eess.SPOct 17, 2026

Is User Calibration Still Necessary for Continuous Myoelectric Control? A Closed-Loop Comparison of Calibration-Free Controllers

Authors: Amir Reza Hariri, Kevin B. Englehart, Erik Scheme

Organizations: Institute of Biomedical Engineering and the Department of Electrical and Computer Engineering, University of New Brunswick, Fredericton, NB E3B 5A3, Canada.

Abstract

The need for user-specific calibration remains an often-cited barrier to widespread adoption of myoelectric control. Cross-user models trained on large multi-user datasets can now recognize gestures from unseen users without calibration, but they have been evaluated almost exclusively offline, leaving open whether calibration is still needed in closed-loop control. This study compared six calibration-free controllers, trained on 306 users of the EMG-EPN-612 dataset and used without any calibration data from the test participant, against three calibrated controllers in a closed-loop Fitts' law target-acquisition task with sixteen participants. The calibrated controllers achieved higher offline balanced accuracy (90.6% against 73.1% for the best controller of each paradigm), but completion rates did not differ significantly between paradigms, and the highest completion rate was achieved by a calibration-free controller. Calibrated controllers moved faster on successful acquisitions, partly because of their individually fitted speed mappings, though not significantly after correction for multiple comparisons. However, every calibration-free controller produced more direct and stable trajectories than every calibrated controller, even after adjusting for cursor speed. Offline accuracy did not predict completion rate across controllers or within participants, and across paradigms higher offline accuracy was associated with poorer trajectory quality in 15 of 16 participants. Without any calibration data from the end user, a model trained across a large population matched calibrated control in completion rate and exceeded it in trajectory quality. The offline accuracy gained through calibration should therefore not be taken as evidence of a closed-loop benefit.

Figures & tables

Explore similar work

Jul 30, 2026

A Montage-Agnostic Encoder for Calibration-Light Cross-User Gesture Recognition from Surface Electromyography

Pattern-recognition control promises a myoelectric prosthesis that responds to many intended gestures rather than one or two, but the promise has stayed in the laboratory. A recogniser trained on one person rarely transfers to the next, and useful performance usually demands a fresh round of labelled calibration from the end user. A montage-agnostic encoder is introduced that reads each electrode with shared weights and locates it by its physical coordinate rather than its index, so one architecture ingests any channel count without montage-specific parameters. Trained across users, it exceeds a per-user Hudgins and linear-discriminant classifier by 0.234 macro-F1 on DB1 for every held-out subject and by 0.108 on DB2, and falls below it on the ten-subject DB5. Each of the encoder's three key components individually accounts for more than half of its 3-shot macro F1 in an otherwise budget-matched ablation study. A controlled subject-count sweep shows the margin is close to flat from nine training subjects to thirty-nine, so the training pool binds only as a stability floor below which cross-user training fails to converge; what tracks the direction of the comparison across the three databases is instead the strength of the per-user baseline, which signal fidelity sets. Comparing against an LDA baseline depends on budget spent training models and on how good that baseline is, and self-supervised pretraining had no benefits once a supervised model was adequately trained.
Jul 30, 2026

Recognition and Label-Free Adaptation Across Recording Sessions in Surface-EMG Gesture Decoding

Recognition accuracy obtained during a recording session does not persist when a user puts on the electrodes again after the electrodes had previously been removed. The electrodes may have moved slightly, the skin may be drier or wetter, or the elbow may be positioned differently; these factors all contribute to day-to-day variability and therefore represent a major obstacle to implementing successful pattern-recognition based myoelectric control systems in daily practice. However, simply recalibrating a user's hand for 20 min at every doff/don event is a clearly unrealistic expectation. A montage-agnostic encoder built for cross-user, cross-montage transfer is trained here using data collected during a particular recording session, and then applied to data collected later in a different recording session without adjusting anything, on the ten intact subjects of NinaPro DB6. The performance of this approach is compared to that of a per-user LDA classification pipeline, and to that of two published approaches that only rely on source data collected from the same recording session. Carried unchanged across recording sessions, the encoder retains 0.688 macro-F1 against 0.540 for the per-user pipeline, and, on the per-window metric the published baselines use, sits above both published source-only results, a band of two points that locates the encoder rather than ranking it. Of five label-free test-time adaptations, only feature-statistic alignment improves every subject; batch-normalisation re-estimation, a standard method in the domain-adaptation literature, collapses this architecture entirely. Aligning the encoder's feature statistics to the new session recovers about what a single labelled calibration repetition would.
Sep 28, 2026

Separating personal from population gains when calibrating EEG foundation models for new users

Foundation models are increasingly adapted to individual users, but an apparent personalization gain can simply reflect a stronger population model. This distinction matters for brain-computer interfaces, where every new user must be calibrated. We evaluated personal adaptation of three frozen EEG foundation models (CBraMod, REVE and LaBraM) in 235 held-out subjects from three motor-imagery datasets, comparing each subject's adapter with the population model and with adapters fitted to other subjects. Using all first-half session labels, personal adapters improved mean balanced accuracy over the population model by 1.5-5.4 percentage points and outperformed exchanged adapters by 2.3-7.3 points in all nine model-dataset combinations. The size of this benefit depended on population training: with four times the original budget, median gains remained positive (1.0-2.0 points) but were smaller for every model, and no population model reached a confirmed plateau. Acquiring the benefit cheaply was unreliable: few-label calibration was consistently non-negative on only one dataset, and in CBraMod neither unlabeled context nor meta-learned initialization outperformed matched controls. Personalization should therefore be evaluated against both a population reference and exchanged parameters, across population-training budgets.