cs.CVOct 6, 2026

One-Slide Calibration of Pathology Foundation Models

Authors: Ming Ren Hou, Tianyi Huang

Organizations: App-In Club · Ryquo

Abstract

Scanner variation changes how pathology foundation models represent the same tissue. We introduce SlideRuler, which uses regions within a slide as internal controls to estimate and correct acquisition-induced shifts in other regions. A transfer map learned from paired rescans enables calibration from a single scan at inference while keeping the foundation model fixed. Across two encoders and five SCORPION scanners, learned transfer reduces mean target-to-source embedding distance by 16.3-38.5% relative to raw embeddings. Comparisons with unrelated same-scanner controls reveal a positive same-slide contribution across all four evaluation settings, including scanner holdout. A source-anchored variant reduces source-feature displacement by 47.7-83.6% relative to learned transfer while retaining most of its alignment gain. By drawing calibration information from the slide itself, SlideRuler offers a path toward more consistent use of frozen pathology models across imaging systems.

Figures & tables

Appendix figures & tables11 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Sep 28, 2026cs.CV

HERO: Histology Encoder for Robust Representation in Oncology

Foundation models trained on large pathology image corpora now provide strong, transferable representations for computational pathology. Over the past few years a series of such models has been released, each trained on more slides than the last; on standard classification and segmentation benchmarks, the leading models are now separated by small margins. In clinical use, however, the foundation model is applied to images from hospitals, scanners, and staining protocols outside its training data. Encoders generally embed these acquisition factors alongside biological information, which may introduce downstream errors and hinder safe clinical adoption. A pathology foundation model should therefore be robust to acquisition shift without giving up representation quality, yet robustness is seldom the axis along which models are compared. In this report, we introduce HERO (Histology Encoder for Robust Representation in Oncology), a ViT-G/14 pathology foundation model trained with the DINO and iBOT objectives and refined with high-resolution Gram anchoring on a morphology-balanced corpus of 500 million tiles from approximately 575,000 clinical whole-slide images. Across the evaluated public benchmarks, HERO shows the strongest robustness to center, scanner, and stain variation among the compared state-of-the-art foundation models, performs comparably on tile-level classification, segmentation, and gene-expression prediction, ranks first on average across 39 evaluated slide-level clinical tasks, and, under an equal-weighted framework-level analysis, has the best average rank across the six benchmark frameworks.
Jul 24, 2026cs.CV

Robustifying pathology foundation models via fine-tuning

Pathology foundation models (FMs) produce powerful tile-level representations which remain sensitive to scanner and staining variability, undermining deployment across laboratories. We develop a novel fine-tuning recipe that improves the robustness of pathology FMs to acquisition factors. Applied to ten different FMs, our fine-tuning strategy consistently improves robustness for every model as well as downstream performance, with no observed trade-off. On average, it raises the PathoROB robustness index by 23% (from 0.72 to 0.87) and increases the overall cross-benchmark performance by 43% on Patho-Bench, HEST and THUNDER combined, with individual gains reaching up to 72% in robustness (Phikon-v2) and 76% in performance (Midnight-12k). We publicly release the fine-tuned versions of Phikon-v2 (Phaet) and Midnight-12k (Mascaret) at https://huggingface.co/wearewaiv/models.
Jun 9, 2026cs.CV

From Patches to Patients: A study of the tile-to-slide performance transferability in Digital Pathology

Foundation Models (FMs) have recently redefined the state-of-the-art in histopathology by providing robust representations for whole-slide image (WSI) analysis. However, selecting the optimal foundation model (FM) for a specific clinical cohort currently requires multiple preprocessing steps, followed by computationally expensive feature extraction and the training of a Multiple Instance Learning (MIL) aggregator for every model. In this work, we investigate whether efficient tile-level linear probing can serve as a reliable proxy for slide-level performance, reducing the need to run full slide-level pipelines for every candidate encoder. We benchmark 19 state-of-the-art FMs on 42 slide-level and 16 tile-level tasks, comparing tile probing metrics against slide-level outcomes using ABMIL and Mean Pooling aggregations. We observe a high correlation between tile and slide performance across varying task difficulties, indicating that encoder representation quality is the primary determinant of WSI success. Sensitivity analyses show that transferability is stable across models and is more influenced by cohort sizes and numbers of tiles per slide than by average task difficulty. We also measure the agreement in best performing models between tile and slide-level tasks, showing tile benchmarks reliably shortlist strong candidates. Overall, our study indicates that tile-level benchmarking provides an efficient and practical first step for narrowing down candidate models, while slide-level evaluation remains essential for final validation on clinical tasks.