cs.ROOct 8, 2026

Selectively Actuated Fiberbots for High-precision Minimally Invasive Surgery

Authors: Jinshi Zhao, Libaihe Tian, Alex Ranne, Qindong Zheng, Yue Li, Xiaotong Guo, Ziqi Yang, Ali Anil Demircali, +4 more

Organizations: Department of Metabolism, Digestion and Reproduction, Imperial College London, SW7 2AZ, UK · Hamlyn Centre for Robotic Surgery, Imperial College London, SW7 2AZ, UK · Department of Bioengineering, Imperial College London, SW7 2AZ, UK · Department of Biomedical Engineering, University of Glasgow, G12 8QQ, UK

Abstract

Long, slender instruments are essential for minimally invasive surgery (MIS), but achieving precise distal manipulation becomes increasingly difficult when actuation extends along the entire instrument. Here, we present an electrothermally actuated fiber-based robot designed for MIS procedures, in which Joule heating is concentrated in the distal active segment. The fiber is fabricated using a thermal drawing process and uses embedded metallic wires for thermal actuation. This robotic fiber, 1.9 mm in diameter and 1.2 m in length, can precisely manipulate surgical laser fibers with positional precision below 100 μμm. The compact size of the fiber robot allows it to pass through the working channel of a flexible endoscope, while keeping both devices mechanically uncoupled to allow independent motion. A phantom demonstration combining the robotic fiber with a da Vinci instrument conceptually demonstrated its compatibility with existing endoscopic systems for clinical applications. Our robotic fiber enables precise distal motion and holds the potential to improve clinical outcomes by enhancing precision in MIS procedures.

Figures & tables

Explore similar work

Sep 22, 2026

Design and Modeling of a Single-Port Three-Arm Robotic Tool for Minimally Invasive Neurosurgery

Surgical robots require highly dexterous and compact robotic systems capable of operating effectively within confined anatomical spaces. However, due to limited access provided by a single incision, the miniaturization and maneuverability of these robots still need to be improved. In this paper, we propose the design and modeling of a single-port three-arm robotic tool containing one major cannula (7.14 mm outer diameter (OD)) and three steerable minor cannulas (1.93 mm OD). By integrating the proposed 12 degrees-of-freedom (DoFs) steerable robotic tool with a 7-DoF robotic arm, this robotic system can potentially achieve multi-arm manipulation capability. We present the design of the steerable robotic tool consisting of tendon-driven joints controlled by a compact actuation system, derive the kinematic model, and validate both the static and kinematic models through experiments. The performance is evaluated with the root mean square error (RMSE) and mean absolute error (MAE) computed between the experimental data and the kinematic model.
May 29, 2026

Shaft-integrated Force Sensing with Transformer-based Dynamics Compensation for Telesurgery

Robot-Assisted Minimally Invasive Surgery (RAMIS) enhances surgeon dexterity, with newer platforms leveraging haptic feedback to further improve performance. Such force information has broader potential to inform performance assessment, tactile localization, and surgical autonomy. This motivates the need for accessible approaches to integrating force sensing into RAMIS tools. This work presents a method for integrating a six-axis commercial force sensor into the distal end of a standard cable-driven surgical instrument, enabling end-effector force measurement while preserving the original mechanical functionality of the device. The proposed design emphasizes reproducibility and accessibility for research applications, requiring no specialized manufacturing tools. A transformer neural network integrates force sensor measurements with robot state information to aid estimation of applied forces at the end-effector, compensating for internal cable forces arising from actuation. Our proposed approach achieved normalized errors below 6%, and generalized to unseen conditions better than purely proximal data-driven sensing approaches. High internal cable forces caused sensor saturation and reduced axial force observability, which can degrade performance along the tool's major axis and under higher load conditions. Given current levels of performance, the balance of system integrability and performance enables applications and research into timely topics of haptic feedback, skill assessment, and force-informed autonomy in RAMIS. Videos and code are available at https://enhanced-telerobotics.github.io/shaft_force_sensing/.
Jun 11, 2026

Low cost, easily manufactured, highly flexible strain and touch sensitive fiber for robotics applications

Existing stretch and touch sensors for robots are generally expensive with respect to at least one of material costs, required manufacturing equipment, or manufacturing time. We present and experimentally characterize a conductive fiber made using only inexpensive commercial off-the-shelf parts (conductive thread at 0.07/ft,siliconetubingat0.07/ft, silicone tubing at 0.94/ft) and tools (loop-style needle threader at $2), which can be manufactured quickly (20 cm length in 2 minutes.) We demonstrate its use as a resistive strain sensor with three applications: Triggering a grasp in a pneumatically actuated assistive finger, sensing the pose of a pneumatically actuated robotic strap, and estimating the pose of a flexible solid. We also demonstrate that it can be used as a capacitive sensor with two applications: First, as a touch sensor which triggers a commercial robot arm to move, and second, as a near-field sensor enabling the robot arm to follow a moving hand. The capacitive sensors are knitted, showcasing the high flexibility of the fiber. We discuss methods for improving manufacturing scalability and their cost trade-offs. Finally, we demonstrate a method for repairing a cut fiber.