PCXR-Copilot: Device-aware pediatric chest radiographic analysis with segmentation, suppression, and edema-related cues

Authors: Xueyang Li, Alec Girten, Peng Zeng, Mingze Jiang, Shaoyang Huang, Gelei Xu, Danny Z. Chen, Yiyu Shi, 

Organizations: Department of Computer Science and Engineering, University of Notre Dame, Notre Dame, IN, USA. · Department of Cardiology, Boston Children’s Hospital, Boston, MA, USA. · Department of Pediatrics, Harvard Medical School, Boston, MA, USA. · School of Computing and Information, University of Pittsburgh, Pittsburgh, PA, USA.

Abstract

Patients admitted to pediatric ICU and cardiac ICU often require intensive perioperative support and frequent chest radiography to monitor support devices, extravascular lung water, and body-wall edema. Radiographic interpretation and analysis is often difficult due to superimposed anatomic and iatrogenic structures that obscure clinically relevant signals. While deep learning can provide decision support, translation to pediatric radiographs is still limited by high device burden and scarcity of pediatric datasets with clinically grounded device annotations. To address this gap, we first introduce PediaDeviceSeg-1K, a curated dataset of 1,000 anterior-posterior radiographs of pediatric CICU patients with clinically grounded, fine-grained annotations of common ICU devices. To our best knowledge, this is the first publicly available pediatric CICU CXR resource with clinically grounded device annotations for device-focused benchmarking. Building on PediaDeviceSeg-1K, we further present PCXR-Copilot, a device-aware pipeline that outputs lung and device masks, optional device-suppressed views, and edema-related visualization maps and scalar indices. The full pipeline has been integrated and runs in real time within the TWIST platform at Boston Children's Hospital, demonstrating feasibility for real-world clinical deployment.

Figures & tables

Explore similar work

Sep 4, 2026

Cross-dataset transportability of pediatric chest X-ray deep learning across three countries: discrimination, calibration, operating-point failure, and limited-label recovery

Background and Objective: External evaluation of medical-imaging AI is often collapsed into discrimination. We evaluated a computational protocol that separately tests discrimination, probability calibration, fixed operatingpoint transport, shortcut-associated signal, and limited-label recoverability for pediatric pneumonia classification across datasets from three countries. Methods: After exact-duplicate removal, 5,824 Guangzhou radiographs supported leakage-controlled source development and internal testing. A frozen three-seed DenseNet121 dual-view ensemble was evaluated zero-shot on BDCXR-3257 from Bangladesh (n = 3, 257) and an untouched harmonized VinDr-PCXR/PediCXR test cohort from Vietnam (n = 1, 077). Matched seed-42 variants tested architectural robustness. Secondary BDCXR analyses used a fixed 651-image adaptation pool and 2,606-image hold-out; 163, 326, and 651 labels represented 5%, 10%, and 20% of complete BDCXR. Results: Internal AUROC was 0.976 with 95.1% sensitivity. BDCXR and VinDr-PCXR AUROC were 0.798 and 0.742, while frozen-threshold sensitivity fell to 6.2% and 0%. Source-to-BDCXR AUROC degradation occurred for a full-image baseline (0.961 to 0.749), ungated dual-view model (0.977 to 0.766), and gated MixStyle model (0.966 to 0.789). With 163 BDCXR labels, Platt recalibration preserved AUROC while increasing held-out sensitivity to 88.3%, but specificity was 47.9% and the alert rate was 78.5%. Two hundred repeated 163-label fits confirmed sensitivity recovery but substantial specificity variability. Conclusions: Cross-dataset shifts across countries affected ranking, probability alignment, and source-defined decision behavior differently. Transport studies should evaluate these components separately and quantify the operational burden of apparent recovery.
Jun 1, 2026

PaCX-MAE: Physiology-Augmented Chest X-Ray Masked Autoencoder

Clinical diagnosis often requires combining imaging with physiological measurements, yet deployed models typically operate on unimodal data. We present PaCX-MAE, a cross-modal distillation framework that injects physiological priors into chest X-ray (CXR) encoders while remaining strictly unimodal at inference. PaCX-MAE augments in-domain masked autoencoding with a dual contrastive-predictive objective, aligning CXR representations with paired ECG and laboratory embeddings. Extensive evaluation across nine benchmarks demonstrates consistent improvements over domain-specific MAE, particularly on physiology-dependent tasks (e.g., +2.7 AUROC on MedMod; +6.5 F1 on VinDr). The method proves highly label-efficient in the 1% regime and preserves anatomical fidelity, achieving parity with MAE on segmentation tasks. Zero-shot and attention analyses confirm that PaCX-MAE successfully learns to attend to physiological indicators, such as the cardiac silhouette, absent in standard visual pretraining.
Oct 21, 2026

APED-CXR: Adaptive Privileged Evidence Distillation for Chest X-Ray Grounding with Image-Only Inference

Compact chest X-ray (CXR) models that localize findings suit deployment, but box annotations are limited and report-aware multimodal models are expensive at inference. We introduce APED-CXR, which distills report-informed spatial evidence from a frozen multimodal teacher into a student with 11.1M parameters that predicts diseases and boxes from shared evidence maps and requires the image alone at test time. During training, the teacher uses the radiograph, report, and queried class to evaluate regions proposed from the student's current evidence maps, and its support scores serve as training targets for the student's pooled evidence scores within these regions. Trained on PadChest and evaluated on held-out PadChest-GR, refreshing the student's proposals for teacher evaluation improves box-level localization F1 from 0.302 with fixed warm-up proposals to 0.338 (IoU >= 0.5; gain 0.036, 95% CI [0.022, 0.049]), while maintaining diagnostic AUC. This gain depends on the teacher checking current proposals: with equally many random boxes, a fixed dense box set, teacher-generated boxes, or report rules instead of the teacher, F1 stays near the fixed-proposal level, and proposals two refreshes old recover only part of the gain. On NIH ChestX-ray14, a secondary test set, box recall also rises from 0.423 to 0.447.