cs.CVOct 13, 2026

CryoTracer: A Synthetic-to-Real System for Filament Instance Tracing in Cryo-EM

Authors: Radosław Kuczbański, Wojciech Kozłowski, Mateusz Grzesiuk, Konrad Karanowski, Lukas Frey, Andrzej Rzepiela, Maciej Zięba

Organizations: WUST, Poland · ETH Zurich, Switzerland · Tooploox, Poland

Abstract

Particle picking in cryo-electron microscopy is commonly formulated as an object-detection problem in which individual particles are represented by bounding boxes, a natural representation for globular particles but a poor match for filaments that can extend across an entire micrograph. Existing methods reconstruct filament trajectories by linking local predictions in a separate post-processing stage, decoupling detection from instance formation and creating potential ambiguities at gaps and crossings. Directly preserving filament identity is particularly useful for polymorphic specimens, where segments originating from the same filament should remain associated. However, learning such instance-level representations is challenging because expert centerline annotations are scarce and costly to obtain. We introduce CryoTracer, a synthetic-to-real framework that addresses this limitation through procedural micrograph generation, transformer-based polyline prediction, and specimen-specific fine-tuning. Procedural pretraining exposes the model to diverse filament geometries, intersections, and imaging conditions before adaptation using a limited number of fully annotated experimental micrographs. CryoTracer represents filaments as ordered centerline polylines and optimizes their geometry using an orientation-invariant discrete Fréchet objective, enabling consistent learning regardless of tracing direction. Evaluation on established and newly expert-annotated datasets shows that CryoTracer improves instance-level filament recovery over existing particle-detection approaches. These results establish end-to-end polyline prediction as a practical alternative to detection-and-linking pipelines for recovering complete filament instances with limited micrograph annotation budgets. Code and data are available at https://github.com/cryotracer/cryotracer

Figures & tables

Appendix figures & tables12 assets

Supplementary material from the paper’s appendix.

Appendix

Explore similar work

Sep 8, 2026

FPicker: Topology-Guided Evolution for Filament Tracing in Low-SNR Microscopy

Automating filament tracing in Cryo-Electron Microscopy (Cryo-EM) is essential for 3D helical reconstruction but challenged by intersecting topologies and extremely low Signal-to-Noise Ratios (SNR=σs2/σn2\text{SNR} = σ_s^2/σ_n^2 < 0.1 or -10 dB). Existing paradigms fail: pixel-wise segmenters suffer from severe topological fracturing, box-based detectors face ghost center drift, sequential trackers derail due to error accumulation, and traditional active contours collapse under artificial closed-curve constraints. To resolve these bottlenecks, we present FPicker, the first topology-guided framework reconciling these incompatibilities. It unifies perception via a center-endpoint representation and an open-curve evolution module to explicitly model non-cyclic connectivity. On simulated benchmarks, FPicker outperforms top baselines by over 40%40\% relative gain in mean spatio-angular precision (mSAP) and reduces topological gap rates by over 60%60\% under extreme noise (−20 dB-20\text{ dB}). By learning intrinsic physical geometry rather than local texture, FPicker demonstrates strong potential as a resilient geometric backbone. Its zero-shot performance on the real-world EMPIAR dataset exhibits robust topological resistance, achieving a state-of-the-art 82.9% mSAP upon fine-tuning. Our results also suggest modeling physical priors is a highly robust path toward bridging the sim-to-real gap in signal-starved scientific imaging. The code is publicly available at: https://github.com/tomzhaosky/FPicker.
Aug 28, 2026

Reconstruction-Aware Cryo-EM Particle Picking

Cryo-electron microscopy (cryo-EM) determines the structures of proteins and macromolecular assemblies at near-atomic resolution, and the final 3D reconstruction depends on extracting a clean particle stack from noisy micrographs. This extraction decomposes into three sub-tasks, namely particle picking, contamination removal, and 2D class selection. Each of them, however, is trained and evaluated in isolation, and none is optimized for the reconstruction. We instead integrate the three sub-tasks into a single pipeline posed against downstream reconstruction quality. We instantiate the pipeline with a state-of-the-art component for each sub-task, CryoTransformer picking permissively, MicrographCleaner masking contamination, and CryoSift selecting 2D classes by a continuous quality score, and close the loop with a fine-tuning step that returns the surviving particles to the picker. The pipeline achieves a better 3D resolution than every picker we compare. We also show that the best 2D F1 is not the best resolution, so particle selection is better treated as one reconstruction-aware pipeline judged by the map it delivers.
Apr 20, 2026

Score-Based Matching with Target Guidance for Cryo-EM Denoising

Cryo-electron microscopy (cryo-EM) enables single-particle analysis of biological macromolecules under strict low-dose imaging conditions, but the resulting micrographs often exhibit extremely low signal-to-noise ratios and weak particle visibility. Image denoising is therefore an important preprocessing step for downstream cryo-EM analysis, including particle picking, 2D classification, and 3D reconstruction. Existing cryo-EM denoising methods are commonly trained with pixel-wise or Noise2Noise-style objectives, which can improve visual quality but do not explicitly account for structural consistency required by downstream analysis. In this work, we propose a score-based denoising framework for cryo-EM that learns the clean-data score to recover particle signals while better preserving structural information. Building on this formulation, we further introduce a target-guided variant that incorporates reference-density guidance to stabilize score learning under weak and ambiguous signal conditions. Rather than simply amplifying particle-like responses, our framework better suppresses structured low-frequency background, which improves particle--background separability for downstream analysis. Experiments on multiple cryo-EM datasets show that our score-based methods consistently improve downstream particle picking and produce more structure-consistent 3D reconstructions. Experiments on multiple cryo-EM datasets show that our methods improve downstream particle picking and produce more structure-consistent reconstructions.