cs.CVOct 14, 2026

Feasibility of a Patient-Specific Digital Twin for Ventriculoperitoneal Shunt Trajectory Planning

Authors: Kritsanavis Chongsrid, Vich Yindeedej, Supaporn Konmun, Xulei Yang, Si Yong Yeo

Organizations: MedVisAI Lab, Singapore. · Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore. · Centre of AI in Medicine, Singapore. · A*STAR Institute of Advanced Intelligence and Computing (A*STAR IAIC), Agency for Science, Technology and Research (A*STAR), Singapore. · 

Abstract

Catheter obstruction is the commonest cause of shunt failure; freehand insertion at Keen's point leaves the tip free in cerebrospinal fluid in only one case in ten. We built a digital twin that reconstructs skull, scalp, ear and ventricles from preoperative CT by deterministic geometry, searches every entry around Keen's point for the perpendicular trajectory with the longest intraventricular length under safety constraints, and returns the plan as two ruler measurements from the ear and two depths. Executed freehand in 11 consecutive adults (IDEAL Stage 2a), it achieved Hayhurst Grade 1 placement in 10 of 11 against 22 of 213 historically (p = 9 x 10^-9), median entry and angular deviations 2.5 mm and 5.9 degrees, 1.4 cm more intraventricular catheter than Keen's point, and no intraoperative complication. The technique was unchanged; the gain came from choosing entry and depth per patient. Whether it lowers revision is the next stage's hypothesis.

Explore similar work

Sep 30, 2026

An Uncertainty-Guided Digital Twin Framework for Online Adaptive Proton Therapy in Head and Neck Cancer: A Feasibility Study

Objective: Head and neck (HN) proton therapy spans six to seven weeks of anatomical change, while offline replanning takes about a week. We present an uncertainty-guided digital twin (UGDT) framework that forecasts treatment-day anatomy before treatment and evaluate whether it generates online adaptive proton therapy (APT) plans of clinical quality. Approach: A library of 302 longitudinal deformations from 88 previously treated HN patients was transported onto each new patient's treatment planning CT (TPCT) using two-step multi-atlas deformable image registration (DIR) built on a pretrained CT foundation model, generating about 284 predicted CTs (pdCTs) with contours per patient. Dispersion of propagated clinical target volume (CTV) contours defined a patient-specific robust margin. In ten patients, the quality assurance CT (QACT) triggering a replan represented treatment-day anatomy, and the physician-approved replan was the baseline. The pdCT most similar to the QACT (pdCT-H) and one from the lowest quartile (pdCT-L) were planned to within about 5% of baseline plan quality, forward-calculated on the QACT, and reoptimized to generate online APT plans. Main results: pdCT plans scored within -0.7% (pdCT-H) and -1.0% (pdCT-L) of baseline. Forward calculation on QACT reduced high-dose CTV D98% to 88.3% and 85.5%. After online reoptimization, D98% recovered to 98.3 +/- 0.3% and 98.2 +/- 0.3%, versus 98.5 +/- 0.4% at baseline. Spinal cord and brainstem doses remained below tolerance, and plan quality scores were within -1.1% (p = 0.19) and -1.7% (p = 0.01) of baseline. Significance: UGDT generated online APT plans comparable in quality to physician-approved offline replans using anatomy forecast before treatment, enabling a transition from reactive offline replanning toward anticipatory online adaptation.
Jul 2, 2026

Patient-Specific Articulated Digital Twins from a Single Full-Body CT Scan

Patient-specific anatomical models provide individualized context for surgical planning, image-guided intervention, and algorithm development. However, most CT-derived models are static: they preserve the body configuration captured at scan time, but cannot represent how the same anatomy would appear after patient repositioning. This limitation is especially important for radiographic imaging, where appearance depends jointly on imaging geometry and patient pose. We present a proof-of-concept for constructing a patient-specific articulated digital twin from a single full-body CT scan. The method fits a parametric human body model (SMPL) to obtain a patient-aligned kinematic scaffold, binds segmented bones and organs to an anatomy-aware rig, and retargets body-pose changes while preserving skeletal geometry. On three full-body CT subjects, the fitted scaffold achieved 15.8 ±\pm 4.0 mm chamfer distance and 95.9 ±\pm 1.8% skeletal enclosure. Recomposition at the acquisition pose preserved major radiographic structure, with overall SSIM of 0.872 ±\pm 0.016 and PSNR of 18.5 ±\pm 1.4 dB across paired DRRs. Across unseen target poses, the resulting twins enabled articulation while maintaining high skeletal enclosure (94.4 ±\pm 0.4%). As a feasibility demonstration, we render the articulated twin as pose-dependent DRRs. These results suggest the feasibility of extending static, view-controllable CT simulation toward pose-controllable anatomical twins for future synthetic imaging and positioning studies.
Sep 21, 2026

A digital-twin framework for forecasting treatment-day imaging with contour uncertainty in adaptive proton radiotherapy

Head-and-neck anatomy changes over a six-to-seven-week proton course, and the anatomy of a later week cannot be imaged when the plan is made. We present a digital-twin framework that forecasts a patient's treatment-day anatomy as an ensemble of predicted CTs with propagated contours and quantifies the uncertainty of the forecast contours. The twin is a library of previously treated patients with planning and weekly quality-assurance CTs (QACTs), made patient-specific by a two-step foundation-model deformable registration: a cross-patient field carries each library patient onto the current patient, and a longitudinal field, estimated in the current patient's frame, carries that patient's planning-to-QACT change onto the current patient's own planning CT. A library of 302 observations from 88 patients yields about 300 replicates per patient, each a deformation that occurred in a treated patient. The dispersion of the propagated contours, resolved by outward normal, is six-direction contour uncertainty in millimeters. This is uncertainty in the input to the forecast, which library patient the current patient follows, rather than in model parameters, and it is unchanged when the registration engine is exchanged. On ten patients with clinician contours on two QACTs, the library alone fixes the anisotropic shape of the uncertainty (4.5 to 6.2 mm); the first QACT narrows it by a factor of 3.2 to 3.6 without a contour being drawn; an approved contour improves the center but not the width. The estimate orders directions correctly but is not Gaussian-calibrated. A clinical target volume expansion is worked out as one application.