cs.AIOct 11, 2026

ClinEdge: An Expert-Graded Benchmark of Real Patient Edge Cases Where Frontier Multimodal Models Fail

Authors: Anurag Sharma, Aditya Sharma, Sapna Baalwan

Organizations: Orthopaedic Surgeon · FutrBridge · Independent Researcher

Abstract

Most benchmarks for large language models in medicine are built from licensing examinations and theoretical questions. The few that draw on real clinical data do so only in part, and rarely require a model to read a patient's own imaging. ClinEdge addresses this gap with 32 real, de-identified patient cases from active clinical practice, each evaluated across seven frontier systems for a total of 224 expert-graded evaluations. Each case pairs primary imaging with a short vignette, contains a feature known to defeat pattern-matched reasoning, and is scored against the patient's documented clinical course. The suite is built for depth rather than volume. Grading followed a two-stage expert process. First, a senior orthopaedic surgeon graded all 224 responses on a weighted rubric and a pass-or-fail verdict. Second, a panel of nineteen physicians, largely senior specialists at teaching medical colleges, independently reviewed every case and every one of the 224 grades. All seven production systems were evaluated through their public interfaces, and all 224 conversations are preserved as replayable links. Performance was poor across all systems, and the failures were shared: different vendors missed the same findings and converged on the same wrong plans. From the experts' notes we catalogue 18 recurring failure modes in five families. The models stop reading an image at the first finding. They give generic plans and lean toward over-treatment. They trust a misleading history over correct imaging. Their answers vary across systems and runs, and change with question format. Failing answers were delivered fluently and without any expressed uncertainty. Four cases are released in full; the remaining 28 are held out, and we invite frontier AI labs and healthcare AI companies to evaluate their models against them ([email protected])

Explore similar work

Jun 26, 2026

IMCBench: A benchmark for multimodal LLMs in Image-grounded Medical Conversations

Recent advances in large language models and vision-language models have enabled reasoning over multimodal data, offering opportunities for clinical applications such as decision support and triaging. However, existing medical AI benchmarks are fragmented: some support multi-turn dialogues but lack images, while others provide multimodal inputs but focus on single-turn QA tasks. To address this gap, we introduce IMCBench, an image-grounded, multi-turn medical conversation benchmark that pairs real, publicly available clinical images with synthetic patient profiles to simulate realistic patient-clinician interactions. Each conversation is evaluated across three clinical dimensions: safety, accuracy, and appropriate use of uncertainty in diagnosis. We benchmark eight multimodal frontier models across four model families (Claude, GPT, Nova, and Llama), scoring each on a 1-5 scale using LLM-as-Jury scoring calibrated against expert clinician annotations. Our results show that Claude Opus 4.6 achieves the highest overall score (3.61), followed by Claude Sonnet 4.6 (3.30) and GPT-5.2 (3.29), though no model dominates all dimensions and safety degrades for both malignant and rare conditions (ΔΔ = -0.27 each). Ablation studies further reveal that both visual input and EHR context contribute to safe guidance (safety drops of 0.18 and 0.23 on average when each is removed), with stronger models leveraging visual features more effectively. Together, these findings demonstrate that accurate clinical description does not guarantee safe patient guidance, motivating the need for multi-dimensional evaluation frameworks in medical AI.
Jul 28, 2026

Evaluating Multi-Turn Multimodal Diagnostic Reasoning on Challenging Real-World Clinical Cases

Clinical diagnostic evaluation should not only assess whether models can provide correct diagnoses, but also reflect the realities of clinical practice, including progressive disclosure of multimodal information, dynamic updating of diagnostic hypotheses, and continuous refinement of clinical reasoning. However, existing evaluations of multimodal large language models (MLLMs) typically rely on single-turn or isolated tasks, making it difficult to fully capture the complexity of real-world clinical diagnosis. To bridge this gap, we developed ClinMM-Bench, the largest multi-turn multimodal clinical diagnostic evaluation benchmark to date. ClinMM-Bench contains 1,089 challenging real-world clinical cases and 3,760 medical images across eight specialties. We systematically evaluated 15 representative MLLMs using a two-level evaluation framework that assessed both diagnostic accuracy and diagnostic reasoning quality. Results showed that proprietary models achieved the highest overall diagnostic accuracy, but the proportion of completely correct diagnoses remained limited across all models. In terms of diagnostic reasoning quality, current models can identify plausible diagnostic directions but still have considerable limitations in generating reliable diagnostic reasoning. Error analysis further identified five representative failure modes: information synthesis failure, knowledge mapping error, perception error, premature closure, and visual hallucination.
Apr 14, 2026

Medical thinking with multiple images

Large language models perform well on many medical QA benchmarks, but real clinical reasoning often requires integrating evidence across multiple images rather than interpreting a single view. We introduce MedThinkVQA, an expert-annotated benchmark for thinking with multiple images, where models must interpret each image, combine cross-view evidence, and answer diagnostic questions with intermediate supervision and step-level evaluation. The dataset contains 8,067 cases, including 720 test cases, with an average of 6.62 images per case, substantially denser than prior work, whose expert-level benchmarks use at most 1.43 images per case. On the test set, the best closed-source models, Claude-4.6-Opus, Gemini-3-Pro, and GPT-5.2-xhigh, reach only 57.2%, 55.3%, and 54.9% accuracy, while GPT-5-mini and GPT-5-nano reach 39.7% and 30.8%. Strong open-source models lag behind, led by Qwen3.5-397B-A17B at 52.2% and Qwen3.5-27B at 50.6%. Further analysis identifies grounded multi-image reasoning as the main bottleneck: models often fail to extract, align, and compose evidence across views before higher-level inference can help. Providing expert single-image cues and cross-image summaries improves performance, whereas replacing them with self-generated intermediates reduces accuracy. Step-level analysis shows that over 70% of errors arise from image reading and cross-view integration. Scaling results further show that additional inference-time computation helps only when visual grounding is already reliable; when early evidence extraction is weak, longer reasoning yields limited or unstable gains and can amplify misread cues. These results suggest that the key challenge is not reasoning length alone, but reliable mechanisms for grounding, aligning, and composing distributed evidence across real-world multimodal clinical inputs.