cs.CVOct 17, 2026

Hexagonal Basis Projectors for Model-Based Iterative CT Reconstruction

Authors: Ke Chen, Alireza Entezari

Organizations: University of Florida

Abstract

Image representation affects both the forward model and quantitative feature recovery in model-based iterative CT reconstruction. For isotropically bandlimited signals, the hexagonal lattice is the most sampling-efficient lattice in two dimensions, with greater directional isotropy and a larger alias-free bandwidth than the Cartesian grid at equal density. We develop constant and linear hexagonal projectors for two-dimensional fan-beam CT using box spline calculus. Both bases form a partition of unity on common coefficient centers; the linear tent also reproduces affine functions. We derive analytic ray footprints and effective detector-blur expressions and implement efficient GPU forward and backprojection. On simulated FORBILD data, the linear model improves on Cartesian and hexagonal pixels, with its best noisy-data accuracy at the coarser resolution. Real-world 2DeteCT comparisons use high-dose, high-resolution Cartesian reconstructions as pseudo ground truth and show competitive image and feature agreement. These results establish a practical hexagonal representation for quantitative CT.

Figures & tables

Explore similar work

Apr 2, 2026

FaCT-GS: Fast and Scalable CT Reconstruction with Gaussian Splatting

Gaussian Splatting (GS) has emerged as a dominating technique for image rendering and has quickly been adapted for the X-ray Computed Tomography (CT) reconstruction task. However, despite its growing popularity, the benefits of GS are typically not substantial enough to motivate a transition from well-established reconstruction algorithms. This paper addresses the most significant remaining limitations of the GS-based approach by introducing FaCT-GS, a framework for fast and flexible CT reconstruction. Enabled by an in-depth optimization of the voxelization and rasterization pipelines, our new method is significantly faster than its predecessors and scales well with projection and output volume size. Furthermore, the improved voxelization enables rapid fitting of Gaussians to pre-existing volumes, which can serve as a prior for warm-starting the reconstruction, or simply as an alternative, compressed representation. FaCT-GS is over 4X faster than the State of the Art GS CT reconstruction on standard 512x512 projections, and over 13X faster on 2k projections. Implementation and data available through: https://github.com/PaPieta/fact-gs.
Oct 27, 2026

EUReCA: End-to-End Unified CBCT Reconstruction Across Clinical Acquisitions

Cone-beam computed tomography (CBCT) is widely used for image-guided radiotherapy, but reducing the number of projections to lower dose and scan time makes reconstruction increasingly ill-posed. We present EUReCA (End-to-end Unified REconstruction across Clinical Acquisitions), a geometry-aware feed-forward model for variable-view clinical linac CBCT. For a given acquisition trajectory, EUReCA accepts 8-100 projections with a single set of weights, without view-count-specific retraining; the same architecture and training recipe extend unchanged to other clinical trajectories. It combines learned projection features with an in-frame Feldkamp-Davis-Kress (FDK) reconstruction. The model encodes each projection with a shared multiscale backbone, back-projects features into multiresolution 3D grids using the acquisition geometry, aggregates variable numbers of views at fixed computational cost, and refines the volume with a global 3D transformer and multilevel decoder. On simulated data, EUReCA achieved 29.9-33.2 dB PSNR with 10-100 views and outperformed all applicable feed-forward baselines; it also exceeded iterative optimization-based methods while running orders of magnitude faster. On 15 measured patient CBCT scans evaluated against vendor reconstructions, EUReCA achieved the best performance at every tested view count. These results suggest that geometry-aware, measurement-anchored feed-forward reconstruction can provide a practical and flexible foundation for variable-view linac CBCT.
Mar 16, 2026

ILV: Iterative Latent Volumes for Fast and Accurate Sparse-View CT Reconstruction

A long-term goal in CT imaging is to achieve fast and accurate 3D reconstruction from sparse-view projections, thereby reducing radiation exposure, lowering system cost, and enabling timely imaging in clinical workflows. Recent feed-forward approaches have shown strong potential toward this overarching goal, yet their results still suffer from artifacts and loss of fine details. In this work, we introduce Iterative Latent Volumes (ILV), a feed-forward framework that integrates data-driven priors with classical iterative reconstruction principles to overcome key limitations of prior feed-forward models in sparse-view CBCT reconstruction. At its core, ILV constructs an explicit 3D latent volume that is repeatedly updated by conditioning on multi-view X-ray features and the learned anatomical prior, enabling the recovery of fine structural details beyond the reach of prior feed-forward models. In addition, we develop and incorporate several key architectural components, including an X-ray feature volume, group cross-attention, efficient self-attention, and view-wise feature aggregation, that efficiently realize its core latent volume refinement concept. Extensive experiments on a large-scale dataset of approximately 14,000 CT volumes demonstrate that ILV significantly outperforms existing feed-forward and optimization-based methods in both reconstruction quality and speed. These results show that ILV enables fast and accurate sparse-view CBCT reconstruction suitable for clinical use. The project page is available at: https://sngryonglee.github.io/ILV/.