cs.AIOct 13, 2026

ECG-RSI: Recursive Self-Improvement through Targeted Electrocardiogram Waveform Evolution

Authors: Xiaoliang Wang, Zhuo Chen, Chuanyang Zheng, Jiangwei Lao, Quanbin Wang, Honglin Lin, Jiajia Liu, Zhihong Lu, 

Organizations: Zhejiang University · Ant Group · Shanghai Artificial Intelligence Laboratory · Shanghai Jiao Tong University

Abstract

Electrocardiogram (ECG) models need supervision that targets evolving weaknesses and remains faithful to waveform evidence. We introduce ECG-RSI, a recursive self-improvement framework combining verified waveform synthesis with feedback-guided intervention search. Signal remeasurement verifies waveform edits; construction errors guide generator repair, while learner errors motivate interventions compared on a separate selection set. Across seven benchmarks, three rounds raise Qwen3.5-35B-A3B's mean question-answering accuracy from 34.57% to 56.04% and mean classification F1 from 24.27 to 34.03. Across the retained trajectory, the preferred supervision shifts from direct reinforcement to confusion-focused contrasts. Continued feedback correction yields diminishing external gains. These results motivate separating error diagnosis from intervention selection and checking whether gains on the feedback set transfer to independent benchmarks.

Figures & tables

Appendix figures & tables6 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Jul 27, 2026

Failures Reveal What Metrics Miss: An Evidence-Driven Agent for Recursive Refinement of ECG Classifiers

Deep models have substantially advanced 12-lead ECG classification, yet their refinement still relies heavily on human experts to inspect failures and iteratively revise classifier designs. Recent LLM-based agents have demonstrated the potential for automated model design, but when guided only by aggregate performance metrics, they lack insight into why individual cases fail and how the classifier should be revised. We present RecursiveECG, an evidence-driven LLM-as-Designer framework in which an LLM serves as an offline model designer that refines ECG classifiers based on concrete failures and objective ECG evidence. To ground failure diagnosis in executable evidence, Criteria-to-Measurement Compilation converts curated ECG criteria into validated deterministic functions that produce reproducible, reference-backed measurements for individual ECGs. Building on these measurements, Evidence-Grounded Failure Review analyzes failed and comparator cases by jointly considering raw waveforms, measurements, and model outputs, enabling the LLM to diagnose classifier limitations and formulate targeted revisions. Candidate revisions are executed and re-evaluated under a fixed problem contract, and only evidence-supported updates are retained. The resulting predictor is frozen after refinement and requires no LLM inference during deployment, while an audit trail links each accepted revision to its supporting evidence. Across PTB-XL, Georgia, and CPSC2018, RecursiveECG consistently outperforms strong baselines, achieving an average relative improvement of 10.0%. Extensive ablation and transfer studies further validate the effectiveness of its evidence-grounded refinement process.
Aug 31, 2026

ECGQuest: Benchmarking and Fine-Tuning Language Models for Electrocardiography

Electrocardiogram (ECG) interpretation requires knowledge of cardiology, electrophysiology, clinical diagnosis, ECG waveforms, signal acquisition, and instrumentation. Existing language-model benchmarks, however, primarily assess broad medical knowledge or interpretation of individual ECG signals and images rather than the broader contextual knowledge required for ECG interpretation. We developed ECGQuest, a literature-grounded resource for evaluating and fine-tuning ECG-specific language models. A GPT-4o-based pipeline generated questions from 23 ECG references and Computing in Cardiology proceedings from 2003-2025. The final dataset contains 10,904 unique True/False questions paired with their negated forms (21,808 Q&A pairs). We evaluated three commercial and 20 open-source language models on a held-out test set in a zero-shot setting. Five open-source models with 7-14B parameters were fine-tuned using Low-Rank Adaptation, with BERT and BiomedBERT included as supervised encoder baselines. Generalization was assessed on ECG-related subsets of MedMCQA and MedQA converted to binary True/False questions using official answer keys. Zero-shot accuracy on ECGQuest ranged from 49.5% to 74.4%, with GPT-5 performing best. General-purpose models outperformed medically specialized models, several models showed strong True/False bias, and encoder baselines performed near chance. Fine-tuning improved all open-source models by 6.5-14.1%. Fine-tuned DeepSeek-R1-Distill-Qwen-14B reached 76.3% accuracy, while a five-model voting ensemble reached 78.5%. On MedMCQA and MedQA, fine-tuning mainly benefited weaker or class-biased models and did not consistently improve strong base models. ECGQuest provides a reproducible benchmark for contextual ECG knowledge and shows that parameter-efficient fine-tuning can make smaller language models competitive with substantially larger commercial models.
Aug 13, 2026

The Impact of Temporal Context Length and Encoding Strategies on Self-Supervised ECG Representation Learning

Self-supervised electrocardiogram (ECG) models are often trained on a few seconds of ECG signal and, increasingly, on discretized token sequences. It remains unclear whether these choices sacrifice information needed for rhythm inference and longitudinal consistency in real-world ambulatory recordings. We present a controlled study on the Icentia11k single-lead dataset that varies (i) the input horizon (16 seconds, 1 minute, 5 minutes, and 10 minutes) and (ii) the front-end representation (continuous convolutional patch embeddings vs. fixed vector-quantized tokens), while holding the Transformer backbone and training protocol constant. Representations are assessed by downstream abnormal rhythm detection and by patient-level retrieval that probes cross-session stability. Our results show that increasing temporal context beyond 16-second snapshots yields stronger transfer and higher retrieval accuracy, with the strongest performance achieved by the 5- and 10-minute models, indicating improved capture of slow-varying rhythm dynamics and individual-specific structure. Across all evaluated horizons, continuous patch embeddings outperform discretized tokens, suggesting that quantization can discard clinically relevant waveform detail. These findings motivate ECG foundation models that emphasize extended context and continuous encoders for clinical prediction and similarity-based applications. Our code and pretrained models are publicly available at https://github.com/muha-0/ecg-ssl-representation-learning.