cs.CVSep 30, 2026

Scores That Hold, Benchmarks That Leak: Measuring Dataset Contamination in Public Brain-Tumor MRI Classification

Authors: Bhanu Prakash Vangala, Sowmya Guda, Latha Peddi, Navya Vangala

Organizations: Department of Electrical Engineering and Computer Science, University of Missouri, Columbia, MO 65211 USA · Government Degree College (Autonomous), Siddipet, Telangana 502103, India · Amar Biotech Private Limited, Kondapur, Hyderabad, Telangana 500084, India

Abstract

Automated classification of brain tumors from MRI is a heavily published application of deep learning in medical imaging, with reported accuracies on public benchmarks routinely exceeding 98%. However, accuracy does not capture a critical dimension of benchmark quality: dataset integrity, defined as the independence of test from training data at the image, patient, and acquisition-source levels. We introduce a three-layer contamination framework comprising duplicate, patient, and source-label leakage to assess the public corpora on which this literature rests. We audit the three most widely used corpora against a chest-radiograph negative control and quantify each layer's effect on measured performance across nine architectures and three evaluation conditions. Contamination is severe at every layer: 28.8% of the dominant corpus's official test split has a near-twin in its own training split, a second corpus leaks 22.3% of its test images byte-identically, 95.5% of traceable test images share a patient with training, and file-header features containing no anatomy separate tumor from no-tumor at 0.959 balanced accuracy, at parity with fine-tuned ResNet backbones. The unexpected result is that removing every identified leaked test image leaves balanced accuracy essentially unchanged: stable performance after deduplication does not establish benchmark integrity. Our findings establish dataset integrity as a distinct, measurable axis of benchmark quality that a stable leaderboard cannot certify. For biomedical research, reported accuracy on these corpora alone does not establish that a model has learned to recognize tumors rather than exploit dataset-specific cues. We release the contaminated-file lists, recovered patient identifiers, and deduplicated splits.

Figures & tables

Explore similar work

Jul 21, 2026cs.CV

Cross-Dataset Generalization in Breast MRI Tumor Classification via Class-Wise Dataset Mixing

Breast MRI is highly sensitive for detecting breast tumors, but exams contain many slices and require substantial reading time. Deep learning models often perform well on internal splits but can fail across institutions because of domain shift and dataset-origin bias. We study this failure mode for binary breast MRI tumor classification. EfficientNet-B3 and WaveViT-Small are trained using Duke Breast Cancer MRI and fastMRI, and evaluated only on the independent multi-center MAMA-MIA cohort. In a deliberately confounded setup, where label is perfectly correlated with dataset origin, external accuracy is near chance (0.5048--0.5265), despite very high recall. We then construct a mixed training set in which each class contains samples from both Duke and fastMRI, while preserving patient-level splitting, augmentation, and leakage controls. On MAMA-MIA, dataset mixing improves accuracy/F1 to 0.8463/0.8625 for WaveViT-Small and 0.8884/0.8994 for EfficientNet-B3. These results show that controlling dataset-origin bias is important for reliable breast MRI classification.
Jul 14, 2026cs.CV

Auditing Data Leakage in Whole-Slide Image Multimodal Benchmarks

Recent vision-language models (VLMs) for computational pathology report striking zero-shot performance on whole-slide image (WSI) visual question answering (VQA) benchmarks. We audit these claims and find them fundamentally compromised by data leakage at two hierarchical levels: patient-level leakage, where slides from the same case appear in both training and test folds, and institutional-level leakage, where different cases nonetheless share staining-batch and scanner signatures through a common Tissue Source Site (TSS). By tracing canonical slide, case, and TSS identifiers across major public resources, we document case level train test overlaps of 92.3~100% on TCGA-derived benchmarks, together with near-complete TSS overlap. We further demonstrate that both leakage levels are linearly decodable from foundation-model feature space, that they induce a measurable accuracy gap between leaked and audit-clean cases on a published checkpoint, and that across multiple published WSI VLMs, peak reported accuracies concentrate on the most heavily contaminated benchmarks. Therefore, the current WSI VQA evaluation cannot distinguish genuine multimodal reasoning from nearest-neighbor retrieval over memorized institutional and patient-specific artifacts. Finally, we outline concrete recommendations for contamination-free evaluation. By addressing benchmark construction, provenance disclosure, and automated overlap auditing, we aim to guide future research toward verifiable claims of progress.
Jun 23, 2026eess.IV

A Leakage-Aware Comparative Benchmark of Machine Learning, Deep Learning, and Transformer Models for Reliable Leukemia Detection

Automated classification of acute lymphoblastic leukemia (ALL) from peripheral blood smear images has often reported near-perfect performance on the C-NMC 2019 dataset. We show that such results can be inflated by patient-level data leakage caused by random image-level partitioning, where cells from the same subject may appear in both training and test folds. We establish a leakage-aware benchmark under a strict subject-disjoint protocol, comparing LightGBM, RBF-SVM, EfficientNet-B0, EfficientNet-B1, and ViT-Tiny. Models are developed using three subject-disjoint folds from 73 subjects and evaluated on an external preliminary-phase test set of 1,867 images from 28 unseen subjects with zero patient overlap. Beyond discrimination, we assess calibration using expected calibration error, Brier score, and temperature scaling. Under honest evaluation, EfficientNet-B1 achieves the best performance, with AUROC 0.913, sensitivity 0.87, specificity 0.80, and calibrated ECE 0.024. Frozen-feature classifiers and ViT-Tiny show high sensitivity but poor specificity, indicating a tendency to over-predict the malignant class. A random-versus-subject-disjoint ablation shows that random splitting inflates AUROC by about 0.04 even in the conservative frozen-feature setting. These findings caution against image-level evaluation on C-NMC 2019 and provide a reproducible, calibration-aware benchmark for future work.