physics.med-phSep 30, 2026

An Uncertainty-Guided Digital Twin Framework for Online Adaptive Proton Therapy in Head and Neck Cancer: A Feasibility Study

Authors: Yizhou Wu, Ryan J. Sanford, Huiqiao Xie, Jie Ding, Shupeng Chen, Tung-Ho Wu, Ping-Hsiu Wu, Justin Roper, +7 more

Organizations: Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30308, USA · Department of Radiation Oncology, Taipei Medical University Hospital, Taipei, 110301, Taiwan · Department of Human Oncology, University of Wisconsin, Madison, WI 53792, USA · Department of Radiation and Cellular Oncology, University of Chicago, Chicago, IL 60637, USA

Abstract

Objective: Head and neck (HN) proton therapy spans six to seven weeks of anatomical change, while offline replanning takes about a week. We present an uncertainty-guided digital twin (UGDT) framework that forecasts treatment-day anatomy before treatment and evaluate whether it generates online adaptive proton therapy (APT) plans of clinical quality. Approach: A library of 302 longitudinal deformations from 88 previously treated HN patients was transported onto each new patient's treatment planning CT (TPCT) using two-step multi-atlas deformable image registration (DIR) built on a pretrained CT foundation model, generating about 284 predicted CTs (pdCTs) with contours per patient. Dispersion of propagated clinical target volume (CTV) contours defined a patient-specific robust margin. In ten patients, the quality assurance CT (QACT) triggering a replan represented treatment-day anatomy, and the physician-approved replan was the baseline. The pdCT most similar to the QACT (pdCT-H) and one from the lowest quartile (pdCT-L) were planned to within about 5% of baseline plan quality, forward-calculated on the QACT, and reoptimized to generate online APT plans. Main results: pdCT plans scored within -0.7% (pdCT-H) and -1.0% (pdCT-L) of baseline. Forward calculation on QACT reduced high-dose CTV D98% to 88.3% and 85.5%. After online reoptimization, D98% recovered to 98.3 +/- 0.3% and 98.2 +/- 0.3%, versus 98.5 +/- 0.4% at baseline. Spinal cord and brainstem doses remained below tolerance, and plan quality scores were within -1.1% (p = 0.19) and -1.7% (p = 0.01) of baseline. Significance: UGDT generated online APT plans comparable in quality to physician-approved offline replans using anatomy forecast before treatment, enabling a transition from reactive offline replanning toward anticipatory online adaptation.

Explore similar work

Aug 1, 2026physics.med-ph

Anticipatory Digital Twins for Online Head-and-Neck Adaptive Proton Therapy via Foundation-Model Registration

Head-and-neck (HN) proton therapy is highly sensitive to anatomical change over a 4-to-6-week course, as tumor shrinkage, weight loss, and setup variation can misposition the Bragg peak near critical organs such as the parotids, oral cavity, brainstem, and spinal cord, leading to target underdosing or organ-at-risk overdosing. Online adaptive proton therapy replans on the anatomy of the day, yet standard workflows rely on offline replanning that requires repeated CT acquisition and roughly a week of preparation, adding burden, cost, and delay. We investigate whether a patient's treatment-day anatomy can be predicted before image acquisition by transferring longitudinal change from a population database. We propose a digital-twin framework built on a pretrained foundation-model deformable registration network used without patient-specific training. A first registration aligns a prior patient's planning CT to the target and carries the prior's during-treatment quality assurance CT (QACT) into the target frame; a second registration estimates the prior's planning-to-QACT change, which is then applied to the target's own planning CT to synthesize predicted CTs (pdCTs) with propagated contours. Using 88 HN patients, each with a planning CT and three QACTs, we show that pdCTs better match treatment-day anatomy than the static planning CT. Compared with the planning CT alone, normalized cross-correlation improves by 22.8%, Dice for organs-at-risk by 20.2%, and CT-number error decreases by 23.4%. Gains are largest for patients with major anatomical change and negligible when anatomy is stable. This cross-patient motion transfer leverages the digital-twin concept to anticipate treatment-day anatomy, enabling personalized online adaptive proton therapy without repeated imaging.
Jul 15, 2026cs.LG

AI-Augmented Adaptive Digital Twin Modeling for Brain Tumor Evolution Prediction and Treatment Scheduling

Brain tumor progression exhibits spatially heterogeneous growth, patient-specific treatment response, and complex interactions with surrounding anatomy, making accurate long-term prediction challenging. We propose an AI-augmented adaptive digital twin (DT) framework for brain tumor evolution prediction and treatment scheduling. The framework integrates an interpretable reaction--diffusion (RD) model, a 3D residual learning module for model-form correction, patient-specific DT updating during recursive rollout, and model predictive control (MPC) for constrained chemotherapy and radiotherapy scheduling. Experiments on 387 synthetic tumor trajectories with 120-step evolution show that the baseline RD model captures tumor location and overall temporal behavior but underestimates heterogeneous tumor burden during long-horizon prediction. Hybrid RD--residual modeling reduces masked voxel-wise mean squared error by 84.3% and increases Dice overlap by 43.5% relative to the RD baseline under dense simulated observations. Online DT updating further reduces mean squared error by 45.9% and improves Dice overlap by 9.6% compared with the non-updated hybrid model. In MPC-based scheduling simulations, the updated DT controller reduces final tumor burden by 22.4% relative to a fixed treatment schedule under the terminal-burden objective. Together, these results demonstrate a unified framework for patient-specific initialization, mechanistic modeling, adaptive learning, and constrained treatment optimization. Although validated using patient-data-informed synthetic trajectories rather than clinical longitudinal data, the proposed framework establishes a foundation for future translation to real-world adaptive treatment planning.
Sep 8, 2026cs.CV

SynthRCT: Scalable Conditional Deformation Synthesis for Synthetic Repeat CT Generation

In proton therapy, plans are typically optimized on a single planning CT, making robustness evaluation essential under anatomical changes. However, current scenarios often rely on simplified perturbations that poorly capture complex, patient-specific variability. We propose SynthRCT, a scalable conditional generative framework for 3D anatomical deformation synthesis. Based on a conditional variational autoencoder, SynthRCT learns a latent deformation space and decodes sampled latent codes into local stationary velocity fields conditioned on an input anatomy. Local fields are assembled into coherent full-volume transformations, enabling memory-scalable generation for large field-of-view CT data. We validate the approach on respiratory 4DCT data with multiple breathing-phase anatomies per subject. SynthRCT enables patient-specific sampling of plausible anatomical transformations beyond predefined robustness scenarios. Code available at: https://github.com/TomasGuija/SynthRCT.