Sara Wickenhiser, Junrong Zhou, Zekai Liang +2Surgical Robotics

  2. A Controlled Comparison of Manual and Teleoperated Intraocular Instrument Motion for an Input Device

    Sep 8, 2026Korab Hoxha, Mirza Imamovic, Angelo Henriques +1Robot TeleoperationSurgical Robotics

  3. In vivo feasibility study of humanoid robots in surgery

    Jul 8, 2026Zekai Liang, Nikita Thareja, Peihan Zhang +7Robot TeleoperationSurgical Robotics